The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema.
Identifieur interne : 00E541 ( Main/Merge ); précédent : 00E540; suivant : 00E542The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema.
Auteurs : F. Baulieu [France] ; J L Baulieu ; V. Secchi ; D. Casset ; J. Dabiens ; R. Itti ; J. BarsottiSource :
- Lymphology [ 0024-7766 ] ; 1990.
Descripteurs français
- KwdFr :
- MESH :
- imagerie diagnostique : Jambe, Lymphoedème.
- Adolescent, Adulte, Femelle, Humains, Scintigraphie, Sulfocolloïde de technétium (99mTc), Traitement d'image par ordinateur.
English descriptors
- KwdEn :
- MESH :
- chemical : Technetium Tc 99m Sulfur Colloid.
- diagnostic imaging : Leg, Lymphedema.
- Adolescent, Adult, Female, Humans, Image Processing, Computer-Assisted, Radionuclide Imaging.
Abstract
Condensed image processing (CIP), a computerized technique of scintiscans that generates a vertical distribution of activity as a function of time in a single image, was applied to isotopic lymphoscintigrams of four patients with leg lymphedema. By "condensing" information gained from multiple images into a single image, CIP better evaluates ascending progression of radiolabeled colloid in peripheral lymph and better localizes stagnant areas. In "high lymph flow failure," CIP also depicts radioactive "bursts" suggestive of increased lymphatic truncal contractility. This data processing method improves interpretation of dynamic scintiscan recordings and seems ideally suited for evaluation of peripheral lymph kinetics.
PubMed: 2352438
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 005D94
- to stream PubMed, to step Curation: 005D94
- to stream PubMed, to step Checkpoint: 005D94
- to stream Ncbi, to step Merge: 005736
- to stream Ncbi, to step Curation: 005736
- to stream Ncbi, to step Checkpoint: 005736
Links to Exploration step
pubmed:2352438Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema.</title>
<author><name sortKey="Baulieu, F" sort="Baulieu, F" uniqKey="Baulieu F" first="F" last="Baulieu">F. Baulieu</name>
<affiliation wicri:level="3"><nlm:affiliation>Department of Nuclear Medicine, Trousseau University Hospital, Tours, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Nuclear Medicine, Trousseau University Hospital, Tours</wicri:regionArea>
<placeName><region type="region">Centre-Val de Loire</region>
<region type="old region">Région Centre</region>
<settlement type="city">Tours</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Baulieu, J L" sort="Baulieu, J L" uniqKey="Baulieu J" first="J L" last="Baulieu">J L Baulieu</name>
</author>
<author><name sortKey="Secchi, V" sort="Secchi, V" uniqKey="Secchi V" first="V" last="Secchi">V. Secchi</name>
</author>
<author><name sortKey="Casset, D" sort="Casset, D" uniqKey="Casset D" first="D" last="Casset">D. Casset</name>
</author>
<author><name sortKey="Dabiens, J" sort="Dabiens, J" uniqKey="Dabiens J" first="J" last="Dabiens">J. Dabiens</name>
</author>
<author><name sortKey="Itti, R" sort="Itti, R" uniqKey="Itti R" first="R" last="Itti">R. Itti</name>
</author>
<author><name sortKey="Barsotti, J" sort="Barsotti, J" uniqKey="Barsotti J" first="J" last="Barsotti">J. Barsotti</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1990">1990</date>
<idno type="RBID">pubmed:2352438</idno>
<idno type="pmid">2352438</idno>
<idno type="wicri:Area/PubMed/Corpus">005D94</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">005D94</idno>
<idno type="wicri:Area/PubMed/Curation">005D94</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">005D94</idno>
<idno type="wicri:Area/PubMed/Checkpoint">005D94</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">005D94</idno>
<idno type="wicri:Area/Ncbi/Merge">005736</idno>
<idno type="wicri:Area/Ncbi/Curation">005736</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">005736</idno>
<idno type="wicri:doubleKey">0024-7766:1990:Baulieu F:the:potential:usefulness</idno>
<idno type="wicri:Area/Main/Merge">00E541</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema.</title>
<author><name sortKey="Baulieu, F" sort="Baulieu, F" uniqKey="Baulieu F" first="F" last="Baulieu">F. Baulieu</name>
<affiliation wicri:level="3"><nlm:affiliation>Department of Nuclear Medicine, Trousseau University Hospital, Tours, France.</nlm:affiliation>
<country xml:lang="fr">France</country>
<wicri:regionArea>Department of Nuclear Medicine, Trousseau University Hospital, Tours</wicri:regionArea>
<placeName><region type="region">Centre-Val de Loire</region>
<region type="old region">Région Centre</region>
<settlement type="city">Tours</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Baulieu, J L" sort="Baulieu, J L" uniqKey="Baulieu J" first="J L" last="Baulieu">J L Baulieu</name>
</author>
<author><name sortKey="Secchi, V" sort="Secchi, V" uniqKey="Secchi V" first="V" last="Secchi">V. Secchi</name>
</author>
<author><name sortKey="Casset, D" sort="Casset, D" uniqKey="Casset D" first="D" last="Casset">D. Casset</name>
</author>
<author><name sortKey="Dabiens, J" sort="Dabiens, J" uniqKey="Dabiens J" first="J" last="Dabiens">J. Dabiens</name>
</author>
<author><name sortKey="Itti, R" sort="Itti, R" uniqKey="Itti R" first="R" last="Itti">R. Itti</name>
</author>
<author><name sortKey="Barsotti, J" sort="Barsotti, J" uniqKey="Barsotti J" first="J" last="Barsotti">J. Barsotti</name>
</author>
</analytic>
<series><title level="j">Lymphology</title>
<idno type="ISSN">0024-7766</idno>
<imprint><date when="1990" type="published">1990</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Leg (diagnostic imaging)</term>
<term>Lymphedema (diagnostic imaging)</term>
<term>Radionuclide Imaging</term>
<term>Technetium Tc 99m Sulfur Colloid</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Adolescent</term>
<term>Adulte</term>
<term>Femelle</term>
<term>Humains</term>
<term>Jambe (imagerie diagnostique)</term>
<term>Lymphoedème (imagerie diagnostique)</term>
<term>Scintigraphie</term>
<term>Sulfocolloïde de technétium (99mTc)</term>
<term>Traitement d'image par ordinateur</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Technetium Tc 99m Sulfur Colloid</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Leg</term>
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Jambe</term>
<term>Lymphoedème</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adolescent</term>
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Radionuclide Imaging</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Adolescent</term>
<term>Adulte</term>
<term>Femelle</term>
<term>Humains</term>
<term>Scintigraphie</term>
<term>Sulfocolloïde de technétium (99mTc)</term>
<term>Traitement d'image par ordinateur</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Condensed image processing (CIP), a computerized technique of scintiscans that generates a vertical distribution of activity as a function of time in a single image, was applied to isotopic lymphoscintigrams of four patients with leg lymphedema. By "condensing" information gained from multiple images into a single image, CIP better evaluates ascending progression of radiolabeled colloid in peripheral lymph and better localizes stagnant areas. In "high lymph flow failure," CIP also depicts radioactive "bursts" suggestive of increased lymphatic truncal contractility. This data processing method improves interpretation of dynamic scintiscan recordings and seems ideally suited for evaluation of peripheral lymph kinetics.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00E541 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 00E541 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Sante |area= LymphedemaV1 |flux= Main |étape= Merge |type= RBID |clé= pubmed:2352438 |texte= The potential usefulness of condensed image processing of sequential lymphoscintigrams in patients with lymphedema. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:2352438" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a LymphedemaV1
This area was generated with Dilib version V0.6.31. |