Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Limb circumference measurement for recording edema volume in patients with filarial lymphedema.

Identifieur interne : 004D01 ( PubMed/Checkpoint ); précédent : 004D00; suivant : 004D02

Limb circumference measurement for recording edema volume in patients with filarial lymphedema.

Auteurs : S P Pani ; P. Vanamail ; J. Yuvaraj

Source :

RBID : pubmed:7564492

Descripteurs français

English descriptors

Abstract

To evaluate the impact of therapy and monitor the progression of filarial lymphedema, it is necessary to measure accurately the changes in limb edema volume. In this communication, we report the reliability of circumference measurements for recording volume changes. The measurements included the distal parts of limbs important for filarial lymphedema. In a series of 100 patients with unilateral lower limb lymphedema, both water displacement and circumference measurements were done. The results showed a significant correlation (r = 0.91; P = 0.0000) between the actual volume and that estimated by circumference measurement. Not only could volume of edema be calculated by circumference measurements, but the simple measurement of average circumference difference between the affected and normal limb accurately reflected the volume of actual edema.

PubMed: 7564492


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:7564492

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Limb circumference measurement for recording edema volume in patients with filarial lymphedema.</title>
<author>
<name sortKey="Pani, S P" sort="Pani, S P" uniqKey="Pani S" first="S P" last="Pani">S P Pani</name>
<affiliation>
<nlm:affiliation>Vector Control Research Centre (Indian Council of Medical Research), Indira Nagar, Pondicherry.</nlm:affiliation>
<wicri:noCountry code="subField">Pondicherry</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Vanamail, P" sort="Vanamail, P" uniqKey="Vanamail P" first="P" last="Vanamail">P. Vanamail</name>
</author>
<author>
<name sortKey="Yuvaraj, J" sort="Yuvaraj, J" uniqKey="Yuvaraj J" first="J" last="Yuvaraj">J. Yuvaraj</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:7564492</idno>
<idno type="pmid">7564492</idno>
<idno type="wicri:Area/PubMed/Corpus">005388</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">005388</idno>
<idno type="wicri:Area/PubMed/Curation">005388</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">005388</idno>
<idno type="wicri:Area/PubMed/Checkpoint">005388</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">005388</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Limb circumference measurement for recording edema volume in patients with filarial lymphedema.</title>
<author>
<name sortKey="Pani, S P" sort="Pani, S P" uniqKey="Pani S" first="S P" last="Pani">S P Pani</name>
<affiliation>
<nlm:affiliation>Vector Control Research Centre (Indian Council of Medical Research), Indira Nagar, Pondicherry.</nlm:affiliation>
<wicri:noCountry code="subField">Pondicherry</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Vanamail, P" sort="Vanamail, P" uniqKey="Vanamail P" first="P" last="Vanamail">P. Vanamail</name>
</author>
<author>
<name sortKey="Yuvaraj, J" sort="Yuvaraj, J" uniqKey="Yuvaraj J" first="J" last="Yuvaraj">J. Yuvaraj</name>
</author>
</analytic>
<series>
<title level="j">Lymphology</title>
<idno type="ISSN">0024-7766</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anthropometry (methods)</term>
<term>Elephantiasis, Filarial (pathology)</term>
<term>Humans</term>
<term>Leg (pathology)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Anthropométrie ()</term>
<term>Filariose lymphatique (anatomopathologie)</term>
<term>Humains</term>
<term>Jambe (anatomopathologie)</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomopathologie" xml:lang="fr">
<term>Filariose lymphatique</term>
<term>Jambe</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Anthropometry</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Elephantiasis, Filarial</term>
<term>Leg</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Anthropométrie</term>
<term>Humains</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate the impact of therapy and monitor the progression of filarial lymphedema, it is necessary to measure accurately the changes in limb edema volume. In this communication, we report the reliability of circumference measurements for recording volume changes. The measurements included the distal parts of limbs important for filarial lymphedema. In a series of 100 patients with unilateral lower limb lymphedema, both water displacement and circumference measurements were done. The results showed a significant correlation (r = 0.91; P = 0.0000) between the actual volume and that estimated by circumference measurement. Not only could volume of edema be calculated by circumference measurements, but the simple measurement of average circumference difference between the affected and normal limb accurately reflected the volume of actual edema.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">7564492</PMID>
<DateCreated>
<Year>1995</Year>
<Month>10</Month>
<Day>24</Day>
</DateCreated>
<DateCompleted>
<Year>1995</Year>
<Month>10</Month>
<Day>24</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>03</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0024-7766</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>28</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1995</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Lymphology</Title>
<ISOAbbreviation>Lymphology</ISOAbbreviation>
</Journal>
<ArticleTitle>Limb circumference measurement for recording edema volume in patients with filarial lymphedema.</ArticleTitle>
<Pagination>
<MedlinePgn>57-63</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>To evaluate the impact of therapy and monitor the progression of filarial lymphedema, it is necessary to measure accurately the changes in limb edema volume. In this communication, we report the reliability of circumference measurements for recording volume changes. The measurements included the distal parts of limbs important for filarial lymphedema. In a series of 100 patients with unilateral lower limb lymphedema, both water displacement and circumference measurements were done. The results showed a significant correlation (r = 0.91; P = 0.0000) between the actual volume and that estimated by circumference measurement. Not only could volume of edema be calculated by circumference measurements, but the simple measurement of average circumference difference between the affected and normal limb accurately reflected the volume of actual edema.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Pani</LastName>
<ForeName>S P</ForeName>
<Initials>SP</Initials>
<AffiliationInfo>
<Affiliation>Vector Control Research Centre (Indian Council of Medical Research), Indira Nagar, Pondicherry.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Vanamail</LastName>
<ForeName>P</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Yuvaraj</LastName>
<ForeName>J</ForeName>
<Initials>J</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Lymphology</MedlineTA>
<NlmUniqueID>0155112</NlmUniqueID>
<ISSNLinking>0024-7766</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000886" MajorTopicYN="N">Anthropometry</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004605" MajorTopicYN="N">Elephantiasis, Filarial</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007866" MajorTopicYN="N">Leg</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">7564492</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Pani, S P" sort="Pani, S P" uniqKey="Pani S" first="S P" last="Pani">S P Pani</name>
<name sortKey="Vanamail, P" sort="Vanamail, P" uniqKey="Vanamail P" first="P" last="Vanamail">P. Vanamail</name>
<name sortKey="Yuvaraj, J" sort="Yuvaraj, J" uniqKey="Yuvaraj J" first="J" last="Yuvaraj">J. Yuvaraj</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004D01 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 004D01 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:7564492
   |texte=   Limb circumference measurement for recording edema volume in patients with filarial lymphedema.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:7564492" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024