Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Potential damage to bone-implant interface when measuring initial implant stability.

Identifieur interne : 001B75 ( PubMed/Curation ); précédent : 001B74; suivant : 001B76

Potential damage to bone-implant interface when measuring initial implant stability.

Auteurs : Wook-Jin Seong [États-Unis] ; Heather J. Conrad ; James E. Hinrichs

Source :

RBID : pubmed:19905957

Descripteurs français

English descriptors

Abstract

An electronically controlled mechanical tapping device (MTD) to measure implant stability has been studied extensively for its ability to measure initial stability at the time of surgical placement and predict an implant's survival prognosis, with few reported complications.

DOI: 10.1902/jop.2009.090169
PubMed: 19905957

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:19905957

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Potential damage to bone-implant interface when measuring initial implant stability.</title>
<author>
<name sortKey="Seong, Wook Jin" sort="Seong, Wook Jin" uniqKey="Seong W" first="Wook-Jin" last="Seong">Wook-Jin Seong</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA. seong001@umn.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Conrad, Heather J" sort="Conrad, Heather J" uniqKey="Conrad H" first="Heather J" last="Conrad">Heather J. Conrad</name>
</author>
<author>
<name sortKey="Hinrichs, James E" sort="Hinrichs, James E" uniqKey="Hinrichs J" first="James E" last="Hinrichs">James E. Hinrichs</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="RBID">pubmed:19905957</idno>
<idno type="pmid">19905957</idno>
<idno type="doi">10.1902/jop.2009.090169</idno>
<idno type="wicri:Area/PubMed/Corpus">001B75</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001B75</idno>
<idno type="wicri:Area/PubMed/Curation">001B75</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">001B75</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Potential damage to bone-implant interface when measuring initial implant stability.</title>
<author>
<name sortKey="Seong, Wook Jin" sort="Seong, Wook Jin" uniqKey="Seong W" first="Wook-Jin" last="Seong">Wook-Jin Seong</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA. seong001@umn.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Conrad, Heather J" sort="Conrad, Heather J" uniqKey="Conrad H" first="Heather J" last="Conrad">Heather J. Conrad</name>
</author>
<author>
<name sortKey="Hinrichs, James E" sort="Hinrichs, James E" uniqKey="Hinrichs J" first="James E" last="Hinrichs">James E. Hinrichs</name>
</author>
</analytic>
<series>
<title level="j">Journal of periodontology</title>
<idno type="eISSN">1943-3670</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged, 80 and over</term>
<term>Bone Density</term>
<term>Cadaver</term>
<term>Dental Arch (pathology)</term>
<term>Dental Arch (surgery)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Retention</term>
<term>Humans</term>
<term>Jaw, Edentulous (pathology)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Male</term>
<term>Mandible (pathology)</term>
<term>Mandible (surgery)</term>
<term>Mandibular Injuries (etiology)</term>
<term>Maxilla (pathology)</term>
<term>Maxilla (surgery)</term>
<term>Maxillary Fractures (etiology)</term>
<term>Surface Properties</term>
<term>Vibration</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Arcade dentaire ()</term>
<term>Arcade dentaire (anatomopathologie)</term>
<term>Cadavre</term>
<term>Densité osseuse</term>
<term>Fractures du maxillaire (étiologie)</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule ()</term>
<term>Mandibule (anatomopathologie)</term>
<term>Maxillaire ()</term>
<term>Maxillaire (anatomopathologie)</term>
<term>Mâchoire édentée ()</term>
<term>Mâchoire édentée (anatomopathologie)</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Propriétés de surface</term>
<term>Rétention de prothèse dentaire</term>
<term>Sujet âgé de 80 ans ou plus</term>
<term>Traumatismes mandibulaires (étiologie)</term>
<term>Vibration</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomopathologie" xml:lang="fr">
<term>Arcade dentaire</term>
<term>Mandibule</term>
<term>Maxillaire</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Mandibular Injuries</term>
<term>Maxillary Fractures</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Dental Arch</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Dental Arch</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" qualifier="étiologie" xml:lang="fr">
<term>Fractures du maxillaire</term>
<term>Traumatismes mandibulaires</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged, 80 and over</term>
<term>Bone Density</term>
<term>Cadaver</term>
<term>Dental Prosthesis Retention</term>
<term>Humans</term>
<term>Male</term>
<term>Surface Properties</term>
<term>Vibration</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Arcade dentaire</term>
<term>Cadavre</term>
<term>Densité osseuse</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule</term>
<term>Maxillaire</term>
<term>Mâchoire édentée</term>
<term>Mâle</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Propriétés de surface</term>
<term>Rétention de prothèse dentaire</term>
<term>Sujet âgé de 80 ans ou plus</term>
<term>Vibration</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">An electronically controlled mechanical tapping device (MTD) to measure implant stability has been studied extensively for its ability to measure initial stability at the time of surgical placement and predict an implant's survival prognosis, with few reported complications.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">19905957</PMID>
<DateCompleted>
<Year>2009</Year>
<Month>12</Month>
<Day>22</Day>
</DateCompleted>
<DateRevised>
<Year>2009</Year>
<Month>11</Month>
<Day>12</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1943-3670</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>80</Volume>
<Issue>11</Issue>
<PubDate>
<Year>2009</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal of periodontology</Title>
<ISOAbbreviation>J. Periodontol.</ISOAbbreviation>
</Journal>
<ArticleTitle>Potential damage to bone-implant interface when measuring initial implant stability.</ArticleTitle>
<Pagination>
<MedlinePgn>1868-74</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1902/jop.2009.090169</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">An electronically controlled mechanical tapping device (MTD) to measure implant stability has been studied extensively for its ability to measure initial stability at the time of surgical placement and predict an implant's survival prognosis, with few reported complications.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Initial stability data, measured repeatedly with a resonance frequency analysis device and the MTD, for seven of 28 implants placed in jawbones of four fresh human cadavers and the histologic images of bone-implant interfaces are presented as evidence for potential damage to the bone-implant interface using these techniques.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">A progressive increase in mobility from stable (-1) to less stable (4) and eventually to visibly mobile (999) was observed after three measurements with the MTD. Corresponding histologic images revealed that the buccal threads in the coronal half of the implants were displaced lingually and apically from the bony indentations that were created during insertion of the self-threading implants, subsequent to repeated MTD measurements in the buccal and axial directions. The histologic images and changes in MTD values indicated that repeated MTD measurements at the time of implant placement surgery may damage the bone-implant interface, and a stable or borderline implant may become mobile after repeated MTD measurements.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Histologic images showed potential damage to the bone-implant interface during repeated initial implant-stability measurements using the MTD. Initial implant-stability measurements using the MTD should be performed with caution, and they may be contraindicated for implants placed in low-quality bone.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Seong</LastName>
<ForeName>Wook-Jin</ForeName>
<Initials>WJ</Initials>
<AffiliationInfo>
<Affiliation>Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA. seong001@umn.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Conrad</LastName>
<ForeName>Heather J</ForeName>
<Initials>HJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hinrichs</LastName>
<ForeName>James E</ForeName>
<Initials>JE</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<GrantList CompleteYN="Y">
<Grant>
<GrantID>R21-DE015410</GrantID>
<Acronym>DE</Acronym>
<Agency>NIDCR NIH HHS</Agency>
<Country>United States</Country>
</Grant>
</GrantList>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D052061">Research Support, N.I.H., Extramural</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Periodontol</MedlineTA>
<NlmUniqueID>8000345</NlmUniqueID>
<ISSNLinking>0022-3492</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015519" MajorTopicYN="N">Bone Density</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002102" MajorTopicYN="N">Cadaver</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003724" MajorTopicYN="N">Dental Arch</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017268" MajorTopicYN="Y">Dental Prosthesis Retention</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008338" MajorTopicYN="N">Mandibular Injuries</DescriptorName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008440" MajorTopicYN="N">Maxillary Fractures</DescriptorName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014732" MajorTopicYN="N">Vibration</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2009</Year>
<Month>11</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2009</Year>
<Month>11</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2009</Year>
<Month>12</Month>
<Day>23</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">19905957</ArticleId>
<ArticleId IdType="doi">10.1902/jop.2009.090169</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001B75 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001B75 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:19905957
   |texte=   Potential damage to bone-implant interface when measuring initial implant stability.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:19905957" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022