Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.
Identifieur interne : 000761 ( Main/Curation ); précédent : 000760; suivant : 000762Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.
Auteurs : Hua Qian [République populaire de Chine] ; Xiaohong Zheng [République populaire de Chine]Source :
- Journal of thoracic disease [ 2072-1439 ] ; 2018.
Abstract
The emergence of respiratory diseases, i.e., severe acute respiratory syndrome (SARS) epidemic in 2003, H1N1 influenza epidemic in 2011 and Middle East respiratory syndrome (MERS) outbreak, reiterated the significance of ventilation in buildings. The role of ventilation in removing exhaled airborne bio-aerosols and preventing cross infections has been multidisciplinary extensively studied after the SARS outbreak in 2003. The characteristics of droplet-borne, short-range airborne and long-range airborne transmission of infectious diseases were identified. Increasing ventilation rate can effectively reduce the risk of long-range airborne transmission, while it may be of little useful in preventing the droplet-borne transmission. To maintain the airflow direction from clean cubicles to dirty cubicles is an effective way to prevent the cross infection between cubicles, which is widely used in hospital isolation rooms. Field measurements showed that wrong air flow direction was due to poor construction quality or maintenance. The impacts of different airflow patterns on removing large droplets and fine droplet nuclei were discussed. Some new concepts in general ventilation systems and local personalized equipment were also introduced. This review updates current knowledge of the airborne transmission of pathogens and the improvement of ventilation efficiency concerning the infection prevention.
DOI: 10.21037/jtd.2018.01.24
PubMed: 30116608
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :000808
- to stream PubMed, to step Curation: Pour aller vers cette notice dans l'étape Curation :000808
- to stream PubMed, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :000722
- to stream Ncbi, to step Merge: Pour aller vers cette notice dans l'étape Curation :001F34
- to stream Ncbi, to step Curation: Pour aller vers cette notice dans l'étape Curation :001F34
- to stream Ncbi, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :001F34
- to stream Main, to step Merge: Pour aller vers cette notice dans l'étape Curation :000764
Links to Exploration step
pubmed:30116608Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.</title>
<author><name sortKey="Qian, Hua" sort="Qian, Hua" uniqKey="Qian H" first="Hua" last="Qian">Hua Qian</name>
<affiliation wicri:level="1"><nlm:affiliation>School of Energy and Environment, Southeast University, Nanjing 210096, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>School of Energy and Environment, Southeast University, Nanjing 210096</wicri:regionArea>
<wicri:noRegion>Nanjing 210096</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Zheng, Xiaohong" sort="Zheng, Xiaohong" uniqKey="Zheng X" first="Xiaohong" last="Zheng">Xiaohong Zheng</name>
<affiliation wicri:level="1"><nlm:affiliation>School of Energy and Environment, Southeast University, Nanjing 210096, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>School of Energy and Environment, Southeast University, Nanjing 210096</wicri:regionArea>
<wicri:noRegion>Nanjing 210096</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2018">2018</date>
<idno type="RBID">pubmed:30116608</idno>
<idno type="pmid">30116608</idno>
<idno type="doi">10.21037/jtd.2018.01.24</idno>
<idno type="wicri:Area/PubMed/Corpus">000808</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000808</idno>
<idno type="wicri:Area/PubMed/Curation">000808</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000808</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000722</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000722</idno>
<idno type="wicri:Area/Ncbi/Merge">001F34</idno>
<idno type="wicri:Area/Ncbi/Curation">001F34</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001F34</idno>
<idno type="wicri:doubleKey">2072-1439:2018:Qian H:ventilation:control:for</idno>
<idno type="wicri:Area/Main/Merge">000764</idno>
<idno type="wicri:Area/Main/Curation">000761</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.</title>
<author><name sortKey="Qian, Hua" sort="Qian, Hua" uniqKey="Qian H" first="Hua" last="Qian">Hua Qian</name>
<affiliation wicri:level="1"><nlm:affiliation>School of Energy and Environment, Southeast University, Nanjing 210096, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>School of Energy and Environment, Southeast University, Nanjing 210096</wicri:regionArea>
<wicri:noRegion>Nanjing 210096</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Zheng, Xiaohong" sort="Zheng, Xiaohong" uniqKey="Zheng X" first="Xiaohong" last="Zheng">Xiaohong Zheng</name>
<affiliation wicri:level="1"><nlm:affiliation>School of Energy and Environment, Southeast University, Nanjing 210096, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>School of Energy and Environment, Southeast University, Nanjing 210096</wicri:regionArea>
<wicri:noRegion>Nanjing 210096</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of thoracic disease</title>
<idno type="ISSN">2072-1439</idno>
<imprint><date when="2018" type="published">2018</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The emergence of respiratory diseases, i.e., severe acute respiratory syndrome (SARS) epidemic in 2003, H1N1 influenza epidemic in 2011 and Middle East respiratory syndrome (MERS) outbreak, reiterated the significance of ventilation in buildings. The role of ventilation in removing exhaled airborne bio-aerosols and preventing cross infections has been multidisciplinary extensively studied after the SARS outbreak in 2003. The characteristics of droplet-borne, short-range airborne and long-range airborne transmission of infectious diseases were identified. Increasing ventilation rate can effectively reduce the risk of long-range airborne transmission, while it may be of little useful in preventing the droplet-borne transmission. To maintain the airflow direction from clean cubicles to dirty cubicles is an effective way to prevent the cross infection between cubicles, which is widely used in hospital isolation rooms. Field measurements showed that wrong air flow direction was due to poor construction quality or maintenance. The impacts of different airflow patterns on removing large droplets and fine droplet nuclei were discussed. Some new concepts in general ventilation systems and local personalized equipment were also introduced. This review updates current knowledge of the airborne transmission of pathogens and the improvement of ventilation efficiency concerning the infection prevention.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Sante/explor/MersV1/Data/Main/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000761 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Curation/biblio.hfd -nk 000761 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Sante |area= MersV1 |flux= Main |étape= Curation |type= RBID |clé= pubmed:30116608 |texte= Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Curation/RBID.i -Sk "pubmed:30116608" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Curation/biblio.hfd \ | NlmPubMed2Wicri -a MersV1
This area was generated with Dilib version V0.6.33. |