Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A new soft tissue volume measurement strategy using ultrasonography.

Identifieur interne : 001677 ( PubMed/Corpus ); précédent : 001676; suivant : 001678

A new soft tissue volume measurement strategy using ultrasonography.

Auteurs : Ji Hye Hwang ; Chang-Hyung Lee ; Hae Hyun Lee ; Soo Yeon Kim

Source :

RBID : pubmed:24521479

English descriptors

Abstract

Abstract Various techniques are available for measuring the status of lymphedema. A modified imaging technique using ultrasonography was developed to measure the structure of soft tissue area in a cost-effective manner. The purpose of this study was to measure the reliability and the accuracy of this new method. Ultrasonography was performed on both arms of twenty healthy female participants. At 10 cm above (AE) and below (BE) the elbow crease, soft tissue thickness at medial, lateral, inferior, and superior locations were measured by two examiners with minimal unnecessary pressure. After measuring twice on 16 sites for each participant, the amount of soft tissue in the cross-sectional area (ΔCSA) was acquired by a designed formulation. The ΔCSA was also compared with volumetry data (Perometer(®)). Cronbach's alpha coefficient test was used for statistics. The intra-class and inter-class reliability measurements for all soft tissue areas were very strong (α=0.980 and 0.960, respectively; p<0.01). All AE and BE reliabilities showed very strong correlation and strong correlation of inter-BE measurement. All reliabilities of ΔCSA were very strong (≥0.950). All CCs (correlation coefficients) between ΔCSA, circumference, and volumetry were strong for AE and BE measurements, except for ΔCSA and circumference at BE. The strongest CC was between volumetry and circumference measurements. This study suggests that measuring the ΔCSA by ultrasonography could be an alternative way to measure the status of soft tissue indirectly with structural consideration.

DOI: 10.1089/lrb.2013.0030
PubMed: 24521479

Links to Exploration step

pubmed:24521479

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A new soft tissue volume measurement strategy using ultrasonography.</title>
<author>
<name sortKey="Hwang, Ji Hye" sort="Hwang, Ji Hye" uniqKey="Hwang J" first="Ji Hye" last="Hwang">Ji Hye Hwang</name>
<affiliation>
<nlm:affiliation>1 Department of Physical Medicine and Rehabilitation, Samsung Medical Center, Center for Clinical Research, Sungkyunkwan University School of Medicine , Seoul, Republic of Korea.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lee, Chang Hyung" sort="Lee, Chang Hyung" uniqKey="Lee C" first="Chang-Hyung" last="Lee">Chang-Hyung Lee</name>
</author>
<author>
<name sortKey="Lee, Hae Hyun" sort="Lee, Hae Hyun" uniqKey="Lee H" first="Hae Hyun" last="Lee">Hae Hyun Lee</name>
</author>
<author>
<name sortKey="Kim, Soo Yeon" sort="Kim, Soo Yeon" uniqKey="Kim S" first="Soo Yeon" last="Kim">Soo Yeon Kim</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:24521479</idno>
<idno type="pmid">24521479</idno>
<idno type="doi">10.1089/lrb.2013.0030</idno>
<idno type="wicri:Area/PubMed/Corpus">001677</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001677</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A new soft tissue volume measurement strategy using ultrasonography.</title>
<author>
<name sortKey="Hwang, Ji Hye" sort="Hwang, Ji Hye" uniqKey="Hwang J" first="Ji Hye" last="Hwang">Ji Hye Hwang</name>
<affiliation>
<nlm:affiliation>1 Department of Physical Medicine and Rehabilitation, Samsung Medical Center, Center for Clinical Research, Sungkyunkwan University School of Medicine , Seoul, Republic of Korea.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lee, Chang Hyung" sort="Lee, Chang Hyung" uniqKey="Lee C" first="Chang-Hyung" last="Lee">Chang-Hyung Lee</name>
</author>
<author>
<name sortKey="Lee, Hae Hyun" sort="Lee, Hae Hyun" uniqKey="Lee H" first="Hae Hyun" last="Lee">Hae Hyun Lee</name>
</author>
<author>
<name sortKey="Kim, Soo Yeon" sort="Kim, Soo Yeon" uniqKey="Kim S" first="Soo Yeon" last="Kim">Soo Yeon Kim</name>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Anthropometry (instrumentation)</term>
<term>Anthropometry (methods)</term>
<term>Arm (diagnostic imaging)</term>
<term>Female</term>
<term>Humans</term>
<term>Linear Models</term>
<term>Pressure</term>
<term>Reproducibility of Results</term>
<term>Ultrasonography</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Arm</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Anthropometry</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Anthropometry</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Linear Models</term>
<term>Pressure</term>
<term>Reproducibility of Results</term>
<term>Ultrasonography</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract Various techniques are available for measuring the status of lymphedema. A modified imaging technique using ultrasonography was developed to measure the structure of soft tissue area in a cost-effective manner. The purpose of this study was to measure the reliability and the accuracy of this new method. Ultrasonography was performed on both arms of twenty healthy female participants. At 10 cm above (AE) and below (BE) the elbow crease, soft tissue thickness at medial, lateral, inferior, and superior locations were measured by two examiners with minimal unnecessary pressure. After measuring twice on 16 sites for each participant, the amount of soft tissue in the cross-sectional area (ΔCSA) was acquired by a designed formulation. The ΔCSA was also compared with volumetry data (Perometer(®)). Cronbach's alpha coefficient test was used for statistics. The intra-class and inter-class reliability measurements for all soft tissue areas were very strong (α=0.980 and 0.960, respectively; p<0.01). All AE and BE reliabilities showed very strong correlation and strong correlation of inter-BE measurement. All reliabilities of ΔCSA were very strong (≥0.950). All CCs (correlation coefficients) between ΔCSA, circumference, and volumetry were strong for AE and BE measurements, except for ΔCSA and circumference at BE. The strongest CC was between volumetry and circumference measurements. This study suggests that measuring the ΔCSA by ultrasonography could be an alternative way to measure the status of soft tissue indirectly with structural consideration.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">24521479</PMID>
<DateCreated>
<Year>2014</Year>
<Month>06</Month>
<Day>14</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>01</Month>
<Day>26</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1557-8585</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>12</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2014</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Lymphatic research and biology</Title>
<ISOAbbreviation>Lymphat Res Biol</ISOAbbreviation>
</Journal>
<ArticleTitle>A new soft tissue volume measurement strategy using ultrasonography.</ArticleTitle>
<Pagination>
<MedlinePgn>89-94</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1089/lrb.2013.0030</ELocationID>
<Abstract>
<AbstractText>Abstract Various techniques are available for measuring the status of lymphedema. A modified imaging technique using ultrasonography was developed to measure the structure of soft tissue area in a cost-effective manner. The purpose of this study was to measure the reliability and the accuracy of this new method. Ultrasonography was performed on both arms of twenty healthy female participants. At 10 cm above (AE) and below (BE) the elbow crease, soft tissue thickness at medial, lateral, inferior, and superior locations were measured by two examiners with minimal unnecessary pressure. After measuring twice on 16 sites for each participant, the amount of soft tissue in the cross-sectional area (ΔCSA) was acquired by a designed formulation. The ΔCSA was also compared with volumetry data (Perometer(®)). Cronbach's alpha coefficient test was used for statistics. The intra-class and inter-class reliability measurements for all soft tissue areas were very strong (α=0.980 and 0.960, respectively; p<0.01). All AE and BE reliabilities showed very strong correlation and strong correlation of inter-BE measurement. All reliabilities of ΔCSA were very strong (≥0.950). All CCs (correlation coefficients) between ΔCSA, circumference, and volumetry were strong for AE and BE measurements, except for ΔCSA and circumference at BE. The strongest CC was between volumetry and circumference measurements. This study suggests that measuring the ΔCSA by ultrasonography could be an alternative way to measure the status of soft tissue indirectly with structural consideration.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Hwang</LastName>
<ForeName>Ji Hye</ForeName>
<Initials>JH</Initials>
<AffiliationInfo>
<Affiliation>1 Department of Physical Medicine and Rehabilitation, Samsung Medical Center, Center for Clinical Research, Sungkyunkwan University School of Medicine , Seoul, Republic of Korea.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Lee</LastName>
<ForeName>Chang-Hyung</ForeName>
<Initials>CH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lee</LastName>
<ForeName>Hae Hyun</ForeName>
<Initials>HH</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Kim</LastName>
<ForeName>Soo Yeon</ForeName>
<Initials>SY</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2014</Year>
<Month>02</Month>
<Day>12</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Lymphat Res Biol</MedlineTA>
<NlmUniqueID>101163587</NlmUniqueID>
<ISSNLinking>1539-6851</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<CommentsCorrectionsList>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2000 Sep;33(3):122-35</RefSource>
<PMID Version="1">11019400</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Chir Narzadow Ruchu Ortop Pol. 2000;65(3):315-25</RefSource>
<PMID Version="1">11057020</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Arch Phys Med Rehabil. 2001 Dec;82(12):1639-44</RefSource>
<PMID Version="1">11733875</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2001 Dec;34(4):152-5</RefSource>
<PMID Version="1">11783592</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Orv Hetil. 2004 May 30;145(22):1177-81</RefSource>
<PMID Version="1">15279405</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Radiol Technol. 1998 Sep-Oct;70(1):42-56; quiz 57-60</RefSource>
<PMID Version="1">9779509</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Breast J. 2004 Nov-Dec;10(6):496-503</RefSource>
<PMID Version="1">15569205</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Br J Surg. 2005 Mar;92(3):311-5</RefSource>
<PMID Version="1">15672436</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Nucl Med Rev Cent East Eur. 2005;8(1):37-43</RefSource>
<PMID Version="1">15977145</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>MMW Fortschr Med. 2005 Dec 15;147(51-52):38-40; quiz 49-50</RefSource>
<PMID Version="1">16402708</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2006 Sep;39(3):118-26</RefSource>
<PMID Version="1">17036632</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2007 Mar;40(1):26-34</RefSource>
<PMID Version="1">17539462</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Sport Exerc Psychol. 2008 Feb;30(1):23-38</RefSource>
<PMID Version="1">18369241</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Breast Cancer Res Treat. 2008 May;109(1):9-26</RefSource>
<PMID Version="1">17624588</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Breast Cancer Res Treat. 2008 May;109(2):285-95</RefSource>
<PMID Version="1">17624606</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Cancer Nurs. 2008 Mar-Apr;31(2):160-5</RefSource>
<PMID Version="1">18490892</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Surg Oncol. 2008 Jun 1;97(7):572-7</RefSource>
<PMID Version="1">18459131</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2008 Mar;41(1):40-4</RefSource>
<PMID Version="1">18581957</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Br J Community Nurs. 2008 Apr;13(4):S4, S6, S8-10</RefSource>
<PMID Version="1">18595306</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Wiad Lek. 2008;61(1-3):4-12</RefSource>
<PMID Version="1">18717036</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Eur J Cancer Care (Engl). 2008 Nov;17(6):557-64</RefSource>
<PMID Version="1">18771539</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Br J Community Nurs. 2008 Oct;13(10):S4-9</RefSource>
<PMID Version="1">19057484</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Br J Community Nurs. 2008 Dec;13(12):S24, S26, S28 passim</RefSource>
<PMID Version="1">19060825</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphology. 2008 Dec;41(4):167-77</RefSource>
<PMID Version="1">19306663</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>J Vasc Surg. 2009 Apr;49(4):980-7</RefSource>
<PMID Version="1">19223143</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Br J Dermatol. 2010 Aug;163(2):296-301</RefSource>
<PMID Version="1">20408836</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphat Res Biol. 2011;9(3):135-41</RefSource>
<PMID Version="1">22066743</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphat Res Biol. 2012 Jun;10(2):81-6</RefSource>
<PMID Version="1">22720663</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Lymphat Res Biol. 2013 Jun;11(2):104-9</RefSource>
<PMID Version="1">23772720</PMID>
</CommentsCorrections>
<CommentsCorrections RefType="Cites">
<RefSource>Skin Res Technol. 2014 Aug;20(3):274-81</RefSource>
<PMID Version="1">24283509</PMID>
</CommentsCorrections>
</CommentsCorrectionsList>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000886" MajorTopicYN="N">Anthropometry</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001132" MajorTopicYN="N">Arm</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016014" MajorTopicYN="N">Linear Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011312" MajorTopicYN="N">Pressure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014463" MajorTopicYN="N">Ultrasonography</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<OtherID Source="NLM">PMC4062108</OtherID>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>2</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>2</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>1</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">24521479</ArticleId>
<ArticleId IdType="doi">10.1089/lrb.2013.0030</ArticleId>
<ArticleId IdType="pmc">PMC4062108</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001677 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001677 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:24521479
   |texte=   A new soft tissue volume measurement strategy using ultrasonography.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:24521479" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024