In vitro investigation of various attachments for overdentures on osseointegrated implants.

Identifieur interne : 004212 ( PubMed/Curation ); précédent : 004211; suivant : 004213

In vitro investigation of various attachments for overdentures on osseointegrated implants.

Auteurs : C. Besimo [Suisse] ; B. Kempf

Source :

RBID : pubmed:7490669

Descripteurs français

English descriptors

Abstract

Primary splinting of fixtures with bar attachments has proved to be clinically effective for overdentures on osseointegrated implants in the edentulous mandible. However, in vitro investigations indicate that a more favourable force transfer to the individual fixtures can be attained by secondary splinting of four implants with conical double crowns. This observation could be confirmed in the present study by measurement of implant deflection in a model of the mandible by means of interferometric optical holography. Telescope crowns with conical interface brought about functionally more even movement characteristics of the implants compared to rigid or jointed bar attachments. Moreover, the conical double crowns always ensured a stable position of the denture in contrast to jointed attachments. These results underscore the need to test conical double crowns clinically as anchors for overdentures on osseointegrated implants.

PubMed: 7490669

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:7490669

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">In vitro investigation of various attachments for overdentures on osseointegrated implants.</title>
<author>
<name sortKey="Besimo, C" sort="Besimo, C" uniqKey="Besimo C" first="C" last="Besimo">C. Besimo</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Prosthodontics, School of Dentistry, University of Basle, Switzerland.</nlm:affiliation>
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Prosthodontics, School of Dentistry, University of Basle</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kempf, B" sort="Kempf, B" uniqKey="Kempf B" first="B" last="Kempf">B. Kempf</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:7490669</idno>
<idno type="pmid">7490669</idno>
<idno type="wicri:Area/PubMed/Corpus">004212</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004212</idno>
<idno type="wicri:Area/PubMed/Curation">004212</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">004212</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">In vitro investigation of various attachments for overdentures on osseointegrated implants.</title>
<author>
<name sortKey="Besimo, C" sort="Besimo, C" uniqKey="Besimo C" first="C" last="Besimo">C. Besimo</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Prosthodontics, School of Dentistry, University of Basle, Switzerland.</nlm:affiliation>
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>Department of Prosthodontics, School of Dentistry, University of Basle</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kempf, B" sort="Kempf, B" uniqKey="Kempf B" first="B" last="Kempf">B. Kempf</name>
</author>
</analytic>
<series>
<title level="j">Journal of oral rehabilitation</title>
<idno type="ISSN">0305-182X</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Crowns</term>
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Denture Precision Attachment</term>
<term>Denture, Overlay</term>
<term>Holography</term>
<term>Humans</term>
<term>Interferometry</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Models, Anatomic</term>
<term>Osseointegration</term>
<term>Stress, Mechanical</term>
<term>Surface Properties</term>
<term>Titanium</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Attachement de précision</term>
<term>Conception de prothèse dentaire</term>
<term>Contrainte mécanique</term>
<term>Couronnes</term>
<term>Holographie</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Interférométrie</term>
<term>Mandibule</term>
<term>Modèles anatomiques</term>
<term>Mâchoire édentée</term>
<term>Ostéo-intégration</term>
<term>Overdenture</term>
<term>Piliers dentaires</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Propriétés de surface</term>
<term>Titane</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Crowns</term>
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Denture Precision Attachment</term>
<term>Denture, Overlay</term>
<term>Holography</term>
<term>Humans</term>
<term>Interferometry</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Models, Anatomic</term>
<term>Osseointegration</term>
<term>Stress, Mechanical</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Attachement de précision</term>
<term>Conception de prothèse dentaire</term>
<term>Contrainte mécanique</term>
<term>Couronnes</term>
<term>Holographie</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Interférométrie</term>
<term>Mandibule</term>
<term>Modèles anatomiques</term>
<term>Mâchoire édentée</term>
<term>Ostéo-intégration</term>
<term>Overdenture</term>
<term>Piliers dentaires</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Propriétés de surface</term>
<term>Titane</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Primary splinting of fixtures with bar attachments has proved to be clinically effective for overdentures on osseointegrated implants in the edentulous mandible. However, in vitro investigations indicate that a more favourable force transfer to the individual fixtures can be attained by secondary splinting of four implants with conical double crowns. This observation could be confirmed in the present study by measurement of implant deflection in a model of the mandible by means of interferometric optical holography. Telescope crowns with conical interface brought about functionally more even movement characteristics of the implants compared to rigid or jointed bar attachments. Moreover, the conical double crowns always ensured a stable position of the denture in contrast to jointed attachments. These results underscore the need to test conical double crowns clinically as anchors for overdentures on osseointegrated implants.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">7490669</PMID>
<DateCompleted>
<Year>1996</Year>
<Month>01</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0305-182X</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>22</Volume>
<Issue>9</Issue>
<PubDate>
<Year>1995</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Journal of oral rehabilitation</Title>
<ISOAbbreviation>J Oral Rehabil</ISOAbbreviation>
</Journal>
<ArticleTitle>In vitro investigation of various attachments for overdentures on osseointegrated implants.</ArticleTitle>
<Pagination>
<MedlinePgn>691-8</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Primary splinting of fixtures with bar attachments has proved to be clinically effective for overdentures on osseointegrated implants in the edentulous mandible. However, in vitro investigations indicate that a more favourable force transfer to the individual fixtures can be attained by secondary splinting of four implants with conical double crowns. This observation could be confirmed in the present study by measurement of implant deflection in a model of the mandible by means of interferometric optical holography. Telescope crowns with conical interface brought about functionally more even movement characteristics of the implants compared to rigid or jointed bar attachments. Moreover, the conical double crowns always ensured a stable position of the denture in contrast to jointed attachments. These results underscore the need to test conical double crowns clinically as anchors for overdentures on osseointegrated implants.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Besimo</LastName>
<ForeName>C</ForeName>
<Initials>C</Initials>
<AffiliationInfo>
<Affiliation>Department of Prosthodontics, School of Dentistry, University of Basle, Switzerland.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Kempf</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>J Oral Rehabil</MedlineTA>
<NlmUniqueID>0433604</NlmUniqueID>
<ISSNLinking>0305-182X</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D003442" MajorTopicYN="N">Crowns</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="Y">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003834" MajorTopicYN="Y">Denture Precision Attachment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006696" MajorTopicYN="N">Holography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007368" MajorTopicYN="N">Interferometry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008953" MajorTopicYN="N">Models, Anatomic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016348" MajorTopicYN="Y">Osseointegration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013314" MajorTopicYN="N">Stress, Mechanical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">7490669</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004212 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 004212 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:7490669
   |texte=   In vitro investigation of various attachments for overdentures on osseointegrated implants.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:7490669" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022