[Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants].
Identifieur interne : 004C28 ( PubMed/Curation ); précédent : 004C27; suivant : 004C29[Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants].
Auteurs : I. SewerinSource :
- Tandlaegebladet [ 0039-9353 ] ; 1989.
Descripteurs français
- KwdFr :
- MESH :
- imagerie diagnostique : Bouche édentée.
- Dose de radiation, Humains, Pose d'implant dentaire endo-osseux, Radiographie.
English descriptors
- KwdEn :
- MESH :
- diagnostic imaging : Mouth, Edentulous.
- Dental Implantation, Endosseous, Humans, Radiation Dosage, Radiography.
Abstract
A survey was made of the total number of extraoral and intraoral exposures performed during the preoperative, intermediate and control phases in treatment of patients with osseointegrated implants ad modum Brånemark according to the routine procedures used at the Department of Radiology, Royal Dental College, Copenhagen. Dose values from literature were used for calculation of total effective dose equivalent. The sum of examinations comprised 16 extraoral and 231 intraoral films for a patient treated with 6 maxillary and 6 mandibular implants. The total dose over a 7-year-period amounted to approximately 1.7 mSv (0.25 mSv per year). Considering that the natural radiation in Denmark results in an annual dose of 3 mSv per inhabitant and many medical radiographic examinations result in effective dose equivalents of 3-6 mSv, the dose following the treatment with implants appear to be of a moderate magnitude. The increased scattering due to the metallic implants does not seem of deleterious significance.
PubMed: 2635429
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :004C28
Links to Exploration step
pubmed:2635429Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants].</title>
<author><name sortKey="Sewerin, I" sort="Sewerin, I" uniqKey="Sewerin I" first="I" last="Sewerin">I. Sewerin</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1989">1989</date>
<idno type="RBID">pubmed:2635429</idno>
<idno type="pmid">2635429</idno>
<idno type="wicri:Area/PubMed/Corpus">004C28</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004C28</idno>
<idno type="wicri:Area/PubMed/Curation">004C28</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">004C28</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants].</title>
<author><name sortKey="Sewerin, I" sort="Sewerin, I" uniqKey="Sewerin I" first="I" last="Sewerin">I. Sewerin</name>
</author>
</analytic>
<series><title level="j">Tandlaegebladet</title>
<idno type="ISSN">0039-9353</idno>
<imprint><date when="1989" type="published">1989</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>Mouth, Edentulous (diagnostic imaging)</term>
<term>Radiation Dosage</term>
<term>Radiography</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Bouche édentée (imagerie diagnostique)</term>
<term>Dose de radiation</term>
<term>Humains</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Mouth, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Bouche édentée</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>Radiation Dosage</term>
<term>Radiography</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Dose de radiation</term>
<term>Humains</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A survey was made of the total number of extraoral and intraoral exposures performed during the preoperative, intermediate and control phases in treatment of patients with osseointegrated implants ad modum Brånemark according to the routine procedures used at the Department of Radiology, Royal Dental College, Copenhagen. Dose values from literature were used for calculation of total effective dose equivalent. The sum of examinations comprised 16 extraoral and 231 intraoral films for a patient treated with 6 maxillary and 6 mandibular implants. The total dose over a 7-year-period amounted to approximately 1.7 mSv (0.25 mSv per year). Considering that the natural radiation in Denmark results in an annual dose of 3 mSv per inhabitant and many medical radiographic examinations result in effective dose equivalents of 3-6 mSv, the dose following the treatment with implants appear to be of a moderate magnitude. The increased scattering due to the metallic implants does not seem of deleterious significance.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">2635429</PMID>
<DateCompleted><Year>1990</Year>
<Month>06</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised><Year>2016</Year>
<Month>11</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0039-9353</ISSN>
<JournalIssue CitedMedium="Print"><Volume>93</Volume>
<Issue>17</Issue>
<PubDate><Year>1989</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Tandlaegebladet</Title>
<ISOAbbreviation>Tandlaegebladet</ISOAbbreviation>
</Journal>
<ArticleTitle>[Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants].</ArticleTitle>
<Pagination><MedlinePgn>657-60</MedlinePgn>
</Pagination>
<Abstract><AbstractText>A survey was made of the total number of extraoral and intraoral exposures performed during the preoperative, intermediate and control phases in treatment of patients with osseointegrated implants ad modum Brånemark according to the routine procedures used at the Department of Radiology, Royal Dental College, Copenhagen. Dose values from literature were used for calculation of total effective dose equivalent. The sum of examinations comprised 16 extraoral and 231 intraoral films for a patient treated with 6 maxillary and 6 mandibular implants. The total dose over a 7-year-period amounted to approximately 1.7 mSv (0.25 mSv per year). Considering that the natural radiation in Denmark results in an annual dose of 3 mSv per inhabitant and many medical radiographic examinations result in effective dose equivalents of 3-6 mSv, the dose following the treatment with implants appear to be of a moderate magnitude. The increased scattering due to the metallic implants does not seem of deleterious significance.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Sewerin</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
</Author>
</AuthorList>
<Language>dan</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<VernacularTitle>Strålebelastning ved røntgenundersøgelser i forbindelse med behandling af tandløse kaeber med osseointegrerede implantater.</VernacularTitle>
</Article>
<MedlineJournalInfo><Country>Denmark</Country>
<MedlineTA>Tandlaegebladet</MedlineTA>
<NlmUniqueID>0404553</NlmUniqueID>
<ISSNLinking>0039-9353</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D003758" MajorTopicYN="Y">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D009066" MajorTopicYN="N">Mouth, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011829" MajorTopicYN="Y">Radiation Dosage</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1989</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">2635429</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004C28 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 004C28 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:2635429 |texte= [Effective dose equivalent following radiographic examination of edentulous patient treated by osseointegrated implants]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:2635429" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |