Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.

Identifieur interne : 002923 ( PubMed/Checkpoint ); précédent : 002922; suivant : 002924

Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.

Auteurs : M. Hirai [Japon] ; K. Niimi ; H. Iwata ; I. Sugimoto ; H. Ishibashi ; T. Ota ; H. Nakamura

Source :

RBID : pubmed:20656958

Descripteurs français

English descriptors

Abstract

To compare the interface pressure during rest and exercise among various kinds of arm sleeves.

DOI: 10.1258/phleb.2009.009064
PubMed: 20656958


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:20656958

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.</title>
<author>
<name sortKey="Hirai, M" sort="Hirai, M" uniqKey="Hirai M" first="M" last="Hirai">M. Hirai</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Vascular Surgery, Tohkai Hospital, Nagoya, Japan. hiraimh@yahoo.co.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Vascular Surgery, Tohkai Hospital, Nagoya</wicri:regionArea>
<wicri:noRegion>Nagoya</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Niimi, K" sort="Niimi, K" uniqKey="Niimi K" first="K" last="Niimi">K. Niimi</name>
</author>
<author>
<name sortKey="Iwata, H" sort="Iwata, H" uniqKey="Iwata H" first="H" last="Iwata">H. Iwata</name>
</author>
<author>
<name sortKey="Sugimoto, I" sort="Sugimoto, I" uniqKey="Sugimoto I" first="I" last="Sugimoto">I. Sugimoto</name>
</author>
<author>
<name sortKey="Ishibashi, H" sort="Ishibashi, H" uniqKey="Ishibashi H" first="H" last="Ishibashi">H. Ishibashi</name>
</author>
<author>
<name sortKey="Ota, T" sort="Ota, T" uniqKey="Ota T" first="T" last="Ota">T. Ota</name>
</author>
<author>
<name sortKey="Nakamura, H" sort="Nakamura, H" uniqKey="Nakamura H" first="H" last="Nakamura">H. Nakamura</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="RBID">pubmed:20656958</idno>
<idno type="pmid">20656958</idno>
<idno type="doi">10.1258/phleb.2009.009064</idno>
<idno type="wicri:Area/PubMed/Corpus">002976</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002976</idno>
<idno type="wicri:Area/PubMed/Curation">002976</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002976</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002976</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002976</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.</title>
<author>
<name sortKey="Hirai, M" sort="Hirai, M" uniqKey="Hirai M" first="M" last="Hirai">M. Hirai</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Vascular Surgery, Tohkai Hospital, Nagoya, Japan. hiraimh@yahoo.co.jp</nlm:affiliation>
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Vascular Surgery, Tohkai Hospital, Nagoya</wicri:regionArea>
<wicri:noRegion>Nagoya</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Niimi, K" sort="Niimi, K" uniqKey="Niimi K" first="K" last="Niimi">K. Niimi</name>
</author>
<author>
<name sortKey="Iwata, H" sort="Iwata, H" uniqKey="Iwata H" first="H" last="Iwata">H. Iwata</name>
</author>
<author>
<name sortKey="Sugimoto, I" sort="Sugimoto, I" uniqKey="Sugimoto I" first="I" last="Sugimoto">I. Sugimoto</name>
</author>
<author>
<name sortKey="Ishibashi, H" sort="Ishibashi, H" uniqKey="Ishibashi H" first="H" last="Ishibashi">H. Ishibashi</name>
</author>
<author>
<name sortKey="Ota, T" sort="Ota, T" uniqKey="Ota T" first="T" last="Ota">T. Ota</name>
</author>
<author>
<name sortKey="Nakamura, H" sort="Nakamura, H" uniqKey="Nakamura H" first="H" last="Nakamura">H. Nakamura</name>
</author>
</analytic>
<series>
<title level="j">Phlebology</title>
<idno type="eISSN">1758-1125</idno>
<imprint>
<date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Arm (blood supply)</term>
<term>Arm (physiology)</term>
<term>Bandages</term>
<term>Elasticity</term>
<term>Exercise (physiology)</term>
<term>Female</term>
<term>Humans</term>
<term>Lymphedema (physiopathology)</term>
<term>Lymphedema (therapy)</term>
<term>Materials Testing</term>
<term>Muscle, Skeletal (blood supply)</term>
<term>Muscle, Skeletal (physiology)</term>
<term>Pressure</term>
<term>Regional Blood Flow (physiology)</term>
<term>Rest (physiology)</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Bandages</term>
<term>Bras ()</term>
<term>Bras (physiologie)</term>
<term>Débit sanguin régional (physiologie)</term>
<term>Exercice physique (physiologie)</term>
<term>Femelle</term>
<term>Humains</term>
<term>Jeune adulte</term>
<term>Lymphoedème ()</term>
<term>Lymphoedème (physiopathologie)</term>
<term>Muscles squelettiques ()</term>
<term>Muscles squelettiques (physiologie)</term>
<term>Pression</term>
<term>Repos (physiologie)</term>
<term>Test de matériaux</term>
<term>Élasticité</term>
</keywords>
<keywords scheme="MESH" qualifier="blood supply" xml:lang="en">
<term>Arm</term>
<term>Muscle, Skeletal</term>
</keywords>
<keywords scheme="MESH" qualifier="physiologie" xml:lang="fr">
<term>Bras</term>
<term>Débit sanguin régional</term>
<term>Exercice physique</term>
<term>Muscles squelettiques</term>
<term>Repos</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Arm</term>
<term>Exercise</term>
<term>Muscle, Skeletal</term>
<term>Regional Blood Flow</term>
<term>Rest</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Lymphoedème</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="therapy" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Bandages</term>
<term>Elasticity</term>
<term>Female</term>
<term>Humans</term>
<term>Materials Testing</term>
<term>Pressure</term>
<term>Young Adult</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Bandages</term>
<term>Bras</term>
<term>Femelle</term>
<term>Humains</term>
<term>Jeune adulte</term>
<term>Lymphoedème</term>
<term>Muscles squelettiques</term>
<term>Pression</term>
<term>Test de matériaux</term>
<term>Élasticité</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To compare the interface pressure during rest and exercise among various kinds of arm sleeves.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">20656958</PMID>
<DateCreated>
<Year>2010</Year>
<Month>07</Month>
<Day>26</Day>
</DateCreated>
<DateCompleted>
<Year>2010</Year>
<Month>11</Month>
<Day>05</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>10</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1758-1125</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>25</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2010</Year>
<Month>Aug</Month>
</PubDate>
</JournalIssue>
<Title>Phlebology</Title>
<ISOAbbreviation>Phlebology</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.</ArticleTitle>
<Pagination>
<MedlinePgn>196-200</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1258/phleb.2009.009064</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVES" NlmCategory="OBJECTIVE">To compare the interface pressure during rest and exercise among various kinds of arm sleeves.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">The interface pressure underneath nine different arm sleeves was measured during 10 maximal opening and closing movements of fingers using a pressure transducer (Air Pack Type Analyser) in 16 healthy volunteers. Furthermore, in order to evaluate the characteristics of each arm sleeve, the extensibility, stiffness and thickness were determined in vitro by several apparatuses.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There was a significant correlation between stiffness and extensibility. The stiffness was significantly correlated with the pressure difference between muscle contraction and relaxation during exercise. The higher the value of stiffness, the greater the pressure amplitude during exercise.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Short-stretch arm sleeves characterized with a high level stiffness, including thick round- and flat-knitted arm sleeves, are more beneficial for the augmentation of muscle pumping than long-stretch arm sleeves, in the same way as short-stretch bandages or stockings applied to the leg.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Hirai</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Department of Vascular Surgery, Tohkai Hospital, Nagoya, Japan. hiraimh@yahoo.co.jp</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Niimi</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Iwata</LastName>
<ForeName>H</ForeName>
<Initials>H</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Sugimoto</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ishibashi</LastName>
<ForeName>H</ForeName>
<Initials>H</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ota</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Nakamura</LastName>
<ForeName>H</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Phlebology</MedlineTA>
<NlmUniqueID>9012921</NlmUniqueID>
<ISSNLinking>0268-3555</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D001132" MajorTopicYN="N">Arm</DescriptorName>
<QualifierName UI="Q000098" MajorTopicYN="Y">blood supply</QualifierName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001458" MajorTopicYN="Y">Bandages</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004548" MajorTopicYN="N">Elasticity</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015444" MajorTopicYN="N">Exercise</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008209" MajorTopicYN="N">Lymphedema</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
<QualifierName UI="Q000628" MajorTopicYN="N">therapy</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008422" MajorTopicYN="N">Materials Testing</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D018482" MajorTopicYN="N">Muscle, Skeletal</DescriptorName>
<QualifierName UI="Q000098" MajorTopicYN="N">blood supply</QualifierName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011312" MajorTopicYN="Y">Pressure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012039" MajorTopicYN="N">Regional Blood Flow</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012146" MajorTopicYN="N">Rest</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D055815" MajorTopicYN="N">Young Adult</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2010</Year>
<Month>7</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2010</Year>
<Month>7</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2010</Year>
<Month>11</Month>
<Day>6</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">20656958</ArticleId>
<ArticleId IdType="pii">25/4/196</ArticleId>
<ArticleId IdType="doi">10.1258/phleb.2009.009064</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Ishibashi, H" sort="Ishibashi, H" uniqKey="Ishibashi H" first="H" last="Ishibashi">H. Ishibashi</name>
<name sortKey="Iwata, H" sort="Iwata, H" uniqKey="Iwata H" first="H" last="Iwata">H. Iwata</name>
<name sortKey="Nakamura, H" sort="Nakamura, H" uniqKey="Nakamura H" first="H" last="Nakamura">H. Nakamura</name>
<name sortKey="Niimi, K" sort="Niimi, K" uniqKey="Niimi K" first="K" last="Niimi">K. Niimi</name>
<name sortKey="Ota, T" sort="Ota, T" uniqKey="Ota T" first="T" last="Ota">T. Ota</name>
<name sortKey="Sugimoto, I" sort="Sugimoto, I" uniqKey="Sugimoto I" first="I" last="Sugimoto">I. Sugimoto</name>
</noCountry>
<country name="Japon">
<noRegion>
<name sortKey="Hirai, M" sort="Hirai, M" uniqKey="Hirai M" first="M" last="Hirai">M. Hirai</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002923 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 002923 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:20656958
   |texte=   Comparison of stiffness and interface pressure during rest and exercise among various arm sleeves.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:20656958" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024