Movement Disorders (revue)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.

Identifieur interne : 000195 ( Ncbi/Merge ); précédent : 000194; suivant : 000196

Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.

Auteurs : E D Louis [États-Unis] ; E. Yousefzadeh ; L F Barnes ; Q. Yu ; S L Pullman ; K J Wendt

Source :

RBID : pubmed:10634247

English descriptors

Abstract

An important part of epidemiologic and genetic studies of essential tremor (ET) is an assessment of tremor severity. Clinical rating scales are semiquantitative and computerized tremor analysis, available at tertiary medical centers, is not transportable into the field. As part of an epidemiologic study, we modified the Klove-Matthews Motor Steadiness Battery, collecting objective quantitative data on tremor severity in patients with ET and control subjects.

PubMed: 10634247

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:10634247

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.</title>
<author>
<name sortKey="Louis, E D" sort="Louis, E D" uniqKey="Louis E" first="E D" last="Louis">E D Louis</name>
<affiliation wicri:level="4">
<nlm:affiliation>Department of Neurology and the Gertrude H. Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Neurology and the Gertrude H. Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, NY</wicri:regionArea>
<placeName>
<region type="state">État de New York</region>
<settlement type="city">New York</settlement>
</placeName>
<orgName type="university">Université Columbia</orgName>
</affiliation>
</author>
<author>
<name sortKey="Yousefzadeh, E" sort="Yousefzadeh, E" uniqKey="Yousefzadeh E" first="E" last="Yousefzadeh">E. Yousefzadeh</name>
</author>
<author>
<name sortKey="Barnes, L F" sort="Barnes, L F" uniqKey="Barnes L" first="L F" last="Barnes">L F Barnes</name>
</author>
<author>
<name sortKey="Yu, Q" sort="Yu, Q" uniqKey="Yu Q" first="Q" last="Yu">Q. Yu</name>
</author>
<author>
<name sortKey="Pullman, S L" sort="Pullman, S L" uniqKey="Pullman S" first="S L" last="Pullman">S L Pullman</name>
</author>
<author>
<name sortKey="Wendt, K J" sort="Wendt, K J" uniqKey="Wendt K" first="K J" last="Wendt">K J Wendt</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2000">2000</date>
<idno type="RBID">pubmed:10634247</idno>
<idno type="pmid">10634247</idno>
<idno type="wicri:Area/PubMed/Corpus">004056</idno>
<idno type="wicri:Area/PubMed/Curation">004056</idno>
<idno type="wicri:Area/PubMed/Checkpoint">003E40</idno>
<idno type="wicri:Area/Ncbi/Merge">000195</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.</title>
<author>
<name sortKey="Louis, E D" sort="Louis, E D" uniqKey="Louis E" first="E D" last="Louis">E D Louis</name>
<affiliation wicri:level="4">
<nlm:affiliation>Department of Neurology and the Gertrude H. Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Neurology and the Gertrude H. Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, NY</wicri:regionArea>
<placeName>
<region type="state">État de New York</region>
<settlement type="city">New York</settlement>
</placeName>
<orgName type="university">Université Columbia</orgName>
</affiliation>
</author>
<author>
<name sortKey="Yousefzadeh, E" sort="Yousefzadeh, E" uniqKey="Yousefzadeh E" first="E" last="Yousefzadeh">E. Yousefzadeh</name>
</author>
<author>
<name sortKey="Barnes, L F" sort="Barnes, L F" uniqKey="Barnes L" first="L F" last="Barnes">L F Barnes</name>
</author>
<author>
<name sortKey="Yu, Q" sort="Yu, Q" uniqKey="Yu Q" first="Q" last="Yu">Q. Yu</name>
</author>
<author>
<name sortKey="Pullman, S L" sort="Pullman, S L" uniqKey="Pullman S" first="S L" last="Pullman">S L Pullman</name>
</author>
<author>
<name sortKey="Wendt, K J" sort="Wendt, K J" uniqKey="Wendt K" first="K J" last="Wendt">K J Wendt</name>
</author>
</analytic>
<series>
<title level="j">Movement disorders : official journal of the Movement Disorder Society</title>
<idno type="ISSN">0885-3185</idno>
<imprint>
<date when="2000" type="published">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Diagnosis, Computer-Assisted (instrumentation)</term>
<term>Electromyography (instrumentation)</term>
<term>Epidemiologic Studies</term>
<term>Equipment Design</term>
<term>Essential Tremor (diagnosis)</term>
<term>Essential Tremor (epidemiology)</term>
<term>Essential Tremor (genetics)</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Motor Skills</term>
<term>Neurologic Examination (instrumentation)</term>
<term>Signal Processing, Computer-Assisted (instrumentation)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Essential Tremor</term>
</keywords>
<keywords scheme="MESH" qualifier="epidemiology" xml:lang="en">
<term>Essential Tremor</term>
</keywords>
<keywords scheme="MESH" qualifier="genetics" xml:lang="en">
<term>Essential Tremor</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Diagnosis, Computer-Assisted</term>
<term>Electromyography</term>
<term>Neurologic Examination</term>
<term>Signal Processing, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Epidemiologic Studies</term>
<term>Equipment Design</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Motor Skills</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">An important part of epidemiologic and genetic studies of essential tremor (ET) is an assessment of tremor severity. Clinical rating scales are semiquantitative and computerized tremor analysis, available at tertiary medical centers, is not transportable into the field. As part of an epidemiologic study, we modified the Klove-Matthews Motor Steadiness Battery, collecting objective quantitative data on tremor severity in patients with ET and control subjects.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">10634247</PMID>
<DateCreated>
<Year>2000</Year>
<Month>02</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted>
<Year>2000</Year>
<Month>02</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2007</Year>
<Month>11</Month>
<Day>14</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0885-3185</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>15</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2000</Year>
<Month>Jan</Month>
</PubDate>
</JournalIssue>
<Title>Movement disorders : official journal of the Movement Disorder Society</Title>
<ISOAbbreviation>Mov. Disord.</ISOAbbreviation>
</Journal>
<ArticleTitle>Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.</ArticleTitle>
<Pagination>
<MedlinePgn>95-102</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">An important part of epidemiologic and genetic studies of essential tremor (ET) is an assessment of tremor severity. Clinical rating scales are semiquantitative and computerized tremor analysis, available at tertiary medical centers, is not transportable into the field. As part of an epidemiologic study, we modified the Klove-Matthews Motor Steadiness Battery, collecting objective quantitative data on tremor severity in patients with ET and control subjects.</AbstractText>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To describe the modified Klove-Matthews Motor Steadiness Battery, validate this test battery against several other measures of tremor severity, demonstrate test-retest reliability, and provide standard reference values for normal control subjects and patients with ET who undergo this test battery.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Patients with ET and control subjects, ascertained from both a clinic and a community, underwent a standardized evaluation including a demographic and medical questionnaire, tremor disability questionnaire, videotaped tremor examination, performance-based test, modified Klove-Matthews Motor Steadiness Battery (Groove-Type Steadiness Tester [GTST] and Nine-Hole Steadiness Tester [NHST]), and quantitative computerized tremor analysis.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There were 19 patients with ET and 28 control subjects. NHST and GTST total scores were correlated significantly with the tremor disability questionnaire score (r = 0.63, p = 0.001 and r = 0.49, p = 0.016), total tremor score (tremor examination, r = 0.68, p<0.001 and r = 0.41, p = 0.005), performance-based test score (r = 0.81, p<0.001 and r = 0.65, p = 0.001), and quantitative computerized tremor analysis results (for example, spiral drawing, r = 0.62, p = 0.01 and r = 0.58, p = 0.019). Test-retest reliability was generally high (r = 0.79-0.94, p<0.001).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The modified Klove-Matthews Motor Steadiness Battery provides a reliable and valid means to collect objective quantitative data on tremor severity. Rapidity of administration and ease of transport make it a potentially useful tool in epidemiologic and genetic field studies.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Louis</LastName>
<ForeName>E D</ForeName>
<Initials>ED</Initials>
<AffiliationInfo>
<Affiliation>Department of Neurology and the Gertrude H. Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, NY, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Yousefzadeh</LastName>
<ForeName>E</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Barnes</LastName>
<ForeName>L F</ForeName>
<Initials>LF</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Yu</LastName>
<ForeName>Q</ForeName>
<Initials>Q</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Pullman</LastName>
<ForeName>S L</ForeName>
<Initials>SL</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Wendt</LastName>
<ForeName>K J</ForeName>
<Initials>KJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>NS01863</GrantID>
<Acronym>NS</Acronym>
<Agency>NINDS NIH HHS</Agency>
<Country>United States</Country>
</Grant>
<Grant>
<GrantID>RR00645</GrantID>
<Acronym>RR</Acronym>
<Agency>NCRR NIH HHS</Agency>
<Country>United States</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
<PublicationType UI="D013487">Research Support, U.S. Gov't, P.H.S.</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>UNITED STATES</Country>
<MedlineTA>Mov Disord</MedlineTA>
<NlmUniqueID>8610688</NlmUniqueID>
<ISSNLinking>0885-3185</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D003936">Diagnosis, Computer-Assisted</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004576">Electromyography</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D016021">Epidemiologic Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004867">Equipment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D020329">Essential Tremor</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000175">diagnosis</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000453">epidemiology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000235">genetics</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009048">Motor Skills</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D009460">Neurologic Examination</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012815">Signal Processing, Computer-Assisted</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000295">instrumentation</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2000</Year>
<Month>1</Month>
<Day>14</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2000</Year>
<Month>1</Month>
<Day>14</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2000</Year>
<Month>1</Month>
<Day>14</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">10634247</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>État de New York</li>
</region>
<settlement>
<li>New York</li>
</settlement>
<orgName>
<li>Université Columbia</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="Barnes, L F" sort="Barnes, L F" uniqKey="Barnes L" first="L F" last="Barnes">L F Barnes</name>
<name sortKey="Pullman, S L" sort="Pullman, S L" uniqKey="Pullman S" first="S L" last="Pullman">S L Pullman</name>
<name sortKey="Wendt, K J" sort="Wendt, K J" uniqKey="Wendt K" first="K J" last="Wendt">K J Wendt</name>
<name sortKey="Yousefzadeh, E" sort="Yousefzadeh, E" uniqKey="Yousefzadeh E" first="E" last="Yousefzadeh">E. Yousefzadeh</name>
<name sortKey="Yu, Q" sort="Yu, Q" uniqKey="Yu Q" first="Q" last="Yu">Q. Yu</name>
</noCountry>
<country name="États-Unis">
<region name="État de New York">
<name sortKey="Louis, E D" sort="Louis, E D" uniqKey="Louis E" first="E D" last="Louis">E D Louis</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000195 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000195 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    MovDisordV3
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:10634247
   |texte=   Validation of a portable instrument for assessing tremor severity in epidemiologic field studies.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:10634247" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a MovDisordV3 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Sun Jul 3 12:29:32 2016. Site generation: Wed Feb 14 10:52:30 2024