Serveur d'exploration sur le lymphœdème

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.

Identifieur interne : 005056 ( Main/Exploration ); précédent : 005055; suivant : 005057

Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.

Auteurs : Richelle Gaw [Australie] ; Robyn Box ; Bruce Cornish

Source :

RBID : pubmed:21688978

Descripteurs français

English descriptors

Abstract

Bioimpedance techniques provide a reliable method of assessing unilateral lymphedema in a clinical setting. Bioimpedance devices are traditionally used to assess body composition at a current frequency of 50 kHz. However, these devices are not transferable to the assessment of lymphedema, as the sensitivity of measuring the impedance of extracellular fluid is frequency dependent. It has previously been shown that the best frequency to detect extracellular fluid is 0 kHz (or DC). However, measurement at this frequency is not possible in practice due to the high skin impedance at DC, and an estimate is usually determined from low frequency measurements. This study investigated the efficacy of various low frequency ranges for the detection of lymphedema.

DOI: 10.1089/lrb.2010.0020
PubMed: 21688978


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.</title>
<author>
<name sortKey="Gaw, Richelle" sort="Gaw, Richelle" uniqKey="Gaw R" first="Richelle" last="Gaw">Richelle Gaw</name>
<affiliation wicri:level="1">
<nlm:affiliation>Queensland University of Technology, Brisbane, Australia.</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>Queensland University of Technology, Brisbane</wicri:regionArea>
<wicri:noRegion>Brisbane</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Box, Robyn" sort="Box, Robyn" uniqKey="Box R" first="Robyn" last="Box">Robyn Box</name>
</author>
<author>
<name sortKey="Cornish, Bruce" sort="Cornish, Bruce" uniqKey="Cornish B" first="Bruce" last="Cornish">Bruce Cornish</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2011">2011</date>
<idno type="RBID">pubmed:21688978</idno>
<idno type="pmid">21688978</idno>
<idno type="doi">10.1089/lrb.2010.0020</idno>
<idno type="wicri:Area/PubMed/Corpus">002573</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002573</idno>
<idno type="wicri:Area/PubMed/Curation">002573</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">002573</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002573</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">002573</idno>
<idno type="wicri:Area/Ncbi/Merge">004450</idno>
<idno type="wicri:Area/Ncbi/Curation">004450</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004450</idno>
<idno type="wicri:Area/Main/Merge">005094</idno>
<idno type="wicri:Area/Main/Curation">005056</idno>
<idno type="wicri:Area/Main/Exploration">005056</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.</title>
<author>
<name sortKey="Gaw, Richelle" sort="Gaw, Richelle" uniqKey="Gaw R" first="Richelle" last="Gaw">Richelle Gaw</name>
<affiliation wicri:level="1">
<nlm:affiliation>Queensland University of Technology, Brisbane, Australia.</nlm:affiliation>
<country xml:lang="fr">Australie</country>
<wicri:regionArea>Queensland University of Technology, Brisbane</wicri:regionArea>
<wicri:noRegion>Brisbane</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Box, Robyn" sort="Box, Robyn" uniqKey="Box R" first="Robyn" last="Box">Robyn Box</name>
</author>
<author>
<name sortKey="Cornish, Bruce" sort="Cornish, Bruce" uniqKey="Cornish B" first="Bruce" last="Cornish">Bruce Cornish</name>
</author>
</analytic>
<series>
<title level="j">Lymphatic research and biology</title>
<idno type="eISSN">1557-8585</idno>
<imprint>
<date when="2011" type="published">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Case-Control Studies</term>
<term>Electric Impedance</term>
<term>Humans</term>
<term>Lymphedema (physiopathology)</term>
<term>Middle Aged</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Humains</term>
<term>Impédance électrique</term>
<term>Lymphoedème (physiopathologie)</term>
<term>Études cas-témoins</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Lymphoedème</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Lymphedema</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Case-Control Studies</term>
<term>Electric Impedance</term>
<term>Humans</term>
<term>Middle Aged</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Humains</term>
<term>Impédance électrique</term>
<term>Études cas-témoins</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Bioimpedance techniques provide a reliable method of assessing unilateral lymphedema in a clinical setting. Bioimpedance devices are traditionally used to assess body composition at a current frequency of 50 kHz. However, these devices are not transferable to the assessment of lymphedema, as the sensitivity of measuring the impedance of extracellular fluid is frequency dependent. It has previously been shown that the best frequency to detect extracellular fluid is 0 kHz (or DC). However, measurement at this frequency is not possible in practice due to the high skin impedance at DC, and an estimate is usually determined from low frequency measurements. This study investigated the efficacy of various low frequency ranges for the detection of lymphedema.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Australie</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Box, Robyn" sort="Box, Robyn" uniqKey="Box R" first="Robyn" last="Box">Robyn Box</name>
<name sortKey="Cornish, Bruce" sort="Cornish, Bruce" uniqKey="Cornish B" first="Bruce" last="Cornish">Bruce Cornish</name>
</noCountry>
<country name="Australie">
<noRegion>
<name sortKey="Gaw, Richelle" sort="Gaw, Richelle" uniqKey="Gaw R" first="Richelle" last="Gaw">Richelle Gaw</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005056 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005056 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:21688978
   |texte=   Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:21688978" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024