Movement Disorders (revue)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A novel automatic method for monitoring Tourette motor tics through a wearable device.

Identifieur interne : 001673 ( PubMed/Corpus ); précédent : 001672; suivant : 001674

A novel automatic method for monitoring Tourette motor tics through a wearable device.

Auteurs : Michel Bernabei ; Ezio Preatoni ; Martin Mendez ; Luca Piccini ; Mauro Porta ; Giuseppe Andreoni

Source :

RBID : pubmed:20669298

English descriptors

Abstract

The aim of this study was to propose a novel automatic method for quantifying motor-tics caused by the Tourette Syndrome (TS). In this preliminary report, the feasibility of the monitoring process was tested over a series of standard clinical trials in a population of 12 subjects affected by TS. A wearable instrument with an embedded three-axial accelerometer was used to detect and classify motor tics during standing and walking activities. An algorithm was devised to analyze acceleration data by: eliminating noise; detecting peaks connected to pathological events; and classifying intensity and frequency of motor tics into quantitative scores. These indexes were compared with the video-based ones provided by expert clinicians, which were taken as the gold-standard. Sensitivity, specificity, and accuracy of tic detection were estimated, and an agreement analysis was performed through the least square regression and the Bland-Altman test. The tic recognition algorithm showed sensitivity = 80.8% ± 8.5% (mean ± SD), specificity = 75.8% ± 17.3%, and accuracy = 80.5% ± 12.2%. The agreement study showed that automatic detection tended to overestimate the number of tics occurred. Although, it appeared this may be a systematic error due to the different recognition principles of the wearable and video-based systems. Furthermore, there was substantial concurrency with the gold-standard in estimating the severity indexes. The proposed methodology gave promising performances in terms of automatic motor-tics detection and classification in a standard clinical context. The system may provide physicians with a quantitative aid for TS assessment. Further developments will focus on the extension of its application to everyday long-term monitoring out of clinical environments.

DOI: 10.1002/mds.23188
PubMed: 20669298

Links to Exploration step

pubmed:20669298

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A novel automatic method for monitoring Tourette motor tics through a wearable device.</title>
<author>
<name sortKey="Bernabei, Michel" sort="Bernabei, Michel" uniqKey="Bernabei M" first="Michel" last="Bernabei">Michel Bernabei</name>
<affiliation>
<nlm:affiliation>Dipartimento di Bioingegneria, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Preatoni, Ezio" sort="Preatoni, Ezio" uniqKey="Preatoni E" first="Ezio" last="Preatoni">Ezio Preatoni</name>
</author>
<author>
<name sortKey="Mendez, Martin" sort="Mendez, Martin" uniqKey="Mendez M" first="Martin" last="Mendez">Martin Mendez</name>
</author>
<author>
<name sortKey="Piccini, Luca" sort="Piccini, Luca" uniqKey="Piccini L" first="Luca" last="Piccini">Luca Piccini</name>
</author>
<author>
<name sortKey="Porta, Mauro" sort="Porta, Mauro" uniqKey="Porta M" first="Mauro" last="Porta">Mauro Porta</name>
</author>
<author>
<name sortKey="Andreoni, Giuseppe" sort="Andreoni, Giuseppe" uniqKey="Andreoni G" first="Giuseppe" last="Andreoni">Giuseppe Andreoni</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="doi">10.1002/mds.23188</idno>
<idno type="RBID">pubmed:20669298</idno>
<idno type="pmid">20669298</idno>
<idno type="wicri:Area/PubMed/Corpus">001673</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A novel automatic method for monitoring Tourette motor tics through a wearable device.</title>
<author>
<name sortKey="Bernabei, Michel" sort="Bernabei, Michel" uniqKey="Bernabei M" first="Michel" last="Bernabei">Michel Bernabei</name>
<affiliation>
<nlm:affiliation>Dipartimento di Bioingegneria, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Preatoni, Ezio" sort="Preatoni, Ezio" uniqKey="Preatoni E" first="Ezio" last="Preatoni">Ezio Preatoni</name>
</author>
<author>
<name sortKey="Mendez, Martin" sort="Mendez, Martin" uniqKey="Mendez M" first="Martin" last="Mendez">Martin Mendez</name>
</author>
<author>
<name sortKey="Piccini, Luca" sort="Piccini, Luca" uniqKey="Piccini L" first="Luca" last="Piccini">Luca Piccini</name>
</author>
<author>
<name sortKey="Porta, Mauro" sort="Porta, Mauro" uniqKey="Porta M" first="Mauro" last="Porta">Mauro Porta</name>
</author>
<author>
<name sortKey="Andreoni, Giuseppe" sort="Andreoni, Giuseppe" uniqKey="Andreoni G" first="Giuseppe" last="Andreoni">Giuseppe Andreoni</name>
</author>
</analytic>
<series>
<title level="j">Movement disorders : official journal of the Movement Disorder Society</title>
<idno type="eISSN">1531-8257</idno>
<imprint>
<date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Monitoring, Ambulatory (instrumentation)</term>
<term>Monitoring, Ambulatory (methods)</term>
<term>Sensitivity and Specificity</term>
<term>Severity of Illness Index</term>
<term>Tics (diagnosis)</term>
<term>Tics (physiopathology)</term>
<term>Tourette Syndrome (diagnosis)</term>
<term>Tourette Syndrome (physiopathology)</term>
<term>Video Recording</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Tics</term>
<term>Tourette Syndrome</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Monitoring, Ambulatory</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Monitoring, Ambulatory</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Tics</term>
<term>Tourette Syndrome</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Sensitivity and Specificity</term>
<term>Severity of Illness Index</term>
<term>Video Recording</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to propose a novel automatic method for quantifying motor-tics caused by the Tourette Syndrome (TS). In this preliminary report, the feasibility of the monitoring process was tested over a series of standard clinical trials in a population of 12 subjects affected by TS. A wearable instrument with an embedded three-axial accelerometer was used to detect and classify motor tics during standing and walking activities. An algorithm was devised to analyze acceleration data by: eliminating noise; detecting peaks connected to pathological events; and classifying intensity and frequency of motor tics into quantitative scores. These indexes were compared with the video-based ones provided by expert clinicians, which were taken as the gold-standard. Sensitivity, specificity, and accuracy of tic detection were estimated, and an agreement analysis was performed through the least square regression and the Bland-Altman test. The tic recognition algorithm showed sensitivity = 80.8% ± 8.5% (mean ± SD), specificity = 75.8% ± 17.3%, and accuracy = 80.5% ± 12.2%. The agreement study showed that automatic detection tended to overestimate the number of tics occurred. Although, it appeared this may be a systematic error due to the different recognition principles of the wearable and video-based systems. Furthermore, there was substantial concurrency with the gold-standard in estimating the severity indexes. The proposed methodology gave promising performances in terms of automatic motor-tics detection and classification in a standard clinical context. The system may provide physicians with a quantitative aid for TS assessment. Further developments will focus on the extension of its application to everyday long-term monitoring out of clinical environments.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">20669298</PMID>
<DateCreated>
<Year>2010</Year>
<Month>09</Month>
<Day>14</Day>
</DateCreated>
<DateCompleted>
<Year>2010</Year>
<Month>12</Month>
<Day>28</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1531-8257</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>25</Volume>
<Issue>12</Issue>
<PubDate>
<Year>2010</Year>
<Month>Sep</Month>
<Day>15</Day>
</PubDate>
</JournalIssue>
<Title>Movement disorders : official journal of the Movement Disorder Society</Title>
<ISOAbbreviation>Mov. Disord.</ISOAbbreviation>
</Journal>
<ArticleTitle>A novel automatic method for monitoring Tourette motor tics through a wearable device.</ArticleTitle>
<Pagination>
<MedlinePgn>1967-72</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1002/mds.23188</ELocationID>
<Abstract>
<AbstractText>The aim of this study was to propose a novel automatic method for quantifying motor-tics caused by the Tourette Syndrome (TS). In this preliminary report, the feasibility of the monitoring process was tested over a series of standard clinical trials in a population of 12 subjects affected by TS. A wearable instrument with an embedded three-axial accelerometer was used to detect and classify motor tics during standing and walking activities. An algorithm was devised to analyze acceleration data by: eliminating noise; detecting peaks connected to pathological events; and classifying intensity and frequency of motor tics into quantitative scores. These indexes were compared with the video-based ones provided by expert clinicians, which were taken as the gold-standard. Sensitivity, specificity, and accuracy of tic detection were estimated, and an agreement analysis was performed through the least square regression and the Bland-Altman test. The tic recognition algorithm showed sensitivity = 80.8% ± 8.5% (mean ± SD), specificity = 75.8% ± 17.3%, and accuracy = 80.5% ± 12.2%. The agreement study showed that automatic detection tended to overestimate the number of tics occurred. Although, it appeared this may be a systematic error due to the different recognition principles of the wearable and video-based systems. Furthermore, there was substantial concurrency with the gold-standard in estimating the severity indexes. The proposed methodology gave promising performances in terms of automatic motor-tics detection and classification in a standard clinical context. The system may provide physicians with a quantitative aid for TS assessment. Further developments will focus on the extension of its application to everyday long-term monitoring out of clinical environments.</AbstractText>
<CopyrightInformation>© 2010 Movement Disorder Society.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Bernabei</LastName>
<ForeName>Michel</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Dipartimento di Bioingegneria, Politecnico di Milano, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Preatoni</LastName>
<ForeName>Ezio</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mendez</LastName>
<ForeName>Martin</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Piccini</LastName>
<ForeName>Luca</ForeName>
<Initials>L</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Porta</LastName>
<ForeName>Mauro</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Andreoni</LastName>
<ForeName>Giuseppe</ForeName>
<Initials>G</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Mov Disord</MedlineTA>
<NlmUniqueID>8610688</NlmUniqueID>
<ISSNLinking>0885-3185</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000293">Adolescent</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018670">Monitoring, Ambulatory</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012680">Sensitivity and Specificity</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012720">Severity of Illness Index</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020323">Tics</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000503">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005879">Tourette Syndrome</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000503">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014741">Video Recording</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2010</Year>
<Month>7</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2010</Year>
<Month>7</Month>
<Day>30</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2010</Year>
<Month>12</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="doi">10.1002/mds.23188</ArticleId>
<ArticleId IdType="pubmed">20669298</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001673 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001673 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    MovDisordV3
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:20669298
   |texte=   A novel automatic method for monitoring Tourette motor tics through a wearable device.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:20669298" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a MovDisordV3 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Sun Jul 3 12:29:32 2016. Site generation: Wed Feb 14 10:52:30 2024