Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index
Identifieur interne : 005C85 ( Main/Exploration ); précédent : 005C84; suivant : 005C86Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index
Auteurs : Harvey N. Mayrovitz [États-Unis]Source :
- Skin Research and Technology [ 0909-752X ] ; 2010-02.
Abstract
Background: Tissue dielectric constant (TDC) measured at 300 MHz via the coaxial line reflection method is useful to evaluate local tissue water (LTW) and its change. Because excitation field penetration depth depends on size and geometry of the coaxial probe in contact with the skin, TDC values reflect skin and subcutaneous fat to varying depths depending on the probe used. Because tissue changes that occur with age or body mass index (BMI) may affect tissue water content and its depth distribution, our goal was to use TDC measurements to characterize depth patterns of LTW in normal tissue and to investigate the possible impact of age and BMI.
Url:
DOI: 10.1111/j.1600-0846.2009.00398.x
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 004947
- to stream Istex, to step Curation: 004947
- to stream Istex, to step Checkpoint: 000A29
- to stream Main, to step Merge: 005D40
- to stream Main, to step Curation: 005C85
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index</title>
<author><name sortKey="Mayrovitz, Harvey N" sort="Mayrovitz, Harvey N" uniqKey="Mayrovitz H" first="Harvey N." last="Mayrovitz">Harvey N. Mayrovitz</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:9BE9EA3E69E6C8FD31479ED686CC35E2D340D990</idno>
<date when="2010" year="2010">2010</date>
<idno type="doi">10.1111/j.1600-0846.2009.00398.x</idno>
<idno type="url">https://api.istex.fr/document/9BE9EA3E69E6C8FD31479ED686CC35E2D340D990/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">004947</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">004947</idno>
<idno type="wicri:Area/Istex/Curation">004947</idno>
<idno type="wicri:Area/Istex/Checkpoint">000A29</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000A29</idno>
<idno type="wicri:doubleKey">0909-752X:2010:Mayrovitz H:local:tissue:water</idno>
<idno type="wicri:Area/Main/Merge">005D40</idno>
<idno type="wicri:Area/Main/Curation">005C85</idno>
<idno type="wicri:Area/Main/Exploration">005C85</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main">Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index</title>
<author><name sortKey="Mayrovitz, Harvey N" sort="Mayrovitz, Harvey N" uniqKey="Mayrovitz H" first="Harvey N." last="Mayrovitz">Harvey N. Mayrovitz</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>College of Medical Sciences, Nova Southeastern University, Ft. Lauderdale, FL</wicri:regionArea>
<placeName><region type="state">Floride</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j" type="main">Skin Research and Technology</title>
<title level="j" type="alt">SKIN RESEARCH TECHNOLOGY</title>
<idno type="ISSN">0909-752X</idno>
<idno type="eISSN">1600-0846</idno>
<imprint><biblScope unit="vol">16</biblScope>
<biblScope unit="issue">1</biblScope>
<biblScope unit="page" from="16">16</biblScope>
<biblScope unit="page" to="22">22</biblScope>
<biblScope unit="page-count">7</biblScope>
<publisher>Blackwell Publishing Ltd</publisher>
<pubPlace>Oxford, UK</pubPlace>
<date type="published" when="2010-02">2010-02</date>
</imprint>
<idno type="ISSN">0909-752X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0909-752X</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract">Background: Tissue dielectric constant (TDC) measured at 300 MHz via the coaxial line reflection method is useful to evaluate local tissue water (LTW) and its change. Because excitation field penetration depth depends on size and geometry of the coaxial probe in contact with the skin, TDC values reflect skin and subcutaneous fat to varying depths depending on the probe used. Because tissue changes that occur with age or body mass index (BMI) may affect tissue water content and its depth distribution, our goal was to use TDC measurements to characterize depth patterns of LTW in normal tissue and to investigate the possible impact of age and BMI.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Floride</li>
</region>
</list>
<tree><country name="États-Unis"><region name="Floride"><name sortKey="Mayrovitz, Harvey N" sort="Mayrovitz, Harvey N" uniqKey="Mayrovitz H" first="Harvey N." last="Mayrovitz">Harvey N. Mayrovitz</name>
</region>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005C85 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005C85 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Sante |area= LymphedemaV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:9BE9EA3E69E6C8FD31479ED686CC35E2D340D990 |texte= Local tissue water assessed by measuring forearm skin dielectric constant: dependence on measurement depth, age and body mass index }}
This area was generated with Dilib version V0.6.31. |