Movement Disorders (revue)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Spiral analysis: a new technique for measuring tremor with a digitizing tablet.

Identifieur interne : 004325 ( PubMed/Corpus ); précédent : 004324; suivant : 004326

Spiral analysis: a new technique for measuring tremor with a digitizing tablet.

Auteurs : S L Pullman

Source :

RBID : pubmed:9827601

English descriptors

Abstract

A new computational method for quantification of tremor and other aspects of motor dysfunction is described. By using a digitizing tablet connected to a microcomputer, this analysis is derived from the handwritten Archimedean spiral. This technique extends the standard clinical neurologic test of spiral drawing into an objective and accurate measure that can automatically detect, characterize, and quantify motor dysfunction in patients with movement disorders. Further, it is safe, inexpensive, fast, portable, noninvasive, and can be administered to a large cohort of patients without the need for wires or other attachments. Spiral data are collected in the X, Y, and pressure axes, providing virtual "triaxial" recordings. Spiral analysis is shown to be capable of assessing subtle motor abnormalities potentially indicative of clinical problems in their earliest stages, and thus allow the most rational forms of genetic testing, treatment, or prevention. Spiral analysis may be useful as an initial marker of clinical involvement or serve as an objective gauge of change after therapeutic intervention.

PubMed: 9827601

Links to Exploration step

pubmed:9827601

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Spiral analysis: a new technique for measuring tremor with a digitizing tablet.</title>
<author>
<name sortKey="Pullman, S L" sort="Pullman, S L" uniqKey="Pullman S" first="S L" last="Pullman">S L Pullman</name>
<affiliation>
<nlm:affiliation>Department of Neurology, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1998">1998</date>
<idno type="RBID">pubmed:9827601</idno>
<idno type="pmid">9827601</idno>
<idno type="wicri:Area/PubMed/Corpus">004325</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Spiral analysis: a new technique for measuring tremor with a digitizing tablet.</title>
<author>
<name sortKey="Pullman, S L" sort="Pullman, S L" uniqKey="Pullman S" first="S L" last="Pullman">S L Pullman</name>
<affiliation>
<nlm:affiliation>Department of Neurology, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Movement disorders : official journal of the Movement Disorder Society</title>
<idno type="ISSN">0885-3185</idno>
<imprint>
<date when="1998" type="published">1998</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Diagnosis, Computer-Assisted</term>
<term>Humans</term>
<term>Models, Theoretical</term>
<term>Tremor (diagnosis)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Tremor</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Diagnosis, Computer-Assisted</term>
<term>Humans</term>
<term>Models, Theoretical</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A new computational method for quantification of tremor and other aspects of motor dysfunction is described. By using a digitizing tablet connected to a microcomputer, this analysis is derived from the handwritten Archimedean spiral. This technique extends the standard clinical neurologic test of spiral drawing into an objective and accurate measure that can automatically detect, characterize, and quantify motor dysfunction in patients with movement disorders. Further, it is safe, inexpensive, fast, portable, noninvasive, and can be administered to a large cohort of patients without the need for wires or other attachments. Spiral data are collected in the X, Y, and pressure axes, providing virtual "triaxial" recordings. Spiral analysis is shown to be capable of assessing subtle motor abnormalities potentially indicative of clinical problems in their earliest stages, and thus allow the most rational forms of genetic testing, treatment, or prevention. Spiral analysis may be useful as an initial marker of clinical involvement or serve as an objective gauge of change after therapeutic intervention.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">9827601</PMID>
<DateCreated>
<Year>1999</Year>
<Month>03</Month>
<Day>22</Day>
</DateCreated>
<DateCompleted>
<Year>1999</Year>
<Month>03</Month>
<Day>22</Day>
</DateCompleted>
<DateRevised>
<Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0885-3185</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>13 Suppl 3</Volume>
<PubDate>
<Year>1998</Year>
</PubDate>
</JournalIssue>
<Title>Movement disorders : official journal of the Movement Disorder Society</Title>
<ISOAbbreviation>Mov. Disord.</ISOAbbreviation>
</Journal>
<ArticleTitle>Spiral analysis: a new technique for measuring tremor with a digitizing tablet.</ArticleTitle>
<Pagination>
<MedlinePgn>85-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>A new computational method for quantification of tremor and other aspects of motor dysfunction is described. By using a digitizing tablet connected to a microcomputer, this analysis is derived from the handwritten Archimedean spiral. This technique extends the standard clinical neurologic test of spiral drawing into an objective and accurate measure that can automatically detect, characterize, and quantify motor dysfunction in patients with movement disorders. Further, it is safe, inexpensive, fast, portable, noninvasive, and can be administered to a large cohort of patients without the need for wires or other attachments. Spiral data are collected in the X, Y, and pressure axes, providing virtual "triaxial" recordings. Spiral analysis is shown to be capable of assessing subtle motor abnormalities potentially indicative of clinical problems in their earliest stages, and thus allow the most rational forms of genetic testing, treatment, or prevention. Spiral analysis may be useful as an initial marker of clinical involvement or serve as an objective gauge of change after therapeutic intervention.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Pullman</LastName>
<ForeName>S L</ForeName>
<Initials>SL</Initials>
<AffiliationInfo>
<Affiliation>Department of Neurology, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>Mov Disord</MedlineTA>
<NlmUniqueID>8610688</NlmUniqueID>
<ISSNLinking>0885-3185</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D003936">Diagnosis, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008962">Models, Theoretical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014202">Tremor</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1998</Year>
<Month>11</Month>
<Day>25</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1998</Year>
<Month>11</Month>
<Day>25</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1998</Year>
<Month>11</Month>
<Day>25</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">9827601</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004325 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 004325 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    MovDisordV3
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:9827601
   |texte=   Spiral analysis: a new technique for measuring tremor with a digitizing tablet.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:9827601" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a MovDisordV3 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Sun Jul 3 12:29:32 2016. Site generation: Wed Feb 14 10:52:30 2024