Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Mechanical Forces and Lymphatic Transport

Identifieur interne : 003271 ( Pmc/Corpus ); précédent : 003270; suivant : 003272

Mechanical Forces and Lymphatic Transport

Auteurs : Jerome W. Breslin

Source :

RBID : PMC:4267889

Abstract

This review examines current understanding of how the lymphatic vessel network can optimize lymph flow in response to various mechanical forces. Lymphatics are organized as a vascular tree, with blind-ended initial lymphatics, precollectors, prenodal collecting lymphatics, lymph nodes, postnodal collecting lymphatics and the larger trunks (thoracic duct and right lymph duct) that connect to the subclavian veins. The formation of lymph from interstitial fluid depends heavily on oscillating pressure gradients to drive fluid into initial lymphatics. Collecting lymphatics are segmented vessels with unidirectional valves, with each segment, called a lymphangion, possessing an intrinsic pumping mechanism. The lymphangions propel lymph forward against a hydrostatic pressure gradient. Fluid is returned to the central circulation both at lymph nodes and via the larger lymphatic trunks. Several recent developments are discussed, including: evidence for the active role of endothelial cells in lymph formation; recent developments on how inflow pressure, outflow pressure, and shear stress affect pump function of the lymphangion; lymphatic valve gating mechanisms; collecting lymphatic permeability; and current interpretations of the molecular mechanisms within lymphatic endothelial cells and smooth muscle. Improved understanding of the physiological mechanisms by lymphatic vessels sense mechanical stimuli, integrate the information, and generate the appropriate response is key for determining the pathogenesis of lymphatic insufficiency and developing treatments for lymphedema.


Url:
DOI: 10.1016/j.mvr.2014.07.013
PubMed: 25107458
PubMed Central: 4267889

Links to Exploration step

PMC:4267889

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Mechanical Forces and Lymphatic Transport</title>
<author>
<name sortKey="Breslin, Jerome W" sort="Breslin, Jerome W" uniqKey="Breslin J" first="Jerome W." last="Breslin">Jerome W. Breslin</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">25107458</idno>
<idno type="pmc">4267889</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4267889</idno>
<idno type="RBID">PMC:4267889</idno>
<idno type="doi">10.1016/j.mvr.2014.07.013</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">003271</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">003271</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Mechanical Forces and Lymphatic Transport</title>
<author>
<name sortKey="Breslin, Jerome W" sort="Breslin, Jerome W" uniqKey="Breslin J" first="Jerome W." last="Breslin">Jerome W. Breslin</name>
</author>
</analytic>
<series>
<title level="j">Microvascular research</title>
<idno type="ISSN">0026-2862</idno>
<idno type="eISSN">1095-9319</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P2">This review examines current understanding of how the lymphatic vessel network can optimize lymph flow in response to various mechanical forces. Lymphatics are organized as a vascular tree, with blind-ended initial lymphatics, precollectors, prenodal collecting lymphatics, lymph nodes, postnodal collecting lymphatics and the larger trunks (thoracic duct and right lymph duct) that connect to the subclavian veins. The formation of lymph from interstitial fluid depends heavily on oscillating pressure gradients to drive fluid into initial lymphatics. Collecting lymphatics are segmented vessels with unidirectional valves, with each segment, called a lymphangion, possessing an intrinsic pumping mechanism. The lymphangions propel lymph forward against a hydrostatic pressure gradient. Fluid is returned to the central circulation both at lymph nodes and via the larger lymphatic trunks. Several recent developments are discussed, including: evidence for the active role of endothelial cells in lymph formation; recent developments on how inflow pressure, outflow pressure, and shear stress affect pump function of the lymphangion; lymphatic valve gating mechanisms; collecting lymphatic permeability; and current interpretations of the molecular mechanisms within lymphatic endothelial cells and smooth muscle. Improved understanding of the physiological mechanisms by lymphatic vessels sense mechanical stimuli, integrate the information, and generate the appropriate response is key for determining the pathogenesis of lymphatic insufficiency and developing treatments for lymphedema.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<pmc-dir>properties manuscript</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-journal-id">0165035</journal-id>
<journal-id journal-id-type="pubmed-jr-id">5805</journal-id>
<journal-id journal-id-type="nlm-ta">Microvasc Res</journal-id>
<journal-id journal-id-type="iso-abbrev">Microvasc. Res.</journal-id>
<journal-title-group>
<journal-title>Microvascular research</journal-title>
</journal-title-group>
<issn pub-type="ppub">0026-2862</issn>
<issn pub-type="epub">1095-9319</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">25107458</article-id>
<article-id pub-id-type="pmc">4267889</article-id>
<article-id pub-id-type="doi">10.1016/j.mvr.2014.07.013</article-id>
<article-id pub-id-type="manuscript">NIHMS624732</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Mechanical Forces and Lymphatic Transport</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Breslin</surname>
<given-names>Jerome W.</given-names>
</name>
<aff id="A1">Department of Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL</aff>
</contrib>
</contrib-group>
<author-notes>
<corresp id="FN1">Address Correspondence to: Jerome W. Breslin, PhD, Associate Professor, Molecular Pharmacology and Physiology, University of South Florida, 12901 Bruce B Downs Blvd MDC8, Tampa, FL 33612, +1 (813) 974-7631,
<email>jbreslin@health.usf.edu</email>
</corresp>
</author-notes>
<pub-date pub-type="nihms-submitted">
<day>9</day>
<month>9</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>5</day>
<month>8</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="ppub">
<month>11</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>01</day>
<month>11</month>
<year>2015</year>
</pub-date>
<volume>0</volume>
<fpage>46</fpage>
<lpage>54</lpage>
<pmc-comment>elocation-id from pubmed: 10.1016/j.mvr.2014.07.013</pmc-comment>
<permissions>
<copyright-statement>© 2014 Elsevier Inc. All rights reserved.</copyright-statement>
<copyright-year>2014</copyright-year>
</permissions>
<abstract>
<p id="P2">This review examines current understanding of how the lymphatic vessel network can optimize lymph flow in response to various mechanical forces. Lymphatics are organized as a vascular tree, with blind-ended initial lymphatics, precollectors, prenodal collecting lymphatics, lymph nodes, postnodal collecting lymphatics and the larger trunks (thoracic duct and right lymph duct) that connect to the subclavian veins. The formation of lymph from interstitial fluid depends heavily on oscillating pressure gradients to drive fluid into initial lymphatics. Collecting lymphatics are segmented vessels with unidirectional valves, with each segment, called a lymphangion, possessing an intrinsic pumping mechanism. The lymphangions propel lymph forward against a hydrostatic pressure gradient. Fluid is returned to the central circulation both at lymph nodes and via the larger lymphatic trunks. Several recent developments are discussed, including: evidence for the active role of endothelial cells in lymph formation; recent developments on how inflow pressure, outflow pressure, and shear stress affect pump function of the lymphangion; lymphatic valve gating mechanisms; collecting lymphatic permeability; and current interpretations of the molecular mechanisms within lymphatic endothelial cells and smooth muscle. Improved understanding of the physiological mechanisms by lymphatic vessels sense mechanical stimuli, integrate the information, and generate the appropriate response is key for determining the pathogenesis of lymphatic insufficiency and developing treatments for lymphedema.</p>
</abstract>
<kwd-group>
<kwd>Lymphatic endothelium</kwd>
<kwd>lymphatic muscle</kwd>
<kwd>lymphatic myogenic response</kwd>
<kwd>lymphatic contractile cycle</kwd>
<kwd>lymphedema</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003271 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 003271 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4267889
   |texte=   Mechanical Forces and Lymphatic Transport
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:25107458" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024