Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.

Identifieur interne : 001143 ( PubMed/Corpus ); précédent : 001142; suivant : 001144

Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.

Auteurs : Fredrik Ohberg ; Adam Zachrisson ; Sa Holmner-Rocklöv

Source :

RBID : pubmed:25495382

English descriptors

Abstract

Lymphedema is a common complication following breast cancer treatment, estimated to affect 20% of breast cancer survivors. The condition is associated with a number of symptoms, such as impaired range of motion and anxiety. A wide range of methods for determining the volume of the lymphedematous arm have been described. Circumference measurement (CM) is commonly used in clinics to appraise arm volume, while water displacement (WD) is often used in studies. The aim of the study was to assess the performance of a new method using 3D-technology in comparison to CM and WD.

DOI: 10.1089/lrb.2014.0026
PubMed: 25495382

Links to Exploration step

pubmed:25495382

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.</title>
<author>
<name sortKey="Ohberg, Fredrik" sort="Ohberg, Fredrik" uniqKey="Ohberg F" first="Fredrik" last="Ohberg">Fredrik Ohberg</name>
<affiliation>
<nlm:affiliation>Department of Radiation Sciences, Biomedical Engineering, Umeå University , Umeå, Sweden .</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zachrisson, Adam" sort="Zachrisson, Adam" uniqKey="Zachrisson A" first="Adam" last="Zachrisson">Adam Zachrisson</name>
</author>
<author>
<name sortKey="Holmner Rocklov, Sa" sort="Holmner Rocklov, Sa" uniqKey="Holmner Rocklov " first=" Sa" last="Holmner-Rocklöv"> Sa Holmner-Rocklöv</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:25495382</idno>
<idno type="pmid">25495382</idno>
<idno type="doi">10.1089/lrb.2014.0026</idno>
<idno type="wicri:Area/PubMed/Corpus">001143</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001143</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.</title>
<author>
<name sortKey="Ohberg, Fredrik" sort="Ohberg, Fredrik" uniqKey="Ohberg F" first="Fredrik" last="Ohberg">Fredrik Ohberg</name>
<affiliation>
<nlm:affiliation>Department of Radiation Sciences, Biomedical Engineering, Umeå University , Umeå, Sweden .</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zachrisson, Adam" sort="Zachrisson, Adam" uniqKey="Zachrisson A" first="Adam" last="Zachrisson">Adam Zachrisson</name>
</author>
<author>
<name sortKey="Holmner Rocklov, Sa" sort="Holmner Rocklov, Sa" uniqKey="Holmner Rocklov " first=" Sa" last="Holmner-Rocklöv"> Sa Holmner-Rocklöv</name>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Arm (pathology)</term>
<term>Body Water</term>
<term>Breast Neoplasms (complications)</term>
<term>Breast Neoplasms (therapy)</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Imaging, Three-Dimensional (instrumentation)</term>
<term>Imaging, Three-Dimensional (methods)</term>
<term>Lymphedema (diagnosis)</term>
<term>Lymphedema (etiology)</term>
<term>Middle Aged</term>
<term>Prognosis</term>
</keywords>
<keywords scheme="MESH" qualifier="complications" xml:lang="en">
<term>Breast Neoplasms</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Imaging, Three-Dimensional</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Imaging, Three-Dimensional</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Arm</term>
</keywords>
<keywords scheme="MESH" qualifier="therapy" xml:lang="en">
<term>Breast Neoplasms</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Body Water</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Middle Aged</term>
<term>Prognosis</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Lymphedema is a common complication following breast cancer treatment, estimated to affect 20% of breast cancer survivors. The condition is associated with a number of symptoms, such as impaired range of motion and anxiety. A wide range of methods for determining the volume of the lymphedematous arm have been described. Circumference measurement (CM) is commonly used in clinics to appraise arm volume, while water displacement (WD) is often used in studies. The aim of the study was to assess the performance of a new method using 3D-technology in comparison to CM and WD.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">25495382</PMID>
<DateCreated>
<Year>2014</Year>
<Month>12</Month>
<Day>16</Day>
</DateCreated>
<DateCompleted>
<Year>2015</Year>
<Month>08</Month>
<Day>18</Day>
</DateCompleted>
<DateRevised>
<Year>2014</Year>
<Month>12</Month>
<Day>16</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1557-8585</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>12</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2014</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>Lymphatic research and biology</Title>
<ISOAbbreviation>Lymphat Res Biol</ISOAbbreviation>
</Journal>
<ArticleTitle>Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.</ArticleTitle>
<Pagination>
<MedlinePgn>267-74</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1089/lrb.2014.0026</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Lymphedema is a common complication following breast cancer treatment, estimated to affect 20% of breast cancer survivors. The condition is associated with a number of symptoms, such as impaired range of motion and anxiety. A wide range of methods for determining the volume of the lymphedematous arm have been described. Circumference measurement (CM) is commonly used in clinics to appraise arm volume, while water displacement (WD) is often used in studies. The aim of the study was to assess the performance of a new method using 3D-technology in comparison to CM and WD.</AbstractText>
<AbstractText Label="METHODS AND RESULTS" NlmCategory="RESULTS">The study was performed on 25 subjects with lymphedema secondary to breast cancer treatment. Volumetric data from CM, WD, and the 3D-camera were gathered on all subjects. The measurements were performed by two physiotherapists, each subject being measured by one of the physiotherapist. Estimates of differences between the methods was calculated through analyzing the data collected from the three methods using mixed-design analyses of variance. The results indicated a tendency for the 3D-camera to overestimate the volume in comparison the WD by 45.25 mL, 95% confidence interval (CI) -36.31 - 126.82 (p value 0.270). Conversely, CM showed a tendency to underestimate the volume compared to WD (-24.28 mL, CI -99.78 - 51.22, p value 0.521). Thus, no statistically significant difference was found between the methods.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The 3D-camera is a viable method for measuring arm volume, performing on level with the established methods WD and CM.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Ohberg</LastName>
<ForeName>Fredrik</ForeName>
<Initials>F</Initials>
<AffiliationInfo>
<Affiliation>Department of Radiation Sciences, Biomedical Engineering, Umeå University , Umeå, Sweden .</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Zachrisson</LastName>
<ForeName>Adam</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Holmner-Rocklöv</LastName>
<ForeName>Åsa</ForeName>
<Initials>Å</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Lymphat Res Biol</MedlineTA>
<NlmUniqueID>101163587</NlmUniqueID>
<ISSNLinking>1539-6851</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001132" MajorTopicYN="N">Arm</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001834" MajorTopicYN="Y">Body Water</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001943" MajorTopicYN="N">Breast Neoplasms</DescriptorName>
<QualifierName UI="Q000150" MajorTopicYN="Y">complications</QualifierName>
<QualifierName UI="Q000628" MajorTopicYN="N">therapy</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D021621" MajorTopicYN="N">Imaging, Three-Dimensional</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008209" MajorTopicYN="N">Lymphedema</DescriptorName>
<QualifierName UI="Q000175" MajorTopicYN="Y">diagnosis</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011379" MajorTopicYN="N">Prognosis</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2014</Year>
<Month>12</Month>
<Day>16</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2014</Year>
<Month>12</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>8</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">25495382</ArticleId>
<ArticleId IdType="doi">10.1089/lrb.2014.0026</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001143 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001143 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:25495382
   |texte=   Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:25495382" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024