Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography.
Identifieur interne : 003168 ( PubMed/Curation ); précédent : 003167; suivant : 003169Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography.
Auteurs : K H Thunthy [États-Unis]Source :
- Dento maxillo facial radiology [ 0250-832X ] ; 2002.
Descripteurs français
- KwdFr :
- Dose de radiation, Filtration, Humains, Mandibule (imagerie diagnostique), Mâchoire édentée (imagerie diagnostique), Planification des soins du patient, Pose d'implant dentaire endo-osseux, Radiographie numérisée dentaire, Rayons X, Reproductibilité des résultats, Technologie radiologique, Tomodensitométrie.
- MESH :
English descriptors
- KwdEn :
- MESH :
Abstract
In dental implant tomography, a clinician typically makes several tomograms of cross-sectional and sagittal slices at and near the intended implantation site. The slice with the sharpest image of the metal marker is deemed to be the correct implantation site; the other slices with blurred images of the marker are those made either mesially or distally to the marker. However, if the images were over- or underexposed, the marker will be blurred on all the slices and a dentist may be wrongly accused of having placed a dental implant at an improper site with possible medico-legal ramifications.
DOI: 10.1038/sj.dmfr.4600699
PubMed: 12087446
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :003168
Links to Exploration step
pubmed:12087446Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography.</title>
<author><name sortKey="Thunthy, K H" sort="Thunthy, K H" uniqKey="Thunthy K" first="K H" last="Thunthy">K H Thunthy</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Oral Diagnosis, Medicine and Radiology, Louisiana State University School of Dentistry, New Orleans, Louisiana 70119-2799, USA. kthunt@lsuhsc.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Oral Diagnosis, Medicine and Radiology, Louisiana State University School of Dentistry, New Orleans, Louisiana 70119-2799</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2002">2002</date>
<idno type="RBID">pubmed:12087446</idno>
<idno type="pmid">12087446</idno>
<idno type="doi">10.1038/sj.dmfr.4600699</idno>
<idno type="wicri:Area/PubMed/Corpus">003168</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003168</idno>
<idno type="wicri:Area/PubMed/Curation">003168</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">003168</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography.</title>
<author><name sortKey="Thunthy, K H" sort="Thunthy, K H" uniqKey="Thunthy K" first="K H" last="Thunthy">K H Thunthy</name>
<affiliation wicri:level="1"><nlm:affiliation>Department of Oral Diagnosis, Medicine and Radiology, Louisiana State University School of Dentistry, New Orleans, Louisiana 70119-2799, USA. kthunt@lsuhsc.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Oral Diagnosis, Medicine and Radiology, Louisiana State University School of Dentistry, New Orleans, Louisiana 70119-2799</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series><title level="j">Dento maxillo facial radiology</title>
<idno type="ISSN">0250-832X</idno>
<imprint><date when="2002" type="published">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Filtration</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Patient Care Planning</term>
<term>Radiation Dosage</term>
<term>Radiography, Dental, Digital</term>
<term>Reproducibility of Results</term>
<term>Technology, Radiologic</term>
<term>Tomography, X-Ray Computed</term>
<term>X-Rays</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr"><term>Dose de radiation</term>
<term>Filtration</term>
<term>Humains</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Planification des soins du patient</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie numérisée dentaire</term>
<term>Rayons X</term>
<term>Reproductibilité des résultats</term>
<term>Technologie radiologique</term>
<term>Tomodensitométrie</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en"><term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr"><term>Mandibule</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Filtration</term>
<term>Humans</term>
<term>Patient Care Planning</term>
<term>Radiation Dosage</term>
<term>Radiography, Dental, Digital</term>
<term>Reproducibility of Results</term>
<term>Technology, Radiologic</term>
<term>Tomography, X-Ray Computed</term>
<term>X-Rays</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr"><term>Dose de radiation</term>
<term>Filtration</term>
<term>Humains</term>
<term>Planification des soins du patient</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie numérisée dentaire</term>
<term>Rayons X</term>
<term>Reproductibilité des résultats</term>
<term>Technologie radiologique</term>
<term>Tomodensitométrie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">In dental implant tomography, a clinician typically makes several tomograms of cross-sectional and sagittal slices at and near the intended implantation site. The slice with the sharpest image of the metal marker is deemed to be the correct implantation site; the other slices with blurred images of the marker are those made either mesially or distally to the marker. However, if the images were over- or underexposed, the marker will be blurred on all the slices and a dentist may be wrongly accused of having placed a dental implant at an improper site with possible medico-legal ramifications.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">12087446</PMID>
<DateCompleted><Year>2002</Year>
<Month>11</Month>
<Day>18</Day>
</DateCompleted>
<DateRevised><Year>2016</Year>
<Month>11</Month>
<Day>24</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0250-832X</ISSN>
<JournalIssue CitedMedium="Print"><Volume>31</Volume>
<Issue>4</Issue>
<PubDate><Year>2002</Year>
<Month>Jul</Month>
</PubDate>
</JournalIssue>
<Title>Dento maxillo facial radiology</Title>
<ISOAbbreviation>Dentomaxillofac Radiol</ISOAbbreviation>
</Journal>
<ArticleTitle>Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography.</ArticleTitle>
<Pagination><MedlinePgn>278-80</MedlinePgn>
</Pagination>
<Abstract><AbstractText>In dental implant tomography, a clinician typically makes several tomograms of cross-sectional and sagittal slices at and near the intended implantation site. The slice with the sharpest image of the metal marker is deemed to be the correct implantation site; the other slices with blurred images of the marker are those made either mesially or distally to the marker. However, if the images were over- or underexposed, the marker will be blurred on all the slices and a dentist may be wrongly accused of having placed a dental implant at an improper site with possible medico-legal ramifications.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Thunthy</LastName>
<ForeName>K H</ForeName>
<Initials>KH</Initials>
<AffiliationInfo><Affiliation>Department of Oral Diagnosis, Medicine and Radiology, Louisiana State University School of Dentistry, New Orleans, Louisiana 70119-2799, USA. kthunt@lsuhsc.edu</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>England</Country>
<MedlineTA>Dentomaxillofac Radiol</MedlineTA>
<NlmUniqueID>7609576</NlmUniqueID>
<ISSNLinking>0250-832X</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D003758" MajorTopicYN="Y">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005374" MajorTopicYN="N">Filtration</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011829" MajorTopicYN="N">Radiation Dosage</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019252" MajorTopicYN="Y">Radiography, Dental, Digital</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D013679" MajorTopicYN="N">Technology, Radiologic</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014057" MajorTopicYN="N">Tomography, X-Ray Computed</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014965" MajorTopicYN="N">X-Rays</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2001</Year>
<Month>06</Month>
<Day>27</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2001</Year>
<Month>10</Month>
<Day>05</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2002</Year>
<Month>6</Month>
<Day>28</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2002</Year>
<Month>11</Month>
<Day>26</Day>
<Hour>4</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2002</Year>
<Month>6</Month>
<Day>28</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12087446</ArticleId>
<ArticleId IdType="doi">10.1038/sj.dmfr.4600699</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003168 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 003168 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Curation |type= RBID |clé= pubmed:12087446 |texte= Effect of over- and underexposure on the sharpness of the image of a marker in computer-assisted dental implant tomography. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i -Sk "pubmed:12087446" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |