Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.

Identifieur interne : 001202 ( PubMed/Curation ); précédent : 001201; suivant : 001203

Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.

Auteurs : Marianna Guanaes Gomes Torres [Brésil] ; Paulo Sérgio Flores Campos ; Nilson Pena Neto Segundo ; Marcus Navarro ; Iêda Crusoé-Rebello

Source :

RBID : pubmed:22382754

Descripteurs français

English descriptors

Abstract

To evaluate the accuracy of linear measurements on dry mandible specimens using cone beam computed tomography (CBCT) images acquired with different voxel sizes.

DOI: 10.1097/ID.0b013e31824bf93c
PubMed: 22382754

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:22382754

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.</title>
<author>
<name sortKey="Torres, Marianna Guanaes Gomes" sort="Torres, Marianna Guanaes Gomes" uniqKey="Torres M" first="Marianna Guanaes Gomes" last="Torres">Marianna Guanaes Gomes Torres</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Radiology, School of Dentistry, Federal University of Bahia, Salvador, BA, Brazil. torresmarianna@hotmail.com</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Department of Oral and Maxillofacial Radiology, School of Dentistry, Federal University of Bahia, Salvador, BA</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Campos, Paulo Sergio Flores" sort="Campos, Paulo Sergio Flores" uniqKey="Campos P" first="Paulo Sérgio Flores" last="Campos">Paulo Sérgio Flores Campos</name>
</author>
<author>
<name sortKey="Segundo, Nilson Pena Neto" sort="Segundo, Nilson Pena Neto" uniqKey="Segundo N" first="Nilson Pena Neto" last="Segundo">Nilson Pena Neto Segundo</name>
</author>
<author>
<name sortKey="Navarro, Marcus" sort="Navarro, Marcus" uniqKey="Navarro M" first="Marcus" last="Navarro">Marcus Navarro</name>
</author>
<author>
<name sortKey="Crusoe Rebello, Ieda" sort="Crusoe Rebello, Ieda" uniqKey="Crusoe Rebello I" first="Iêda" last="Crusoé-Rebello">Iêda Crusoé-Rebello</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22382754</idno>
<idno type="pmid">22382754</idno>
<idno type="doi">10.1097/ID.0b013e31824bf93c</idno>
<idno type="wicri:Area/PubMed/Corpus">001202</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001202</idno>
<idno type="wicri:Area/PubMed/Curation">001202</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">001202</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.</title>
<author>
<name sortKey="Torres, Marianna Guanaes Gomes" sort="Torres, Marianna Guanaes Gomes" uniqKey="Torres M" first="Marianna Guanaes Gomes" last="Torres">Marianna Guanaes Gomes Torres</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Oral and Maxillofacial Radiology, School of Dentistry, Federal University of Bahia, Salvador, BA, Brazil. torresmarianna@hotmail.com</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Department of Oral and Maxillofacial Radiology, School of Dentistry, Federal University of Bahia, Salvador, BA</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Campos, Paulo Sergio Flores" sort="Campos, Paulo Sergio Flores" uniqKey="Campos P" first="Paulo Sérgio Flores" last="Campos">Paulo Sérgio Flores Campos</name>
</author>
<author>
<name sortKey="Segundo, Nilson Pena Neto" sort="Segundo, Nilson Pena Neto" uniqKey="Segundo N" first="Nilson Pena Neto" last="Segundo">Nilson Pena Neto Segundo</name>
</author>
<author>
<name sortKey="Navarro, Marcus" sort="Navarro, Marcus" uniqKey="Navarro M" first="Marcus" last="Navarro">Marcus Navarro</name>
</author>
<author>
<name sortKey="Crusoe Rebello, Ieda" sort="Crusoe Rebello, Ieda" uniqKey="Crusoe Rebello I" first="Iêda" last="Crusoé-Rebello">Iêda Crusoé-Rebello</name>
</author>
</analytic>
<series>
<title level="j">Implant dentistry</title>
<idno type="eISSN">1538-2982</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Alveolar Bone Loss (diagnostic imaging)</term>
<term>Anatomic Landmarks (diagnostic imaging)</term>
<term>Calibration</term>
<term>Cephalometry (standards)</term>
<term>Cone-Beam Computed Tomography (standards)</term>
<term>Dental Arch (diagnostic imaging)</term>
<term>Dental Implantation, Endosseous</term>
<term>Fiducial Markers</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted (standards)</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Patient Care Planning (standards)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Arcade dentaire (imagerie diagnostique)</term>
<term>Calibrage</term>
<term>Céphalométrie (normes)</term>
<term>Humains</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Marques de positionnement</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Planification des soins du patient (normes)</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Repères anatomiques (imagerie diagnostique)</term>
<term>Résorption alvéolaire (imagerie diagnostique)</term>
<term>Tomodensitométrie à faisceau conique (normes)</term>
<term>Traitement d'image par ordinateur (normes)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Alveolar Bone Loss</term>
<term>Anatomic Landmarks</term>
<term>Dental Arch</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Arcade dentaire</term>
<term>Mandibule</term>
<term>Mâchoire édentée</term>
<term>Repères anatomiques</term>
<term>Résorption alvéolaire</term>
</keywords>
<keywords scheme="MESH" qualifier="normes" xml:lang="fr">
<term>Céphalométrie</term>
<term>Planification des soins du patient</term>
<term>Tomodensitométrie à faisceau conique</term>
<term>Traitement d'image par ordinateur</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Cephalometry</term>
<term>Cone-Beam Computed Tomography</term>
<term>Image Processing, Computer-Assisted</term>
<term>Patient Care Planning</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Calibration</term>
<term>Dental Implantation, Endosseous</term>
<term>Fiducial Markers</term>
<term>Humans</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Calibrage</term>
<term>Humains</term>
<term>Marques de positionnement</term>
<term>Pose d'implant dentaire endo-osseux</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To evaluate the accuracy of linear measurements on dry mandible specimens using cone beam computed tomography (CBCT) images acquired with different voxel sizes.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">22382754</PMID>
<DateCompleted>
<Year>2012</Year>
<Month>09</Month>
<Day>25</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1538-2982</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>21</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2012</Year>
<Month>Apr</Month>
</PubDate>
</JournalIssue>
<Title>Implant dentistry</Title>
<ISOAbbreviation>Implant Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.</ArticleTitle>
<Pagination>
<MedlinePgn>150-5</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1097/ID.0b013e31824bf93c</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">To evaluate the accuracy of linear measurements on dry mandible specimens using cone beam computed tomography (CBCT) images acquired with different voxel sizes.</AbstractText>
<AbstractText Label="METHODOLOGY" NlmCategory="METHODS">Eight human dry mandibles were submitted to CBCT examination, using the i-CAT (Imaging Sciences, Inc. Hatfield, PA) device and four protocols with different voxel sizes. Tomographic slices with a more central view of the markers, placed on six sites on each mandible, were selected to perform measurements. Values obtained from direct measurements on the dry mandible after sectioning them on the preestablished sites were compared with measurements from the tomographic images and the measurement error.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There was no statistical difference between the measurement error of the protocols (P = 0.606). The mean value of the difference between the values obtained in the images and the dry mandible was smaller than 1 mm for all the protocols.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The accuracy of vertical and horizontal measurements, using CBCT (i-CAT) for the four protocols, was shown to be comparable with the measurements performed on the dry mandible.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Torres</LastName>
<ForeName>Marianna Guanaes Gomes</ForeName>
<Initials>MG</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Radiology, School of Dentistry, Federal University of Bahia, Salvador, BA, Brazil. torresmarianna@hotmail.com</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Campos</LastName>
<ForeName>Paulo Sérgio Flores</ForeName>
<Initials>PS</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Segundo</LastName>
<ForeName>Nilson Pena Neto</ForeName>
<Initials>NP</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Navarro</LastName>
<ForeName>Marcus</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Crusoé-Rebello</LastName>
<ForeName>Iêda</ForeName>
<Initials>I</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Implant Dent</MedlineTA>
<NlmUniqueID>9206481</NlmUniqueID>
<ISSNLinking>1056-6163</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D016301" MajorTopicYN="N">Alveolar Bone Loss</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D059925" MajorTopicYN="N">Anatomic Landmarks</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002138" MajorTopicYN="N">Calibration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002508" MajorTopicYN="N">Cephalometry</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D054893" MajorTopicYN="N">Cone-Beam Computed Tomography</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003724" MajorTopicYN="N">Dental Arch</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D057918" MajorTopicYN="N">Fiducial Markers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007091" MajorTopicYN="N">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="N">standards</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>3</Month>
<Day>3</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>3</Month>
<Day>3</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>9</Month>
<Day>26</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">22382754</ArticleId>
<ArticleId IdType="doi">10.1097/ID.0b013e31824bf93c</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001202 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 001202 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:22382754
   |texte=   Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:22382754" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022