Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema

Identifieur interne : 000252 ( PascalFrancis/Curation ); précédent : 000251; suivant : 000253

Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema

Auteurs : A. Moseley [Australie] ; N. Piller [Australie] ; C. Carati [Australie]

Source :

RBID : Pascal:03-0132623

Descripteurs français

English descriptors

Abstract

Secondary lymphedema of the legs is a common sequela of patients treated for cancer of the reproductive, gastrointestinal, urinary systems and melanoma. From a clinical and research perspective it is of utmost importance to use techniques that objectively quantify leg volume and fluid composition as an indicator of lymphedema severity and response to treatment. Two techniques often used in both the clinical and research setting are leg perometry and multi-frequency bioimpedance. Although both techniques have been extensively validated, this trial aimed to cross correlate both measurement techniques to ascertain whether each or both could be used reliably for measurement of leg lymphedema. These measurements were utilized throughout a clinical trial that assessed the effectiveness of a new home based treatment program in the form of the Sun Ancon Aerobic Exerciser®. This machine delivered both elevation and passive exercise to the legs, with participants using the machine over a three week period during which time their leg volumes were measured using both perometry and bioimpedance. The results demonstrated that leg volume measurements decreased using both perometry and bioimpedance. The reduction in body extracellular fluid as measured by bioimpedance correlated well with a reduction in leg volume as measured by perometry. Bioimpedance also recorded a reduction in weight, which was correlated with the reduction in leg volume as measured by perometry. This trial confirms that perometry and bioimpedance were both effective in independently showing a reduction in leg lymphedema using the Aerobic Exerciser therapy, and that both methods can be reliably used to measure and follow leg lymphedema.
pA  
A01 01  1    @0 0024-7766
A02 01      @0 LYMPBN
A03   1    @0 Lymphology
A05       @2 35
A06       @2 4
A08 01  1  ENG  @1 Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema
A11 01  1    @1 MOSELEY (A.)
A11 02  1    @1 PILLER (N.)
A11 03  1    @1 CARATI (C.)
A14 01      @1 Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park @2 Adelaide, South Australia @3 AUS @Z 1 aut. @Z 2 aut. @Z 3 aut.
A20       @1 136-143
A21       @1 2002
A23 01      @0 ENG
A43 01      @1 INIST @2 14604 @5 354000103813750010
A44       @0 0000 @1 © 2003 INIST-CNRS. All rights reserved.
A45       @0 26 ref.
A47 01  1    @0 03-0132623
A60       @1 P
A61       @0 A
A64 01  1    @0 Lymphology
A66 01      @0 USA
C01 01    ENG  @0 Secondary lymphedema of the legs is a common sequela of patients treated for cancer of the reproductive, gastrointestinal, urinary systems and melanoma. From a clinical and research perspective it is of utmost importance to use techniques that objectively quantify leg volume and fluid composition as an indicator of lymphedema severity and response to treatment. Two techniques often used in both the clinical and research setting are leg perometry and multi-frequency bioimpedance. Although both techniques have been extensively validated, this trial aimed to cross correlate both measurement techniques to ascertain whether each or both could be used reliably for measurement of leg lymphedema. These measurements were utilized throughout a clinical trial that assessed the effectiveness of a new home based treatment program in the form of the Sun Ancon Aerobic Exerciser®. This machine delivered both elevation and passive exercise to the legs, with participants using the machine over a three week period during which time their leg volumes were measured using both perometry and bioimpedance. The results demonstrated that leg volume measurements decreased using both perometry and bioimpedance. The reduction in body extracellular fluid as measured by bioimpedance correlated well with a reduction in leg volume as measured by perometry. Bioimpedance also recorded a reduction in weight, which was correlated with the reduction in leg volume as measured by perometry. This trial confirms that perometry and bioimpedance were both effective in independently showing a reduction in leg lymphedema using the Aerobic Exerciser therapy, and that both methods can be reliably used to measure and follow leg lymphedema.
C02 01  X    @0 002B12B04
C03 01  X  FRE  @0 Lymphoedème @5 01
C03 01  X  ENG  @0 Lymphedema @5 01
C03 01  X  SPA  @0 Linfedema @5 01
C03 02  X  FRE  @0 Jambe @5 02
C03 02  X  ENG  @0 Leg @5 02
C03 02  X  SPA  @0 Pierna @5 02
C03 03  X  FRE  @0 Chronique @5 03
C03 03  X  ENG  @0 Chronic @5 03
C03 03  X  SPA  @0 Crónico @5 03
C03 04  X  FRE  @0 Dispositif optoélectronique @5 04
C03 04  X  ENG  @0 Optoelectronic device @5 04
C03 04  X  SPA  @0 Dispositivo optoelectrónico @5 04
C03 05  X  FRE  @0 Impédancemétrie @5 07
C03 05  X  ENG  @0 Impedancemetry @5 07
C03 05  X  SPA  @0 Impedanciometría @5 07
C03 06  X  FRE  @0 Diagnostic @5 17
C03 06  X  ENG  @0 Diagnosis @5 17
C03 06  X  SPA  @0 Diagnóstico @5 17
C03 07  X  FRE  @0 Homme @5 20
C03 07  X  ENG  @0 Human @5 20
C03 07  X  SPA  @0 Hombre @5 20
C07 01  X  FRE  @0 Appareil circulatoire pathologie @5 37
C07 01  X  ENG  @0 Cardiovascular disease @5 37
C07 01  X  SPA  @0 Aparato circulatorio patología @5 37
C07 02  X  FRE  @0 Lymphatique pathologie @5 38
C07 02  X  ENG  @0 Lymphatic vessel disease @5 38
C07 02  X  SPA  @0 Linfático patología @5 38
N21       @1 076
N82       @1 PSI

Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:03-0132623

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema</title>
<author>
<name sortKey="Moseley, A" sort="Moseley, A" uniqKey="Moseley A" first="A." last="Moseley">A. Moseley</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
<author>
<name sortKey="Piller, N" sort="Piller, N" uniqKey="Piller N" first="N." last="Piller">N. Piller</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
<author>
<name sortKey="Carati, C" sort="Carati, C" uniqKey="Carati C" first="C." last="Carati">C. Carati</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">03-0132623</idno>
<date when="2002">2002</date>
<idno type="stanalyst">PASCAL 03-0132623 INIST</idno>
<idno type="RBID">Pascal:03-0132623</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000708</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000252</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema</title>
<author>
<name sortKey="Moseley, A" sort="Moseley, A" uniqKey="Moseley A" first="A." last="Moseley">A. Moseley</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
<author>
<name sortKey="Piller, N" sort="Piller, N" uniqKey="Piller N" first="N." last="Piller">N. Piller</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
<author>
<name sortKey="Carati, C" sort="Carati, C" uniqKey="Carati C" first="C." last="Carati">C. Carati</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
<country>Australie</country>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Lymphology</title>
<title level="j" type="abbreviated">Lymphology</title>
<idno type="ISSN">0024-7766</idno>
<imprint>
<date when="2002">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Lymphology</title>
<title level="j" type="abbreviated">Lymphology</title>
<idno type="ISSN">0024-7766</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Chronic</term>
<term>Diagnosis</term>
<term>Human</term>
<term>Impedancemetry</term>
<term>Leg</term>
<term>Lymphedema</term>
<term>Optoelectronic device</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Lymphoedème</term>
<term>Jambe</term>
<term>Chronique</term>
<term>Dispositif optoélectronique</term>
<term>Impédancemétrie</term>
<term>Diagnostic</term>
<term>Homme</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Secondary lymphedema of the legs is a common sequela of patients treated for cancer of the reproductive, gastrointestinal, urinary systems and melanoma. From a clinical and research perspective it is of utmost importance to use techniques that objectively quantify leg volume and fluid composition as an indicator of lymphedema severity and response to treatment. Two techniques often used in both the clinical and research setting are leg perometry and multi-frequency bioimpedance. Although both techniques have been extensively validated, this trial aimed to cross correlate both measurement techniques to ascertain whether each or both could be used reliably for measurement of leg lymphedema. These measurements were utilized throughout a clinical trial that assessed the effectiveness of a new home based treatment program in the form of the Sun Ancon Aerobic Exerciser®. This machine delivered both elevation and passive exercise to the legs, with participants using the machine over a three week period during which time their leg volumes were measured using both perometry and bioimpedance. The results demonstrated that leg volume measurements decreased using both perometry and bioimpedance. The reduction in body extracellular fluid as measured by bioimpedance correlated well with a reduction in leg volume as measured by perometry. Bioimpedance also recorded a reduction in weight, which was correlated with the reduction in leg volume as measured by perometry. This trial confirms that perometry and bioimpedance were both effective in independently showing a reduction in leg lymphedema using the Aerobic Exerciser therapy, and that both methods can be reliably used to measure and follow leg lymphedema.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0024-7766</s0>
</fA01>
<fA02 i1="01">
<s0>LYMPBN</s0>
</fA02>
<fA03 i2="1">
<s0>Lymphology</s0>
</fA03>
<fA05>
<s2>35</s2>
</fA05>
<fA06>
<s2>4</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>MOSELEY (A.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>PILLER (N.)</s1>
</fA11>
<fA11 i1="03" i2="1">
<s1>CARATI (C.)</s1>
</fA11>
<fA14 i1="01">
<s1>Lymphedema Assessment Clinic, Flinders Surgical Oncology Unit and Department of Public Health School of Medicine, Flinders Medical Centre, Bedford Park</s1>
<s2>Adelaide, South Australia</s2>
<s3>AUS</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
</fA14>
<fA20>
<s1>136-143</s1>
</fA20>
<fA21>
<s1>2002</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>14604</s2>
<s5>354000103813750010</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2003 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>26 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>03-0132623</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Lymphology</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Secondary lymphedema of the legs is a common sequela of patients treated for cancer of the reproductive, gastrointestinal, urinary systems and melanoma. From a clinical and research perspective it is of utmost importance to use techniques that objectively quantify leg volume and fluid composition as an indicator of lymphedema severity and response to treatment. Two techniques often used in both the clinical and research setting are leg perometry and multi-frequency bioimpedance. Although both techniques have been extensively validated, this trial aimed to cross correlate both measurement techniques to ascertain whether each or both could be used reliably for measurement of leg lymphedema. These measurements were utilized throughout a clinical trial that assessed the effectiveness of a new home based treatment program in the form of the Sun Ancon Aerobic Exerciser®. This machine delivered both elevation and passive exercise to the legs, with participants using the machine over a three week period during which time their leg volumes were measured using both perometry and bioimpedance. The results demonstrated that leg volume measurements decreased using both perometry and bioimpedance. The reduction in body extracellular fluid as measured by bioimpedance correlated well with a reduction in leg volume as measured by perometry. Bioimpedance also recorded a reduction in weight, which was correlated with the reduction in leg volume as measured by perometry. This trial confirms that perometry and bioimpedance were both effective in independently showing a reduction in leg lymphedema using the Aerobic Exerciser therapy, and that both methods can be reliably used to measure and follow leg lymphedema.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B12B04</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Lymphoedème</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Lymphedema</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Linfedema</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Jambe</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Leg</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Pierna</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Chronique</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Chronic</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Crónico</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Dispositif optoélectronique</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Optoelectronic device</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Dispositivo optoelectrónico</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Impédancemétrie</s0>
<s5>07</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Impedancemetry</s0>
<s5>07</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Impedanciometría</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Diagnostic</s0>
<s5>17</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Diagnosis</s0>
<s5>17</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Diagnóstico</s0>
<s5>17</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Homme</s0>
<s5>20</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Human</s0>
<s5>20</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Hombre</s0>
<s5>20</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Appareil circulatoire pathologie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Cardiovascular disease</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Aparato circulatorio patología</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="FRE">
<s0>Lymphatique pathologie</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="ENG">
<s0>Lymphatic vessel disease</s0>
<s5>38</s5>
</fC07>
<fC07 i1="02" i2="X" l="SPA">
<s0>Linfático patología</s0>
<s5>38</s5>
</fC07>
<fN21>
<s1>076</s1>
</fN21>
<fN82>
<s1>PSI</s1>
</fN82>
</pA>
</standard>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/PascalFrancis/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000252 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Curation/biblio.hfd -nk 000252 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    PascalFrancis
   |étape=   Curation
   |type=    RBID
   |clé=     Pascal:03-0132623
   |texte=   Combined opto-electronic perometry and bioimpedance to measure objectively the effectiveness of a new treatment intervention for chronic secondary lee lymphedema
}}

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024