Movement Disorders (revue)

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease treated with subthalamic deep brain stimulation

Identifieur interne : 000398 ( Istex/Curation ); précédent : 000397; suivant : 000399

Effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease treated with subthalamic deep brain stimulation

Auteurs : Anna Lena Törnqvist [Suède] ; Lucyna Schalén ; Stig Rehncrona [Suède]

Source :

RBID : ISTEX:0A3C1AFB213A551379C7EC5631C8CCCE519875A4

English descriptors

Abstract

We evaluated the effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease (PD) bilaterally treated with deep brain stimulation (DBS) in the subthalamic nucleus (STN). Ten patients treated with DBS for 15 ± 5 months (mean, SD) with significant (P < 0.01) symptom reduction (Unified Parkinson's Disease Rating Scale III) were included. In the medication off condition, video laryngostroboscopy was performed and then, in random order, 11 DBS parameter settings were tested. Amplitude was increased and decreased by 25%, frequency was varied in the range 70 to 185 pps, and each of the contacts was tested separately as a cathode. The patients read a standard running text and five nonsense sentences per setting. A listener panel transcribed the nonsense sentences as perceived and valued the quality of speech on a visual analogue scale. With the patients' normally used settings, there was no significant (P = 0.058) group difference between DBS OFF and ON, but in four patients the intelligibility deteriorated with DBS ON. The higher frequencies or increased amplitude caused significant (P < 0.02) impairments of intelligibility, whereas changing the polarity between the separate contacts did not. The settings of amplitude and frequency have a major influence on the intelligibility of speech, emphasizing the importance of meticulous parameter adjustments when programming DBS to minimize side effects related to speech. © 2004 Movement Disorder Society

Url:
DOI: 10.1002/mds.20348

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:0A3C1AFB213A551379C7EC5631C8CCCE519875A4

Curation

No country items

Lucyna Schalén
<affiliation>
<mods:affiliation>Department of Logopedics, Phoneatrics, and Audiology, University Hospital, Lund Sweden</mods:affiliation>
<wicri:noCountry code="subField">Lund Sweden</wicri:noCountry>
</affiliation>

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease treated with subthalamic deep brain stimulation</title>
<author>
<name sortKey="Tornqvist, Anna Lena" sort="Tornqvist, Anna Lena" uniqKey="Tornqvist A" first="Anna Lena" last="Törnqvist">Anna Lena Törnqvist</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Neurosurgery, University Hospital, Lund, Sweden</mods:affiliation>
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Neurosurgery, University Hospital, Lund</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Schalen, Lucyna" sort="Schalen, Lucyna" uniqKey="Schalen L" first="Lucyna" last="Schalén">Lucyna Schalén</name>
<affiliation>
<mods:affiliation>Department of Logopedics, Phoneatrics, and Audiology, University Hospital, Lund Sweden</mods:affiliation>
<wicri:noCountry code="subField">Lund Sweden</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Rehncrona, Stig" sort="Rehncrona, Stig" uniqKey="Rehncrona S" first="Stig" last="Rehncrona">Stig Rehncrona</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Neurosurgery, University Hospital, Lund, Sweden</mods:affiliation>
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Neurosurgery, University Hospital, Lund</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:0A3C1AFB213A551379C7EC5631C8CCCE519875A4</idno>
<date when="2005" year="2005">2005</date>
<idno type="doi">10.1002/mds.20348</idno>
<idno type="url">https://api.istex.fr/document/0A3C1AFB213A551379C7EC5631C8CCCE519875A4/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000398</idno>
<idno type="wicri:Area/Istex/Curation">000398</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease treated with subthalamic deep brain stimulation</title>
<author>
<name sortKey="Tornqvist, Anna Lena" sort="Tornqvist, Anna Lena" uniqKey="Tornqvist A" first="Anna Lena" last="Törnqvist">Anna Lena Törnqvist</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Neurosurgery, University Hospital, Lund, Sweden</mods:affiliation>
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Neurosurgery, University Hospital, Lund</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Schalen, Lucyna" sort="Schalen, Lucyna" uniqKey="Schalen L" first="Lucyna" last="Schalén">Lucyna Schalén</name>
<affiliation>
<mods:affiliation>Department of Logopedics, Phoneatrics, and Audiology, University Hospital, Lund Sweden</mods:affiliation>
<wicri:noCountry code="subField">Lund Sweden</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Rehncrona, Stig" sort="Rehncrona, Stig" uniqKey="Rehncrona S" first="Stig" last="Rehncrona">Stig Rehncrona</name>
<affiliation wicri:level="1">
<mods:affiliation>Department of Neurosurgery, University Hospital, Lund, Sweden</mods:affiliation>
<country xml:lang="fr">Suède</country>
<wicri:regionArea>Department of Neurosurgery, University Hospital, Lund</wicri:regionArea>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Movement Disorders</title>
<title level="j" type="abbrev">Mov. Disord.</title>
<idno type="ISSN">0885-3185</idno>
<idno type="eISSN">1531-8257</idno>
<imprint>
<publisher>Wiley Subscription Services, Inc., A Wiley Company</publisher>
<pubPlace>Hoboken</pubPlace>
<date type="published" when="2005-04">2005-04</date>
<biblScope unit="vol">20</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="416">416</biblScope>
<biblScope unit="page" to="423">423</biblScope>
</imprint>
<idno type="ISSN">0885-3185</idno>
</series>
<idno type="istex">0A3C1AFB213A551379C7EC5631C8CCCE519875A4</idno>
<idno type="DOI">10.1002/mds.20348</idno>
<idno type="ArticleID">MDS20348</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0885-3185</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Parkinson's disease</term>
<term>deep brain stimulation</term>
<term>nucleus subthalamicus</term>
<term>speech</term>
<term>video laryngostroboscopy</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We evaluated the effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease (PD) bilaterally treated with deep brain stimulation (DBS) in the subthalamic nucleus (STN). Ten patients treated with DBS for 15 ± 5 months (mean, SD) with significant (P < 0.01) symptom reduction (Unified Parkinson's Disease Rating Scale III) were included. In the medication off condition, video laryngostroboscopy was performed and then, in random order, 11 DBS parameter settings were tested. Amplitude was increased and decreased by 25%, frequency was varied in the range 70 to 185 pps, and each of the contacts was tested separately as a cathode. The patients read a standard running text and five nonsense sentences per setting. A listener panel transcribed the nonsense sentences as perceived and valued the quality of speech on a visual analogue scale. With the patients' normally used settings, there was no significant (P = 0.058) group difference between DBS OFF and ON, but in four patients the intelligibility deteriorated with DBS ON. The higher frequencies or increased amplitude caused significant (P < 0.02) impairments of intelligibility, whereas changing the polarity between the separate contacts did not. The settings of amplitude and frequency have a major influence on the intelligibility of speech, emphasizing the importance of meticulous parameter adjustments when programming DBS to minimize side effects related to speech. © 2004 Movement Disorder Society</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/MovDisordV3/Data/Istex/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000398 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Curation/biblio.hfd -nk 000398 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    MovDisordV3
   |flux=    Istex
   |étape=   Curation
   |type=    RBID
   |clé=     ISTEX:0A3C1AFB213A551379C7EC5631C8CCCE519875A4
   |texte=   Effects of different electrical parameter settings on the intelligibility of speech in patients with Parkinson's disease treated with subthalamic deep brain stimulation
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Sun Jul 3 12:29:32 2016. Site generation: Wed Feb 14 10:52:30 2024