Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.

Identifieur interne : 002072 ( PubMed/Corpus ); précédent : 002071; suivant : 002073

Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.

Auteurs : H Kan Brorson ; Emma Hansson ; Erik Jense ; Carolin Freccero

Source :

RBID : pubmed:22720662

English descriptors

Abstract

The use of compression garments in treating lymphedema following treatment of genital (penis, testes, uterus, cervical) and breast cancer treatment is a well-established practice. Although compression garments are classified in compression classes, little is known about the actual subgarment pressure exerted along the extremity. The aims of this study were to establish an in vitro method for measuring subgarment pressure along the extremity and to analyze initial and over time subgarment pressure of compression garments from three manufacturers. The measurements were performed with I-scan(®) (Tekscan Inc.) pressure measuring equipment once a week during a period of 4 weeks. Wear and tear was simulated by washing and putting on the garments on plastic legs every day. There was a statistically significant difference between the garments of some of manufacturers. There was no difference between garments from the same manufacturer. No significant decrease of subgarment pressure was observed during the trial period. The study demonstrated that Tekscan pressure-measuring equipment could measure subgarment pressure in vitro. The results may indicate that there was a difference in subgarment pressure exerted by garments from different manufacturers and that there was no clear decrease in subgarment pressure during the first four weeks of usage.

DOI: 10.1089/lrb.2012.0003
PubMed: 22720662

Links to Exploration step

pubmed:22720662

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.</title>
<author>
<name sortKey="Brorson, H Kan" sort="Brorson, H Kan" uniqKey="Brorson H" first="H Kan" last="Brorson">H Kan Brorson</name>
<affiliation>
<nlm:affiliation>Department of Clinical Sciences, Lund University, Plastic and Reconstructive Surgery, Skåne University Hospital, Malmö, Sweden. hakan.brorson@med.lu.se</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Hansson, Emma" sort="Hansson, Emma" uniqKey="Hansson E" first="Emma" last="Hansson">Emma Hansson</name>
</author>
<author>
<name sortKey="Jense, Erik" sort="Jense, Erik" uniqKey="Jense E" first="Erik" last="Jense">Erik Jense</name>
</author>
<author>
<name sortKey="Freccero, Carolin" sort="Freccero, Carolin" uniqKey="Freccero C" first="Carolin" last="Freccero">Carolin Freccero</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22720662</idno>
<idno type="pmid">22720662</idno>
<idno type="doi">10.1089/lrb.2012.0003</idno>
<idno type="wicri:Area/PubMed/Corpus">002072</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002072</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.</title>
<author>
<name sortKey="Brorson, H Kan" sort="Brorson, H Kan" uniqKey="Brorson H" first="H Kan" last="Brorson">H Kan Brorson</name>
<affiliation>
<nlm:affiliation>Department of Clinical Sciences, Lund University, Plastic and Reconstructive Surgery, Skåne University Hospital, Malmö, Sweden. hakan.brorson@med.lu.se</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Hansson, Emma" sort="Hansson, Emma" uniqKey="Hansson E" first="Emma" last="Hansson">Emma Hansson</name>
</author>
<author>
<name sortKey="Jense, Erik" sort="Jense, Erik" uniqKey="Jense E" first="Erik" last="Jense">Erik Jense</name>
</author>
<author>
<name sortKey="Freccero, Carolin" sort="Freccero, Carolin" uniqKey="Freccero C" first="Carolin" last="Freccero">Carolin Freccero</name>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Compression Bandages (classification)</term>
<term>Compression Bandages (standards)</term>
<term>Equipment Design</term>
<term>Humans</term>
<term>Lymphedema (therapy)</term>
<term>Materials Testing (instrumentation)</term>
<term>Materials Testing (methods)</term>
<term>Pressure</term>
<term>Reproducibility of Results</term>
<term>Textiles (classification)</term>
<term>Textiles (standards)</term>
<term>Time Factors</term>
</keywords>
<keywords scheme="MESH" qualifier="classification" xml:lang="en">
<term>Compression Bandages</term>
<term>Textiles</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Materials Testing</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Materials Testing</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Compression Bandages</term>
<term>Textiles</term>
</keywords>
<keywords scheme="MESH" qualifier="therapy" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Equipment Design</term>
<term>Humans</term>
<term>Pressure</term>
<term>Reproducibility of Results</term>
<term>Time Factors</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The use of compression garments in treating lymphedema following treatment of genital (penis, testes, uterus, cervical) and breast cancer treatment is a well-established practice. Although compression garments are classified in compression classes, little is known about the actual subgarment pressure exerted along the extremity. The aims of this study were to establish an in vitro method for measuring subgarment pressure along the extremity and to analyze initial and over time subgarment pressure of compression garments from three manufacturers. The measurements were performed with I-scan(®) (Tekscan Inc.) pressure measuring equipment once a week during a period of 4 weeks. Wear and tear was simulated by washing and putting on the garments on plastic legs every day. There was a statistically significant difference between the garments of some of manufacturers. There was no difference between garments from the same manufacturer. No significant decrease of subgarment pressure was observed during the trial period. The study demonstrated that Tekscan pressure-measuring equipment could measure subgarment pressure in vitro. The results may indicate that there was a difference in subgarment pressure exerted by garments from different manufacturers and that there was no clear decrease in subgarment pressure during the first four weeks of usage.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">22720662</PMID>
<DateCreated>
<Year>2012</Year>
<Month>06</Month>
<Day>22</Day>
</DateCreated>
<DateCompleted>
<Year>2012</Year>
<Month>10</Month>
<Day>19</Day>
</DateCompleted>
<DateRevised>
<Year>2012</Year>
<Month>06</Month>
<Day>22</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1557-8585</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>10</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2012</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Lymphatic research and biology</Title>
<ISOAbbreviation>Lymphat Res Biol</ISOAbbreviation>
</Journal>
<ArticleTitle>Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.</ArticleTitle>
<Pagination>
<MedlinePgn>74-80</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1089/lrb.2012.0003</ELocationID>
<Abstract>
<AbstractText>The use of compression garments in treating lymphedema following treatment of genital (penis, testes, uterus, cervical) and breast cancer treatment is a well-established practice. Although compression garments are classified in compression classes, little is known about the actual subgarment pressure exerted along the extremity. The aims of this study were to establish an in vitro method for measuring subgarment pressure along the extremity and to analyze initial and over time subgarment pressure of compression garments from three manufacturers. The measurements were performed with I-scan(®) (Tekscan Inc.) pressure measuring equipment once a week during a period of 4 weeks. Wear and tear was simulated by washing and putting on the garments on plastic legs every day. There was a statistically significant difference between the garments of some of manufacturers. There was no difference between garments from the same manufacturer. No significant decrease of subgarment pressure was observed during the trial period. The study demonstrated that Tekscan pressure-measuring equipment could measure subgarment pressure in vitro. The results may indicate that there was a difference in subgarment pressure exerted by garments from different manufacturers and that there was no clear decrease in subgarment pressure during the first four weeks of usage.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Brorson</LastName>
<ForeName>Håkan</ForeName>
<Initials>H</Initials>
<AffiliationInfo>
<Affiliation>Department of Clinical Sciences, Lund University, Plastic and Reconstructive Surgery, Skåne University Hospital, Malmö, Sweden. hakan.brorson@med.lu.se</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Hansson</LastName>
<ForeName>Emma</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Jense</LastName>
<ForeName>Erik</ForeName>
<Initials>E</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Freccero</LastName>
<ForeName>Carolin</ForeName>
<Initials>C</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Lymphat Res Biol</MedlineTA>
<NlmUniqueID>101163587</NlmUniqueID>
<ISSNLinking>1539-6851</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D058128" MajorTopicYN="N">Compression Bandages</DescriptorName>
<QualifierName UI="Q000145" MajorTopicYN="N">classification</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004867" MajorTopicYN="N">Equipment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008209" MajorTopicYN="N">Lymphedema</DescriptorName>
<QualifierName UI="Q000628" MajorTopicYN="Y">therapy</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008422" MajorTopicYN="N">Materials Testing</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011312" MajorTopicYN="N">Pressure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013784" MajorTopicYN="N">Textiles</DescriptorName>
<QualifierName UI="Q000145" MajorTopicYN="N">classification</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013997" MajorTopicYN="N">Time Factors</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>6</Month>
<Day>23</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>6</Month>
<Day>23</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>10</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">22720662</ArticleId>
<ArticleId IdType="doi">10.1089/lrb.2012.0003</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002072 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002072 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:22720662
   |texte=   Development of a pressure-measuring device to optimize compression treatment of lymphedema and evaluation of change in garment pressure with simulated wear and tear.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:22720662" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024