Evaluation of lymph drainage using bioelectrical impedance of the body.
Identifieur interne : 004355 ( Ncbi/Merge ); précédent : 004354; suivant : 004356Evaluation of lymph drainage using bioelectrical impedance of the body.
Auteurs : J M P. De Godoy [Brésil] ; F M Valente ; L M Azoubel ; M F G. GodoySource :
- Phlebology [ 1758-1125 ] ; 2011.
Descripteurs français
- KwdFr :
- MESH :
- physiopathologie : Jambe, Lymphoedème.
- Composition corporelle, Femelle, Humains, Impédance électrique, Lymphe, Mâle.
English descriptors
- KwdEn :
- MESH :
- physiopathology : Leg, Lymphedema.
- Body Composition, Electric Impedance, Female, Humans, Lymph, Male.
Abstract
The aim of this study was to investigate the effects of manual and mechanical lymph drainage on the bioelectrical composition of body tissues of patients with lymphoedema of the lower limbs.
DOI: 10.1258/phleb.2010.010034
PubMed: 21576705
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 002627
- to stream PubMed, to step Curation: 002627
- to stream PubMed, to step Checkpoint: 002627
Links to Exploration step
pubmed:21576705Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Evaluation of lymph drainage using bioelectrical impedance of the body.</title>
<author><name sortKey="De Godoy, J M P" sort="De Godoy, J M P" uniqKey="De Godoy J" first="J M P" last="De Godoy">J M P. De Godoy</name>
<affiliation wicri:level="2"><nlm:affiliation>Rua Floriano Peixoto, São José do Rio Preto-SP, Brazil. godoyjmp@riopreto.com.br</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Rua Floriano Peixoto, São José do Rio Preto-SP</wicri:regionArea>
<placeName><region type="state">État de São Paulo</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Valente, F M" sort="Valente, F M" uniqKey="Valente F" first="F M" last="Valente">F M Valente</name>
</author>
<author><name sortKey="Azoubel, L M" sort="Azoubel, L M" uniqKey="Azoubel L" first="L M" last="Azoubel">L M Azoubel</name>
</author>
<author><name sortKey="Godoy, M F G" sort="Godoy, M F G" uniqKey="Godoy M" first="M F G" last="Godoy">M F G. Godoy</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2011">2011</date>
<idno type="RBID">pubmed:21576705</idno>
<idno type="pmid">21576705</idno>
<idno type="doi">10.1258/phleb.2010.010034</idno>
<idno type="wicri:Area/PubMed/Corpus">002627</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002627</idno>
<idno type="wicri:Area/PubMed/Curation">002627</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002627</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002627</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002627</idno>
<idno type="wicri:Area/Ncbi/Merge">004355</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Evaluation of lymph drainage using bioelectrical impedance of the body.</title>
<author><name sortKey="De Godoy, J M P" sort="De Godoy, J M P" uniqKey="De Godoy J" first="J M P" last="De Godoy">J M P. De Godoy</name>
<affiliation wicri:level="2"><nlm:affiliation>Rua Floriano Peixoto, São José do Rio Preto-SP, Brazil. godoyjmp@riopreto.com.br</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Rua Floriano Peixoto, São José do Rio Preto-SP</wicri:regionArea>
<placeName><region type="state">État de São Paulo</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Valente, F M" sort="Valente, F M" uniqKey="Valente F" first="F M" last="Valente">F M Valente</name>
</author>
<author><name sortKey="Azoubel, L M" sort="Azoubel, L M" uniqKey="Azoubel L" first="L M" last="Azoubel">L M Azoubel</name>
</author>
<author><name sortKey="Godoy, M F G" sort="Godoy, M F G" uniqKey="Godoy M" first="M F G" last="Godoy">M F G. Godoy</name>
</author>
</analytic>
<series><title level="j">Phlebology</title>
<idno type="eISSN">1758-1125</idno>
<imprint><date when="2011" type="published">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Body Composition</term>
<term>Electric Impedance</term>
<term>Female</term>
<term>Humans</term>
<term>Leg (physiopathology)</term>
<term>Lymph</term>
<term>Lymphedema (physiopathology)</term>
<term>Male</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Composition corporelle</term>
<term>Femelle</term>
<term>Humains</term>
<term>Impédance électrique</term>
<term>Jambe (physiopathologie)</term>
<term>Lymphe</term>
<term>Lymphoedème (physiopathologie)</term>
<term>Mâle</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr"><term>Jambe</term>
<term>Lymphoedème</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en"><term>Leg</term>
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Body Composition</term>
<term>Electric Impedance</term>
<term>Female</term>
<term>Humans</term>
<term>Lymph</term>
<term>Male</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Composition corporelle</term>
<term>Femelle</term>
<term>Humains</term>
<term>Impédance électrique</term>
<term>Lymphe</term>
<term>Mâle</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The aim of this study was to investigate the effects of manual and mechanical lymph drainage on the bioelectrical composition of body tissues of patients with lymphoedema of the lower limbs.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">21576705</PMID>
<DateCreated><Year>2011</Year>
<Month>10</Month>
<Day>10</Day>
</DateCreated>
<DateCompleted><Year>2012</Year>
<Month>01</Month>
<Day>26</Day>
</DateCompleted>
<DateRevised><Year>2016</Year>
<Month>10</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1758-1125</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>26</Volume>
<Issue>7</Issue>
<PubDate><Year>2011</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Phlebology</Title>
<ISOAbbreviation>Phlebology</ISOAbbreviation>
</Journal>
<ArticleTitle>Evaluation of lymph drainage using bioelectrical impedance of the body.</ArticleTitle>
<Pagination><MedlinePgn>298-300</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1258/phleb.2010.010034</ELocationID>
<Abstract><AbstractText Label="AIM" NlmCategory="OBJECTIVE">The aim of this study was to investigate the effects of manual and mechanical lymph drainage on the bioelectrical composition of body tissues of patients with lymphoedema of the lower limbs.</AbstractText>
<AbstractText Label="METHOD" NlmCategory="METHODS">Twenty-one patients with lymphoedema of one leg were evaluated using single frequency bioelectrical impedance with four electrodes (SF-BIA4) immediately before and after a combination of manual and mechanical lymph drainage. Statistical analysis used the two-tailed paired t-test with an alpha error of 5% being considered acceptable.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">On comparing the results before and after lymph drainage, statistically significant differences were identified for both lymphoedematous and apparently healthy legs, but there were no significant differences in the alterations caused by the treatment between the healthy and lymphoedematous limbs of the same patient.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">It was concluded that the association of manual and mechanical lymph drainage both modified the body composition as identified by bioelectrical impedance, and reduced the oedema.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>de Godoy</LastName>
<ForeName>J M P</ForeName>
<Initials>JM</Initials>
<AffiliationInfo><Affiliation>Rua Floriano Peixoto, São José do Rio Preto-SP, Brazil. godoyjmp@riopreto.com.br</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Valente</LastName>
<ForeName>F M</ForeName>
<Initials>FM</Initials>
</Author>
<Author ValidYN="Y"><LastName>Azoubel</LastName>
<ForeName>L M</ForeName>
<Initials>LM</Initials>
</Author>
<Author ValidYN="Y"><LastName>Godoy</LastName>
<ForeName>M F G</ForeName>
<Initials>MF</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016430">Clinical Trial</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2011</Year>
<Month>05</Month>
<Day>16</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>England</Country>
<MedlineTA>Phlebology</MedlineTA>
<NlmUniqueID>9012921</NlmUniqueID>
<ISSNLinking>0268-3555</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D001823" MajorTopicYN="Y">Body Composition</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017097" MajorTopicYN="N">Electric Impedance</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007866" MajorTopicYN="N">Leg</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008196" MajorTopicYN="Y">Lymph</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008209" MajorTopicYN="N">Lymphedema</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2011</Year>
<Month>5</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2011</Year>
<Month>5</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2012</Year>
<Month>1</Month>
<Day>27</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">21576705</ArticleId>
<ArticleId IdType="pii">phleb.2010.010034</ArticleId>
<ArticleId IdType="doi">10.1258/phleb.2010.010034</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations><list><country><li>Brésil</li>
</country>
<region><li>État de São Paulo</li>
</region>
</list>
<tree><noCountry><name sortKey="Azoubel, L M" sort="Azoubel, L M" uniqKey="Azoubel L" first="L M" last="Azoubel">L M Azoubel</name>
<name sortKey="Godoy, M F G" sort="Godoy, M F G" uniqKey="Godoy M" first="M F G" last="Godoy">M F G. Godoy</name>
<name sortKey="Valente, F M" sort="Valente, F M" uniqKey="Valente F" first="F M" last="Valente">F M Valente</name>
</noCountry>
<country name="Brésil"><region name="État de São Paulo"><name sortKey="De Godoy, J M P" sort="De Godoy, J M P" uniqKey="De Godoy J" first="J M P" last="De Godoy">J M P. De Godoy</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004355 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 004355 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Sante |area= LymphedemaV1 |flux= Ncbi |étape= Merge |type= RBID |clé= pubmed:21576705 |texte= Evaluation of lymph drainage using bioelectrical impedance of the body. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i -Sk "pubmed:21576705" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd \ | NlmPubMed2Wicri -a LymphedemaV1
This area was generated with Dilib version V0.6.31. |