Imaging of subthalamic nucleus and ventralis intermedius of the thalamus.
Identifieur interne : 000768 ( Ncbi/Checkpoint ); précédent : 000767; suivant : 000769Imaging of subthalamic nucleus and ventralis intermedius of the thalamus.
Auteurs : Alim Louis Benabid [France] ; Adnan Koudsie ; Abdelhamid Benazzouz ; Jean-François Le Bas ; Pierre PollakSource :
- Movement disorders : official journal of the Movement Disorder Society [ 0885-3185 ] ; 2002.
English descriptors
- KwdEn :
- Cerebral Ventriculography, Electric Stimulation Therapy, Electrodes, Implanted, Humans, Magnetic Resonance Imaging, Movement Disorders (surgery), Stereotaxic Techniques, Subthalamic Nucleus (pathology), Subthalamic Nucleus (radiography), Subthalamic Nucleus (surgery), Thalamus (pathology), Thalamus (radiography), Thalamus (surgery), Tomography, X-Ray Computed, Ventral Thalamic Nuclei (pathology), Ventral Thalamic Nuclei (radiography), Ventral Thalamic Nuclei (surgery).
- MESH :
- pathology : Subthalamic Nucleus, Thalamus, Ventral Thalamic Nuclei.
- radiography : Subthalamic Nucleus, Thalamus, Ventral Thalamic Nuclei.
- surgery : Movement Disorders, Subthalamic Nucleus, Thalamus, Ventral Thalamic Nuclei.
- Cerebral Ventriculography, Electric Stimulation Therapy, Electrodes, Implanted, Humans, Magnetic Resonance Imaging, Stereotaxic Techniques, Tomography, X-Ray Computed.
Abstract
The techniques of targeting the subthalamic nucleus (STN) and the ventralis intermedius nucleus (Vim) are similar, only the coordinates are different. Targeting ideally consists of gathering all data about a target and positioning the electrode correctly within that target. The electrode should be positioned within a statistical range of coordinates, where the neuronal firing fits a given pattern and responds to external stimuli, particularly to proprioceptive inputs, in a somatotopically organized manner. Moreover, final placement should provide the best clinical improvement of symptoms under the stimulation parameters expected to be used in the long term. This latter criterion is by far the most important, because intraoperative findings indicate the functional benefit for the patient, which is the ultimate purpose of this surgery. A variety of radiological modalities are available to provide data for electrode placement, but each type has its drawbacks. Ventriculography, although safe when performed accordingly to strict technical procedure, is the most precise method but provides more indirect targeting and is more invasive than magnetic resonance imaging (MRI). MRI is the best method for visualizing the STN and, to some extent, for discerning the Vim, but it is plagued with unpredictable and nonreproducible deformations that induce a systematic distortion. These shortcomings no doubt will be corrected in the near future, and the technologies will better assist us in the proper placement of electrodes, which will provide the patient with the highest possible benefit.
PubMed: 11948766
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 003A83
- to stream PubMed, to step Curation: 003A83
- to stream PubMed, to step Checkpoint: 003A63
- to stream Ncbi, to step Merge: 000768
- to stream Ncbi, to step Curation: 000768
Links to Exploration step
pubmed:11948766Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Imaging of subthalamic nucleus and ventralis intermedius of the thalamus.</title>
<author><name sortKey="Benabid, Alim Louis" sort="Benabid, Alim Louis" uniqKey="Benabid A" first="Alim Louis" last="Benabid">Alim Louis Benabid</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Clinical and Biological Neurosciences, Institut National de la Santé et de la Recherche Médicale, Preclinical Neurosciences U-318, Joseph Fourier University of Grenoble, Hôpital A. Michallon, France. Alim-Louis.Benabid@ujf-grenoble.fr</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Clinical and Biological Neurosciences, Institut National de la Santé et de la Recherche Médicale, Preclinical Neurosciences U-318, Joseph Fourier University of Grenoble, Hôpital A. Michallon</wicri:regionArea>
<wicri:noRegion>Hôpital A. Michallon</wicri:noRegion>
<wicri:noRegion>Hôpital A. Michallon</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Koudsie, Adnan" sort="Koudsie, Adnan" uniqKey="Koudsie A" first="Adnan" last="Koudsie">Adnan Koudsie</name>
</author>
<author><name sortKey="Benazzouz, Abdelhamid" sort="Benazzouz, Abdelhamid" uniqKey="Benazzouz A" first="Abdelhamid" last="Benazzouz">Abdelhamid Benazzouz</name>
</author>
<author><name sortKey="Le Bas, Jean Francois" sort="Le Bas, Jean Francois" uniqKey="Le Bas J" first="Jean-François" last="Le Bas">Jean-François Le Bas</name>
</author>
<author><name sortKey="Pollak, Pierre" sort="Pollak, Pierre" uniqKey="Pollak P" first="Pierre" last="Pollak">Pierre Pollak</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:11948766</idno>
<idno type="pmid">11948766</idno>
<idno type="wicri:Area/PubMed/Corpus">003A83</idno>
<idno type="wicri:Area/PubMed/Curation">003A83</idno>
<idno type="wicri:Area/PubMed/Checkpoint">003A63</idno>
<idno type="wicri:Area/Ncbi/Merge">000768</idno>
<idno type="wicri:Area/Ncbi/Curation">000768</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000768</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Imaging of subthalamic nucleus and ventralis intermedius of the thalamus.</title>
<author><name sortKey="Benabid, Alim Louis" sort="Benabid, Alim Louis" uniqKey="Benabid A" first="Alim Louis" last="Benabid">Alim Louis Benabid</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Clinical and Biological Neurosciences, Institut National de la Santé et de la Recherche Médicale, Preclinical Neurosciences U-318, Joseph Fourier University of Grenoble, Hôpital A. Michallon, France. Alim-Louis.Benabid@ujf-grenoble.fr</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Clinical and Biological Neurosciences, Institut National de la Santé et de la Recherche Médicale, Preclinical Neurosciences U-318, Joseph Fourier University of Grenoble, Hôpital A. Michallon</wicri:regionArea>
<wicri:noRegion>Hôpital A. Michallon</wicri:noRegion>
<wicri:noRegion>Hôpital A. Michallon</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Koudsie, Adnan" sort="Koudsie, Adnan" uniqKey="Koudsie A" first="Adnan" last="Koudsie">Adnan Koudsie</name>
</author>
<author><name sortKey="Benazzouz, Abdelhamid" sort="Benazzouz, Abdelhamid" uniqKey="Benazzouz A" first="Abdelhamid" last="Benazzouz">Abdelhamid Benazzouz</name>
</author>
<author><name sortKey="Le Bas, Jean Francois" sort="Le Bas, Jean Francois" uniqKey="Le Bas J" first="Jean-François" last="Le Bas">Jean-François Le Bas</name>
</author>
<author><name sortKey="Pollak, Pierre" sort="Pollak, Pierre" uniqKey="Pollak P" first="Pierre" last="Pollak">Pierre Pollak</name>
</author>
</analytic>
<series><title level="j">Movement disorders : official journal of the Movement Disorder Society</title>
<idno type="ISSN">0885-3185</idno>
<imprint><date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Cerebral Ventriculography</term>
<term>Electric Stimulation Therapy</term>
<term>Electrodes, Implanted</term>
<term>Humans</term>
<term>Magnetic Resonance Imaging</term>
<term>Movement Disorders (surgery)</term>
<term>Stereotaxic Techniques</term>
<term>Subthalamic Nucleus (pathology)</term>
<term>Subthalamic Nucleus (radiography)</term>
<term>Subthalamic Nucleus (surgery)</term>
<term>Thalamus (pathology)</term>
<term>Thalamus (radiography)</term>
<term>Thalamus (surgery)</term>
<term>Tomography, X-Ray Computed</term>
<term>Ventral Thalamic Nuclei (pathology)</term>
<term>Ventral Thalamic Nuclei (radiography)</term>
<term>Ventral Thalamic Nuclei (surgery)</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Subthalamic Nucleus</term>
<term>Thalamus</term>
<term>Ventral Thalamic Nuclei</term>
</keywords>
<keywords scheme="MESH" qualifier="radiography" xml:lang="en"><term>Subthalamic Nucleus</term>
<term>Thalamus</term>
<term>Ventral Thalamic Nuclei</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Movement Disorders</term>
<term>Subthalamic Nucleus</term>
<term>Thalamus</term>
<term>Ventral Thalamic Nuclei</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Cerebral Ventriculography</term>
<term>Electric Stimulation Therapy</term>
<term>Electrodes, Implanted</term>
<term>Humans</term>
<term>Magnetic Resonance Imaging</term>
<term>Stereotaxic Techniques</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The techniques of targeting the subthalamic nucleus (STN) and the ventralis intermedius nucleus (Vim) are similar, only the coordinates are different. Targeting ideally consists of gathering all data about a target and positioning the electrode correctly within that target. The electrode should be positioned within a statistical range of coordinates, where the neuronal firing fits a given pattern and responds to external stimuli, particularly to proprioceptive inputs, in a somatotopically organized manner. Moreover, final placement should provide the best clinical improvement of symptoms under the stimulation parameters expected to be used in the long term. This latter criterion is by far the most important, because intraoperative findings indicate the functional benefit for the patient, which is the ultimate purpose of this surgery. A variety of radiological modalities are available to provide data for electrode placement, but each type has its drawbacks. Ventriculography, although safe when performed accordingly to strict technical procedure, is the most precise method but provides more indirect targeting and is more invasive than magnetic resonance imaging (MRI). MRI is the best method for visualizing the STN and, to some extent, for discerning the Vim, but it is plagued with unpredictable and nonreproducible deformations that induce a systematic distortion. These shortcomings no doubt will be corrected in the near future, and the technologies will better assist us in the proper placement of electrodes, which will provide the patient with the highest possible benefit.</div>
</front>
</TEI>
<affiliations><list><country><li>France</li>
</country>
</list>
<tree><noCountry><name sortKey="Benazzouz, Abdelhamid" sort="Benazzouz, Abdelhamid" uniqKey="Benazzouz A" first="Abdelhamid" last="Benazzouz">Abdelhamid Benazzouz</name>
<name sortKey="Koudsie, Adnan" sort="Koudsie, Adnan" uniqKey="Koudsie A" first="Adnan" last="Koudsie">Adnan Koudsie</name>
<name sortKey="Le Bas, Jean Francois" sort="Le Bas, Jean Francois" uniqKey="Le Bas J" first="Jean-François" last="Le Bas">Jean-François Le Bas</name>
<name sortKey="Pollak, Pierre" sort="Pollak, Pierre" uniqKey="Pollak P" first="Pierre" last="Pollak">Pierre Pollak</name>
</noCountry>
<country name="France"><noRegion><name sortKey="Benabid, Alim Louis" sort="Benabid, Alim Louis" uniqKey="Benabid A" first="Alim Louis" last="Benabid">Alim Louis Benabid</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000768 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 000768 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= MovDisordV3 |flux= Ncbi |étape= Checkpoint |type= RBID |clé= pubmed:11948766 |texte= Imaging of subthalamic nucleus and ventralis intermedius of the thalamus. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i -Sk "pubmed:11948766" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a MovDisordV3
This area was generated with Dilib version V0.6.23. |