Reliability of a Scoring System for Qualitative Evaluation of Lymphoscintigraphy of the Lower Extremities.

Identifieur interne : 000225 ( Main/Exploration ); précédent : 000224; suivant : 000226

Reliability of a Scoring System for Qualitative Evaluation of Lymphoscintigraphy of the Lower Extremities.

Auteurs : Mojgan Ebrahim ; Irina Savitcheva ; Rimma Axelsson [Suède]

Source :

RBID : pubmed:28473462

Abstract

Lymphoscintigraphy is an imaging technique to diagnose and characterize the severity of edema in the upper and lower extremities. In lymphoscintigraphy, a scoring system can increase the ability to differentiate between diagnoses, but the use of any scoring system requires sufficient reliability. Our aim was to determine the inter- and intraobserver reliability of a proposed scoring system for visual interpretation of lymphoscintigrams of the lower extremities. Methods: The lymphoscintigrams of 81 persons were randomly selected from our database for retrospective evaluation. Two nuclear medicine physicians scored these scans according to the 8 criteria of a proposed scoring system for visual interpretation of lymphoscintigrams of the lower extremities. Each scan was scored twice 3 mo apart. The total score was the sum of the scores for all criteria, with a potential range of 0 (normal lymphatic drainage) to 58 (severe lymphatic impairment). The intra- and interobserver reliability of the scoring system was determined using the Wilcoxon signed-rank test, percentage of agreement, weighted κ, and intraclass correlation coefficient with 95% confidence interval. In addition, for 7 categories, differences in total scores between and within observers were determined. Results: We found some insignificant differences between observers. Percentage agreement was high or very high, at 82.7%-99.4% between observers and 84.6%-99.4% within observers. For each criterion of the scoring system, the κ-correlations showed moderate to very good inter- or intraobserver reliability. The total scores for all criteria had good inter- and intraobserver reliability. Regarding the interobserver comparison, 66% and 64% of the difference in total scores were within ±1 scale point (-1, +1), and regarding the intraobserver comparison, 68% and 72% of the difference in total scores were within ±1 scale point. Conclusion: The proposed scoring system is a reliable tool for visual qualitative evaluation of lymph transport problems in patients with lymphedema of the lower extremities.

DOI: 10.2967/jnmt.116.185710
PubMed: 28473462


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Reliability of a Scoring System for Qualitative Evaluation of Lymphoscintigraphy of the Lower Extremities.</title>
<author>
<name sortKey="Ebrahim, Mojgan" sort="Ebrahim, Mojgan" uniqKey="Ebrahim M" first="Mojgan" last="Ebrahim">Mojgan Ebrahim</name>
<affiliation>
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and.</nlm:affiliation>
<wicri:noCountry code="subField">Sweden; and</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Savitcheva, Irina" sort="Savitcheva, Irina" uniqKey="Savitcheva I" first="Irina" last="Savitcheva">Irina Savitcheva</name>
<affiliation>
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and.</nlm:affiliation>
<wicri:noCountry code="subField">Sweden; and</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Axelsson, Rimma" sort="Axelsson, Rimma" uniqKey="Axelsson R" first="Rimma" last="Axelsson">Rimma Axelsson</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and rimma.axelsson@ki.se.</nlm:affiliation>
<country wicri:rule="url">Suède</country>
<wicri:regionArea>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna</wicri:regionArea>
<wicri:noRegion>Solna</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2017">2017</date>
<idno type="RBID">pubmed:28473462</idno>
<idno type="pmid">28473462</idno>
<idno type="doi">10.2967/jnmt.116.185710</idno>
<idno type="wicri:Area/PubMed/Corpus">000223</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000223</idno>
<idno type="wicri:Area/PubMed/Curation">000223</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000223</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000223</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000223</idno>
<idno type="wicri:Area/Ncbi/Merge">009041</idno>
<idno type="wicri:Area/Ncbi/Curation">009041</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">009041</idno>
<idno type="wicri:Area/Main/Merge">000225</idno>
<idno type="wicri:Area/Main/Curation">000225</idno>
<idno type="wicri:Area/Main/Exploration">000225</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Reliability of a Scoring System for Qualitative Evaluation of Lymphoscintigraphy of the Lower Extremities.</title>
<author>
<name sortKey="Ebrahim, Mojgan" sort="Ebrahim, Mojgan" uniqKey="Ebrahim M" first="Mojgan" last="Ebrahim">Mojgan Ebrahim</name>
<affiliation>
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and.</nlm:affiliation>
<wicri:noCountry code="subField">Sweden; and</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Savitcheva, Irina" sort="Savitcheva, Irina" uniqKey="Savitcheva I" first="Irina" last="Savitcheva">Irina Savitcheva</name>
<affiliation>
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and.</nlm:affiliation>
<wicri:noCountry code="subField">Sweden; and</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Axelsson, Rimma" sort="Axelsson, Rimma" uniqKey="Axelsson R" first="Rimma" last="Axelsson">Rimma Axelsson</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna, Sweden; and rimma.axelsson@ki.se.</nlm:affiliation>
<country wicri:rule="url">Suède</country>
<wicri:regionArea>Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Solna</wicri:regionArea>
<wicri:noRegion>Solna</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Journal of nuclear medicine technology</title>
<idno type="eISSN">1535-5675</idno>
<imprint>
<date when="2017" type="published">2017</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Lymphoscintigraphy is an imaging technique to diagnose and characterize the severity of edema in the upper and lower extremities. In lymphoscintigraphy, a scoring system can increase the ability to differentiate between diagnoses, but the use of any scoring system requires sufficient reliability. Our aim was to determine the inter- and intraobserver reliability of a proposed scoring system for visual interpretation of lymphoscintigrams of the lower extremities. Methods: The lymphoscintigrams of 81 persons were randomly selected from our database for retrospective evaluation. Two nuclear medicine physicians scored these scans according to the 8 criteria of a proposed scoring system for visual interpretation of lymphoscintigrams of the lower extremities. Each scan was scored twice 3 mo apart. The total score was the sum of the scores for all criteria, with a potential range of 0 (normal lymphatic drainage) to 58 (severe lymphatic impairment). The intra- and interobserver reliability of the scoring system was determined using the Wilcoxon signed-rank test, percentage of agreement, weighted κ, and intraclass correlation coefficient with 95% confidence interval. In addition, for 7 categories, differences in total scores between and within observers were determined. Results: We found some insignificant differences between observers. Percentage agreement was high or very high, at 82.7%-99.4% between observers and 84.6%-99.4% within observers. For each criterion of the scoring system, the κ-correlations showed moderate to very good inter- or intraobserver reliability. The total scores for all criteria had good inter- and intraobserver reliability. Regarding the interobserver comparison, 66% and 64% of the difference in total scores were within ±1 scale point (-1, +1), and regarding the intraobserver comparison, 68% and 72% of the difference in total scores were within ±1 scale point. Conclusion: The proposed scoring system is a reliable tool for visual qualitative evaluation of lymph transport problems in patients with lymphedema of the lower extremities.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Suède</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Ebrahim, Mojgan" sort="Ebrahim, Mojgan" uniqKey="Ebrahim M" first="Mojgan" last="Ebrahim">Mojgan Ebrahim</name>
<name sortKey="Savitcheva, Irina" sort="Savitcheva, Irina" uniqKey="Savitcheva I" first="Irina" last="Savitcheva">Irina Savitcheva</name>
</noCountry>
<country name="Suède">
<noRegion>
<name sortKey="Axelsson, Rimma" sort="Axelsson, Rimma" uniqKey="Axelsson R" first="Rimma" last="Axelsson">Rimma Axelsson</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/LymphedemaV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000225 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000225 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    LymphedemaV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:28473462
   |texte=   Reliability of a Scoring System for Qualitative Evaluation of Lymphoscintigraphy of the Lower Extremities.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:28473462" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a LymphedemaV1 

Wicri

This area was generated with Dilib version V0.6.31.
Data generation: Sat Nov 4 17:40:35 2017. Site generation: Tue Feb 13 16:42:16 2024