The fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers.
Identifieur interne : 000B95 ( Ncbi/Checkpoint ); précédent : 000B94; suivant : 000B96The fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers.
Auteurs : C N Mcewen [États-Unis] ; W J Simonsick ; B S Larsen ; K. Ute ; K. HatadaSource :
- Journal of the American Society for Mass Spectrometry [ 1044-0305 ] ; 1995.
Abstract
Electrospray ionization (ESI) is capable of ionizing many soluble polymers. The ESI spectra are complex because of overlap of the multiply charged ions of the oligomer distribution, causing current computer transform programs to fail. However, it is possible to determine the origin of the multiply charged ions, making it feasible to write a program designed to transform ESI polymer spectra. To assess the value of such a program for polymer analysis, isolated monodisperse methyl methacrylate (MMA) oligomers (25 and 50 repeat units) were used to determine molar signal response and propensity for fragmentation.The sum of the peak areas for the multiply charged MMA 50-mer was found to be only about 66% of the summed peak areas for the 25-mer for the same molar concentration. However, conversion of the multiply charged peak areas to the singly charged representations, with peak area compression taken into account, gave equal signal responses for the 25-and 50-mers. Signal response variations due to the tacticity of the MMA oligomers were not observed. Fragmentation of the MMA oligomers also was shown not to occur under normal ESI conditions. Therefore, transformation of the polymer spectra to the singly charged molecular ion distribution should allow accurate calculation of average molecular weights, polydispersity, end group mass, and repeat unit mass.
DOI: 10.1016/1044-0305(95)00476-T
PubMed: 24214034
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 002799
- to stream PubMed, to step Curation: 002799
- to stream PubMed, to step Checkpoint: 002650
- to stream Ncbi, to step Merge: 000B95
- to stream Ncbi, to step Curation: 000B95
Links to Exploration step
pubmed:24214034Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers.</title>
<author><name sortKey="Mcewen, C N" sort="Mcewen, C N" uniqKey="Mcewen C" first="C N" last="Mcewen">C N Mcewen</name>
<affiliation wicri:level="2"><nlm:affiliation>Central Research Department, E. I. du Pont de Nemours and Company, P. O. Box 80228, 19880-0228, Wilmington, DE.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Delaware</region>
</placeName>
<wicri:cityArea>Central Research Department, E. I. du Pont de Nemours and Company, P. O. Box 80228, 19880-0228, Wilmington</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Simonsick, W J" sort="Simonsick, W J" uniqKey="Simonsick W" first="W J" last="Simonsick">W J Simonsick</name>
</author>
<author><name sortKey="Larsen, B S" sort="Larsen, B S" uniqKey="Larsen B" first="B S" last="Larsen">B S Larsen</name>
</author>
<author><name sortKey="Ute, K" sort="Ute, K" uniqKey="Ute K" first="K" last="Ute">K. Ute</name>
</author>
<author><name sortKey="Hatada, K" sort="Hatada, K" uniqKey="Hatada K" first="K" last="Hatada">K. Hatada</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:24214034</idno>
<idno type="pmid">24214034</idno>
<idno type="doi">10.1016/1044-0305(95)00476-T</idno>
<idno type="wicri:Area/PubMed/Corpus">002799</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002799</idno>
<idno type="wicri:Area/PubMed/Curation">002799</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002799</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002650</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002650</idno>
<idno type="wicri:Area/Ncbi/Merge">000B95</idno>
<idno type="wicri:Area/Ncbi/Curation">000B95</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000B95</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers.</title>
<author><name sortKey="Mcewen, C N" sort="Mcewen, C N" uniqKey="Mcewen C" first="C N" last="Mcewen">C N Mcewen</name>
<affiliation wicri:level="2"><nlm:affiliation>Central Research Department, E. I. du Pont de Nemours and Company, P. O. Box 80228, 19880-0228, Wilmington, DE.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<placeName><region type="state">Delaware</region>
</placeName>
<wicri:cityArea>Central Research Department, E. I. du Pont de Nemours and Company, P. O. Box 80228, 19880-0228, Wilmington</wicri:cityArea>
</affiliation>
</author>
<author><name sortKey="Simonsick, W J" sort="Simonsick, W J" uniqKey="Simonsick W" first="W J" last="Simonsick">W J Simonsick</name>
</author>
<author><name sortKey="Larsen, B S" sort="Larsen, B S" uniqKey="Larsen B" first="B S" last="Larsen">B S Larsen</name>
</author>
<author><name sortKey="Ute, K" sort="Ute, K" uniqKey="Ute K" first="K" last="Ute">K. Ute</name>
</author>
<author><name sortKey="Hatada, K" sort="Hatada, K" uniqKey="Hatada K" first="K" last="Hatada">K. Hatada</name>
</author>
</analytic>
<series><title level="j">Journal of the American Society for Mass Spectrometry</title>
<idno type="ISSN">1044-0305</idno>
<imprint><date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Electrospray ionization (ESI) is capable of ionizing many soluble polymers. The ESI spectra are complex because of overlap of the multiply charged ions of the oligomer distribution, causing current computer transform programs to fail. However, it is possible to determine the origin of the multiply charged ions, making it feasible to write a program designed to transform ESI polymer spectra. To assess the value of such a program for polymer analysis, isolated monodisperse methyl methacrylate (MMA) oligomers (25 and 50 repeat units) were used to determine molar signal response and propensity for fragmentation.The sum of the peak areas for the multiply charged MMA 50-mer was found to be only about 66% of the summed peak areas for the 25-mer for the same molar concentration. However, conversion of the multiply charged peak areas to the singly charged representations, with peak area compression taken into account, gave equal signal responses for the 25-and 50-mers. Signal response variations due to the tacticity of the MMA oligomers were not observed. Fragmentation of the MMA oligomers also was shown not to occur under normal ESI conditions. Therefore, transformation of the polymer spectra to the singly charged molecular ion distribution should allow accurate calculation of average molecular weights, polydispersity, end group mass, and repeat unit mass. </div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Delaware</li>
</region>
</list>
<tree><noCountry><name sortKey="Hatada, K" sort="Hatada, K" uniqKey="Hatada K" first="K" last="Hatada">K. Hatada</name>
<name sortKey="Larsen, B S" sort="Larsen, B S" uniqKey="Larsen B" first="B S" last="Larsen">B S Larsen</name>
<name sortKey="Simonsick, W J" sort="Simonsick, W J" uniqKey="Simonsick W" first="W J" last="Simonsick">W J Simonsick</name>
<name sortKey="Ute, K" sort="Ute, K" uniqKey="Ute K" first="K" last="Ute">K. Ute</name>
</noCountry>
<country name="États-Unis"><region name="Delaware"><name sortKey="Mcewen, C N" sort="Mcewen, C N" uniqKey="Mcewen C" first="C N" last="Mcewen">C N Mcewen</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Sante/explor/MersV1/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B95 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 000B95 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Sante |area= MersV1 |flux= Ncbi |étape= Checkpoint |type= RBID |clé= pubmed:24214034 |texte= The fundamentals of applying electrospray ionization mass spectrometry to low mass poly(methyl methacrylate) polymers. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i -Sk "pubmed:24214034" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd \ | NlmPubMed2Wicri -a MersV1
This area was generated with Dilib version V0.6.33. |