Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.

Identifieur interne : 000958 ( PubMed/Curation ); précédent : 000957; suivant : 000959

Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.

Auteurs : Nicola Cau [Italie] ; Manuela Galli [Italie] ; Veronica Cimolin [Italie] ; Marta Aranci [Italie] ; Augusto Caraceni [Italie] ; Augusta Balzarini [Italie]

Source :

RBID : pubmed:26946898

Abstract

Accurate and convenient measurement of upper limb volume is an important clinical tool to measure incidence of lymphedema and response to treatments. There are several methods used to evaluate arm volumes. The most commonly used methods include water displacement and circumferential method (CM), but these techniques have some limitation in use and accuracy that needs the use of a new technique for volume and swelling detection: laser scanner 3D method (LS3D). The aim of the study was to compare, in terms of intra- and interreliability, the CM and LS3D methods for the upper limb measure in a healthy subject group.

DOI: 10.1016/j.jvsv.2015.05.005
PubMed: 26946898

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:26946898

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.</title>
<author>
<name sortKey="Cau, Nicola" sort="Cau, Nicola" uniqKey="Cau N" first="Nicola" last="Cau">Nicola Cau</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address: nicola.cau@gmail.com.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Galli, Manuela" sort="Galli, Manuela" uniqKey="Galli M" first="Manuela" last="Galli">Manuela Galli</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; IRCCS "San Raffaele Pisana", Tosinvest Sanità, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; IRCCS "San Raffaele Pisana", Tosinvest Sanità, Rome</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Cimolin, Veronica" sort="Cimolin, Veronica" uniqKey="Cimolin V" first="Veronica" last="Cimolin">Veronica Cimolin</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Aranci, Marta" sort="Aranci, Marta" uniqKey="Aranci M" first="Marta" last="Aranci">Marta Aranci</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Caraceni, Augusto" sort="Caraceni, Augusto" uniqKey="Caraceni A" first="Augusto" last="Caraceni">Augusto Caraceni</name>
<affiliation wicri:level="1">
<nlm:affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Balzarini, Augusta" sort="Balzarini, Augusta" uniqKey="Balzarini A" first="Augusta" last="Balzarini">Augusta Balzarini</name>
<affiliation wicri:level="1">
<nlm:affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2016">2016</date>
<idno type="RBID">pubmed:26946898</idno>
<idno type="pmid">26946898</idno>
<idno type="doi">10.1016/j.jvsv.2015.05.005</idno>
<idno type="wicri:Area/PubMed/Corpus">000958</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000958</idno>
<idno type="wicri:Area/PubMed/Curation">000958</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000958</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.</title>
<author>
<name sortKey="Cau, Nicola" sort="Cau, Nicola" uniqKey="Cau N" first="Nicola" last="Cau">Nicola Cau</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address: nicola.cau@gmail.com.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Galli, Manuela" sort="Galli, Manuela" uniqKey="Galli M" first="Manuela" last="Galli">Manuela Galli</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; IRCCS "San Raffaele Pisana", Tosinvest Sanità, Rome, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; IRCCS "San Raffaele Pisana", Tosinvest Sanità, Rome</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Cimolin, Veronica" sort="Cimolin, Veronica" uniqKey="Cimolin V" first="Veronica" last="Cimolin">Veronica Cimolin</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Aranci, Marta" sort="Aranci, Marta" uniqKey="Aranci M" first="Marta" last="Aranci">Marta Aranci</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Caraceni, Augusto" sort="Caraceni, Augusto" uniqKey="Caraceni A" first="Augusto" last="Caraceni">Augusto Caraceni</name>
<affiliation wicri:level="1">
<nlm:affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Balzarini, Augusta" sort="Balzarini, Augusta" uniqKey="Balzarini A" first="Augusta" last="Balzarini">Augusta Balzarini</name>
<affiliation wicri:level="1">
<nlm:affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</nlm:affiliation>
<country xml:lang="fr">Italie</country>
<wicri:regionArea>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of vascular surgery. Venous and lymphatic disorders</title>
<idno type="eISSN">2213-3348</idno>
<imprint>
<date when="2016" type="published">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Accurate and convenient measurement of upper limb volume is an important clinical tool to measure incidence of lymphedema and response to treatments. There are several methods used to evaluate arm volumes. The most commonly used methods include water displacement and circumferential method (CM), but these techniques have some limitation in use and accuracy that needs the use of a new technique for volume and swelling detection: laser scanner 3D method (LS3D). The aim of the study was to compare, in terms of intra- and interreliability, the CM and LS3D methods for the upper limb measure in a healthy subject group.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="In-Process" Owner="NLM">
<PMID Version="1">26946898</PMID>
<DateCreated>
<Year>2016</Year>
<Month>03</Month>
<Day>07</Day>
</DateCreated>
<DateRevised>
<Year>2016</Year>
<Month>03</Month>
<Day>07</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">2213-3348</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>4</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2016</Year>
<Month>Jan</Month>
</PubDate>
</JournalIssue>
<Title>Journal of vascular surgery. Venous and lymphatic disorders</Title>
<ISOAbbreviation>J Vasc Surg Venous Lymphat Disord</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.</ArticleTitle>
<Pagination>
<MedlinePgn>64-72</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jvsv.2015.05.005</ELocationID>
<ELocationID EIdType="pii" ValidYN="Y">S2213-333X(15)00105-5</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">Accurate and convenient measurement of upper limb volume is an important clinical tool to measure incidence of lymphedema and response to treatments. There are several methods used to evaluate arm volumes. The most commonly used methods include water displacement and circumferential method (CM), but these techniques have some limitation in use and accuracy that needs the use of a new technique for volume and swelling detection: laser scanner 3D method (LS3D). The aim of the study was to compare, in terms of intra- and interreliability, the CM and LS3D methods for the upper limb measure in a healthy subject group.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Twelve healthy adults (average age, 29 ± 5.39 years; average weight, 63.88 ± 7.97 kg; and average height, 168.38 ± 7.29 cm) participated. Arm measurements were done using both CM and LS3D methods. Statistical analysis was conducted, and intra- and inter-reliability was investigated. CM and LS3D methods were also compared in terms of level of agreement.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Both CM and LS3D methods have a high inter- and intrarater reliability and a satisfactory level of agreement, but we found a statistically significant difference in terms of volume. The laser scanner is a more accurate volume instrument, and our results shown a statistically significant difference of volumes between methods.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Our findings provide LS3D is an innovative method of measuring the upper limb volume that could be used instead of CM. It combines precision, reproducibility, ease of use, and the ability to measure geometrical parameters and shape information of the scanned limb.</AbstractText>
<CopyrightInformation>Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Cau</LastName>
<ForeName>Nicola</ForeName>
<Initials>N</Initials>
<AffiliationInfo>
<Affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address: nicola.cau@gmail.com.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Galli</LastName>
<ForeName>Manuela</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; IRCCS "San Raffaele Pisana", Tosinvest Sanità, Rome, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Cimolin</LastName>
<ForeName>Veronica</ForeName>
<Initials>V</Initials>
<AffiliationInfo>
<Affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Aranci</LastName>
<ForeName>Marta</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Caraceni</LastName>
<ForeName>Augusto</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Balzarini</LastName>
<ForeName>Augusta</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Palliative Care (Pain Therapy - Rehabilitation) Fondazione IRCCS, National Cancer Institute of Milan, Milan, Italy.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2015</Year>
<Month>07</Month>
<Day>14</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Vasc Surg Venous Lymphat Disord</MedlineTA>
<NlmUniqueID>101607771</NlmUniqueID>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2015</Year>
<Month>02</Month>
<Day>26</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2015</Year>
<Month>05</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2016</Year>
<Month>3</Month>
<Day>8</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2016</Year>
<Month>3</Month>
<Day>8</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2016</Year>
<Month>3</Month>
<Day>8</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">26946898</ArticleId>
<ArticleId IdType="pii">S2213-333X(15)00105-5</ArticleId>
<ArticleId IdType="doi">10.1016/j.jvsv.2015.05.005</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000958 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000958 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:26946898
   |texte=   Comparative study between circumferential method and laser scanner 3D method for the evaluation of arm volume in healthy subjects.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:26946898" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024