Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.

Identifieur interne : 000971 ( PubMed/Curation ); précédent : 000970; suivant : 000972

Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.

Auteurs : Frederico S. Neves [Brésil] ; Taruska V. Vasconcelos ; Paulo S F. Campos ; Francisco Haiter-Neto ; Deborah Q. Freitas

Source :

RBID : pubmed:23231370

Descripteurs français

English descriptors

Abstract

The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements.

DOI: 10.1111/clr.12080
PubMed: 23231370

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:23231370

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.</title>
<author>
<name sortKey="Neves, Frederico S" sort="Neves, Frederico S" uniqKey="Neves F" first="Frederico S" last="Neves">Frederico S. Neves</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil.</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Vasconcelos, Taruska V" sort="Vasconcelos, Taruska V" uniqKey="Vasconcelos T" first="Taruska V" last="Vasconcelos">Taruska V. Vasconcelos</name>
</author>
<author>
<name sortKey="Campos, Paulo S F" sort="Campos, Paulo S F" uniqKey="Campos P" first="Paulo S F" last="Campos">Paulo S F. Campos</name>
</author>
<author>
<name sortKey="Haiter Neto, Francisco" sort="Haiter Neto, Francisco" uniqKey="Haiter Neto F" first="Francisco" last="Haiter-Neto">Francisco Haiter-Neto</name>
</author>
<author>
<name sortKey="Freitas, Deborah Q" sort="Freitas, Deborah Q" uniqKey="Freitas D" first="Deborah Q" last="Freitas">Deborah Q. Freitas</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2014">2014</date>
<idno type="RBID">pubmed:23231370</idno>
<idno type="pmid">23231370</idno>
<idno type="doi">10.1111/clr.12080</idno>
<idno type="wicri:Area/PubMed/Corpus">000971</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000971</idno>
<idno type="wicri:Area/PubMed/Curation">000971</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000971</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.</title>
<author>
<name sortKey="Neves, Frederico S" sort="Neves, Frederico S" uniqKey="Neves F" first="Frederico S" last="Neves">Frederico S. Neves</name>
<affiliation wicri:level="1">
<nlm:affiliation>Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil.</nlm:affiliation>
<country xml:lang="fr">Brésil</country>
<wicri:regionArea>Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Vasconcelos, Taruska V" sort="Vasconcelos, Taruska V" uniqKey="Vasconcelos T" first="Taruska V" last="Vasconcelos">Taruska V. Vasconcelos</name>
</author>
<author>
<name sortKey="Campos, Paulo S F" sort="Campos, Paulo S F" uniqKey="Campos P" first="Paulo S F" last="Campos">Paulo S F. Campos</name>
</author>
<author>
<name sortKey="Haiter Neto, Francisco" sort="Haiter Neto, Francisco" uniqKey="Haiter Neto F" first="Francisco" last="Haiter-Neto">Francisco Haiter-Neto</name>
</author>
<author>
<name sortKey="Freitas, Deborah Q" sort="Freitas, Deborah Q" uniqKey="Freitas D" first="Deborah Q" last="Freitas">Deborah Q. Freitas</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="eISSN">1600-0501</idno>
<imprint>
<date when="2014" type="published">2014</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Alveolar Bone Loss (diagnostic imaging)</term>
<term>Cone-Beam Computed Tomography</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Mandible (surgery)</term>
<term>Reproducibility of Results</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule ()</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Mâchoire édentée ()</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Reproductibilité des résultats</term>
<term>Résorption alvéolaire (imagerie diagnostique)</term>
<term>Techniques in vitro</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Alveolar Bone Loss</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mandibule</term>
<term>Mâchoire édentée</term>
<term>Résorption alvéolaire</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Cone-Beam Computed Tomography</term>
<term>Dental Implantation, Endosseous</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Reproducibility of Results</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Humains</term>
<term>Implants dentaires</term>
<term>Mandibule</term>
<term>Mâchoire édentée</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Reproductibilité des résultats</term>
<term>Techniques in vitro</term>
<term>Tomodensitométrie à faisceau conique</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23231370</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>04</Month>
<Day>11</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1600-0501</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>25</Volume>
<Issue>2</Issue>
<PubDate>
<Year>2014</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.</ArticleTitle>
<Pagination>
<MedlinePgn>e155-8</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/clr.12080</ELocationID>
<Abstract>
<AbstractText Label="OBJECTIVE" NlmCategory="OBJECTIVE">The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">Completely edentulous mandibles with entirely resorbed alveolar processes were selected for this study. Five regions were selected (incisor, canine, premolar, first molar, and second molar). The mandibles were scanned with Next Generation i-CAT CBCT unit (Imaging Sciences International, Inc, Hatfield, PA, USA) with half (180°) and full (360°) mode. Two oral radiologists performed vertical measurements in all selected regions; the measurements of half of the sample were repeated within an interval of 30 days. The mandibles were sectioned using an electrical saw in all evaluated regions to obtain the gold standard. The intraclass correlation coefficient was calculated for the intra- and interobserver agreement. Descriptive statistics were calculated as mean, median, and standard deviation. Wilcoxon signed rank test was used to determine the correlation between the measurements obtained in different scan mode with the gold standard. The significance level was 5%.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The values of intra- and interobserver reproducibility indicated a strong agreement. In the dental implant measurements, except the bone height of the second molar region in full scan mode (P = 0.02), the Wilcoxon signed rank test did not show statistical significant difference with the gold standard (P > 0.05).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Both modes provided real measures, necessary when performing implant planning; however, half scan mode uses smaller doses, following the principle of effectiveness. We believe that this method should be used because of the best dose-effect relationship and offer less risk to the patient.</AbstractText>
<CopyrightInformation>© 2012 John Wiley & Sons A/S.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Neves</LastName>
<ForeName>Frederico S</ForeName>
<Initials>FS</Initials>
<AffiliationInfo>
<Affiliation>Division of Oral Radiology, Department of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Vasconcelos</LastName>
<ForeName>Taruska V</ForeName>
<Initials>TV</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Campos</LastName>
<ForeName>Paulo S F</ForeName>
<Initials>PS</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Haiter-Neto</LastName>
<ForeName>Francisco</ForeName>
<Initials>F</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Freitas</LastName>
<ForeName>Deborah Q</ForeName>
<Initials>DQ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2012</Year>
<Month>12</Month>
<Day>12</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D016301" MajorTopicYN="N">Alveolar Bone Loss</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D054893" MajorTopicYN="Y">Cone-Beam Computed Tomography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D066298" MajorTopicYN="N">In Vitro Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">cone beam computed tomography</Keyword>
<Keyword MajorTopicYN="N">dental implants</Keyword>
<Keyword MajorTopicYN="N">mandible</Keyword>
<Keyword MajorTopicYN="N">measurements</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="accepted">
<Year>2012</Year>
<Month>10</Month>
<Day>15</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2012</Year>
<Month>12</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2012</Year>
<Month>12</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>4</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23231370</ArticleId>
<ArticleId IdType="doi">10.1111/clr.12080</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000971 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd -nk 000971 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:23231370
   |texte=   Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Curation/RBID.i   -Sk "pubmed:23231370" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022