Abstract

Abstract

Background: A significant percentage of breast cancer survivors are at risk for lymphedema for which lifelong self-care is required. Previous studies suggest that less than 50% of breast cancer survivors with lymphedema (BCS-LE) perform prescribed self-care tasks and that even wearing a compression sleeve, the most commonly reported self-care activity, is done irregularly. Reasons for poor self-care adherence include perceived lack of results from self-care (no available arm volume data) and perceived inability to manage the condition.

Methods and Results: A two-part pilot study was conducted to: 1) develop and determine the feasibility of a self-measurement protocol using a single frequency bioelectrical impedance device; and 2) examine daily variation in extracellular volume in healthy and lymphedematous limbs. Healthy and BCS-LE volunteers were recruited to refine and test a self-measurement protocol. Volunteers were trained in the use of the device and measured for 5 consecutive days in a laboratory setting. They were then given the device to use at home for an additional 5 consecutive days of self-measurement. All volunteers completed each scheduled home measurement. Daily variability in both groups was noted.

Conclusions: Home self-measurement using bioelectrical impedance is feasible, acceptable, and captures change. This has implications for both self-care support and for the possibility of incorporating self-measurement using bioelectrical impedance in future clinical trials examining effectiveness of lymphedema treatment.


Url:
DOI: 10.1089/lrb.2013.0020
PubMed: 24502422
PubMed Central: 3961792

Links to Exploration step

PMC:3961792

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Bioelectrical Impedance Self-Measurement Protocol Development and Daily Variation Between Healthy Volunteers and Breast Cancer Survivors with Lymphedema</title>
<author>
<name sortKey="Ridner, Sheila H" sort="Ridner, Sheila H" uniqKey="Ridner S" first="Sheila H." last="Ridner">Sheila H. Ridner</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Bonner, Candace M" sort="Bonner, Candace M" uniqKey="Bonner C" first="Candace M." last="Bonner">Candace M. Bonner</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Doersam, Jennifer K" sort="Doersam, Jennifer K" uniqKey="Doersam J" first="Jennifer K." last="Doersam">Jennifer K. Doersam</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Rhoten, Bethany A" sort="Rhoten, Bethany A" uniqKey="Rhoten B" first="Bethany A." last="Rhoten">Bethany A. Rhoten</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Schultze, Benjamin" sort="Schultze, Benjamin" uniqKey="Schultze B" first="Benjamin" last="Schultze">Benjamin Schultze</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Dietrich, Mary S" sort="Dietrich, Mary S" uniqKey="Dietrich M" first="Mary S." last="Dietrich">Mary S. Dietrich</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24502422</idno>
<idno type="pmc">3961792</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3961792</idno>
<idno type="RBID">PMC:3961792</idno>
<idno type="doi">10.1089/lrb.2013.0020</idno>
<date when="2014">2014</date>
<idno type="wicri:Area/Pmc/Corpus">003039</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">003039</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Bioelectrical Impedance Self-Measurement Protocol Development and Daily Variation Between Healthy Volunteers and Breast Cancer Survivors with Lymphedema</title>
<author>
<name sortKey="Ridner, Sheila H" sort="Ridner, Sheila H" uniqKey="Ridner S" first="Sheila H." last="Ridner">Sheila H. Ridner</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Bonner, Candace M" sort="Bonner, Candace M" uniqKey="Bonner C" first="Candace M." last="Bonner">Candace M. Bonner</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Doersam, Jennifer K" sort="Doersam, Jennifer K" uniqKey="Doersam J" first="Jennifer K." last="Doersam">Jennifer K. Doersam</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Rhoten, Bethany A" sort="Rhoten, Bethany A" uniqKey="Rhoten B" first="Bethany A." last="Rhoten">Bethany A. Rhoten</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Schultze, Benjamin" sort="Schultze, Benjamin" uniqKey="Schultze B" first="Benjamin" last="Schultze">Benjamin Schultze</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Dietrich, Mary S" sort="Dietrich, Mary S" uniqKey="Dietrich M" first="Mary S." last="Dietrich">Mary S. Dietrich</name>
<affiliation>
<nlm:aff id="aff1"></nlm:aff>
</affiliation>
<affiliation>
<nlm:aff id="aff2"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Lymphatic Research and Biology</title>
<idno type="ISSN">1539-6851</idno>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2014">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<title>Abstract</title>
<p>
<bold>
<italic>Background:</italic>
</bold>
A significant percentage of breast cancer survivors are at risk for lymphedema for which lifelong self-care is required. Previous studies suggest that less than 50% of breast cancer survivors with lymphedema (BCS-LE) perform prescribed self-care tasks and that even wearing a compression sleeve, the most commonly reported self-care activity, is done irregularly. Reasons for poor self-care adherence include perceived lack of results from self-care (no available arm volume data) and perceived inability to manage the condition.</p>
<p>
<bold>
<italic>Methods and Results:</italic>
</bold>
A two-part pilot study was conducted to: 1) develop and determine the feasibility of a self-measurement protocol using a single frequency bioelectrical impedance device; and 2) examine daily variation in extracellular volume in healthy and lymphedematous limbs. Healthy and BCS-LE volunteers were recruited to refine and test a self-measurement protocol. Volunteers were trained in the use of the device and measured for 5 consecutive days in a laboratory setting. They were then given the device to use at home for an additional 5 consecutive days of self-measurement. All volunteers completed each scheduled home measurement. Daily variability in both groups was noted.</p>
<p>
<bold>
<italic>Conclusions:</italic>
</bold>
Home self-measurement using bioelectrical impedance is feasible, acceptable, and captures change. This has implications for both self-care support and for the possibility of incorporating self-measurement using bioelectrical impedance in future clinical trials examining effectiveness of lymphedema treatment.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Lymphat Res Biol</journal-id>
<journal-id journal-id-type="iso-abbrev">Lymphat Res Biol</journal-id>
<journal-id journal-id-type="publisher-id">lrb</journal-id>
<journal-title-group>
<journal-title>Lymphatic Research and Biology</journal-title>
</journal-title-group>
<issn pub-type="ppub">1539-6851</issn>
<issn pub-type="epub">1557-8585</issn>
<publisher>
<publisher-name>Mary Ann Liebert, Inc.</publisher-name>
<publisher-loc>140 Huguenot Street, 3rd FloorNew Rochelle, NY 10801USA</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">24502422</article-id>
<article-id pub-id-type="pmc">3961792</article-id>
<article-id pub-id-type="publisher-id">10.1089/lrb.2013.0020</article-id>
<article-id pub-id-type="doi">10.1089/lrb.2013.0020</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Articles</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Bioelectrical Impedance Self-Measurement Protocol Development and Daily Variation Between Healthy Volunteers and Breast Cancer Survivors with Lymphedema</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ridner</surname>
<given-names>Sheila H.</given-names>
</name>
<degrees>PhD, RN, FAAN</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Bonner</surname>
<given-names>Candace M.</given-names>
</name>
<degrees>BS, RN</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Doersam</surname>
<given-names>Jennifer K.</given-names>
</name>
<degrees>BS</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Rhoten</surname>
<given-names>Bethany A.</given-names>
</name>
<degrees>PhD, RN</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Schultze</surname>
<given-names>Benjamin</given-names>
</name>
<degrees>MSN, RN</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Dietrich</surname>
<given-names>Mary S.</given-names>
</name>
<degrees>PhD</degrees>
<xref ref-type="aff" rid="aff1">
<sup>1,</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<aff id="aff1">
<label>
<sup>1</sup>
</label>
School of Nursing,
<institution>Vanderbilt University</institution>
, Nashville, Tennessee.</aff>
<aff id="aff2">
<label>
<sup>2</sup>
</label>
School of Medicine,
<institution>Vanderbilt University</institution>
, Nashville, Tennessee.</aff>
</contrib-group>
<author-notes>
<corresp>
<addr-line>Address correspondence to:</addr-line>
<addr-line>
<italic>Sheila H. Ridner, PhD, RN, FAAN</italic>
</addr-line>
<institution>
<italic>Vanderbilt University School of Nursing</italic>
</institution>
<addr-line>
<italic>525 Godchaux Hall</italic>
</addr-line>
<addr-line>
<italic>461 21
<sup>st</sup>
Ave. South</italic>
</addr-line>
<addr-line>
<italic>Nashville, TN 37240</italic>
</addr-line>
<italic>E-mail:</italic>
<email xlink:href="mailto:Sheila.Ridner@Vanderbilt.edu">Sheila.Ridner@Vanderbilt.edu</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<day>01</day>
<month>3</month>
<year>2014</year>
<pmc-comment>string-date: March 2014</pmc-comment>
</pub-date>
<volume>12</volume>
<issue>1</issue>
<fpage>2</fpage>
<lpage>9</lpage>
<permissions>
<copyright-statement>Copyright 2014, Mary Ann Liebert, Inc.</copyright-statement>
<copyright-year>2014</copyright-year>
</permissions>
<self-uri content-type="pdf" xlink:type="simple" xlink:href="lrb.2013.0020.pdf"></self-uri>
<abstract>
<title>Abstract</title>
<p>
<bold>
<italic>Background:</italic>
</bold>
A significant percentage of breast cancer survivors are at risk for lymphedema for which lifelong self-care is required. Previous studies suggest that less than 50% of breast cancer survivors with lymphedema (BCS-LE) perform prescribed self-care tasks and that even wearing a compression sleeve, the most commonly reported self-care activity, is done irregularly. Reasons for poor self-care adherence include perceived lack of results from self-care (no available arm volume data) and perceived inability to manage the condition.</p>
<p>
<bold>
<italic>Methods and Results:</italic>
</bold>
A two-part pilot study was conducted to: 1) develop and determine the feasibility of a self-measurement protocol using a single frequency bioelectrical impedance device; and 2) examine daily variation in extracellular volume in healthy and lymphedematous limbs. Healthy and BCS-LE volunteers were recruited to refine and test a self-measurement protocol. Volunteers were trained in the use of the device and measured for 5 consecutive days in a laboratory setting. They were then given the device to use at home for an additional 5 consecutive days of self-measurement. All volunteers completed each scheduled home measurement. Daily variability in both groups was noted.</p>
<p>
<bold>
<italic>Conclusions:</italic>
</bold>
Home self-measurement using bioelectrical impedance is feasible, acceptable, and captures change. This has implications for both self-care support and for the possibility of incorporating self-measurement using bioelectrical impedance in future clinical trials examining effectiveness of lymphedema treatment.</p>
</abstract>
<counts>
<fig-count count="3"></fig-count>
<table-count count="5"></table-count>
<ref-count count="28"></ref-count>
<page-count count="8"></page-count>
</counts>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003039 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 003039 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:3961792
   |texte=   Bioelectrical Impedance Self-Measurement Protocol Development and Daily Variation Between Healthy Volunteers and Breast Cancer Survivors with Lymphedema
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:24502422" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024