Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.

Identifieur interne : 004503 ( PubMed/Corpus ); précédent : 004502; suivant : 004504

Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.

Auteurs : R. Mericske-Stern

Source :

RBID : pubmed:8150514

English descriptors

Abstract

The capacity of dentate subjects to discriminate the thickness of objects placed between the teeth seems to depend on receptors in the periodontal ligament and muscles. The compensatory mechanism of ankylotic implants for the function of missing periodontal ligaments is not yet known. To investigate this question in overdenture wearers, 26 patients with ITI implants and 20 patients with natural roots were selected. According to the experimental protocol, the discriminatory ability was recorded with 10 steel foils (thickness ranging from 10 to 100 microns) placed between the premolars. Each thickness was tested 10 times and the test subjects were required to distinguish whether foil was positioned between the teeth. A maximum of 100 correct or 100 incorrect answers was possible. The average number of incorrect answers was significantly higher in test subjects with implants. The 50% limit (ie, the tested thickness recorded with at least 5 wrong answers) was established, but no statistically significant difference was found. In both groups, the critical tactile threshold of perceived thickness was 30 to 40 microns, with 2 being the average number of incorrect assessments. When comparing the minimal thickness, which was recorded without incorrect assessment, a significantly lower threshold was observed on patients with natural roots. Thus, active tactile sensibility appears to depend on the receptors in the periodontal ligament. However, wearing of removable prostheses is a modifying factor and may influence the oral tactile sensibility for both groups.

PubMed: 8150514

Links to Exploration step

pubmed:8150514

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.</title>
<author>
<name sortKey="Mericske Stern, R" sort="Mericske Stern, R" uniqKey="Mericske Stern R" first="R" last="Mericske-Stern">R. Mericske-Stern</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, School of Dental Medicine, University of Bern, Switzerland.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>1994 Jan-Feb</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:8150514</idno>
<idno type="pmid">8150514</idno>
<idno type="wicri:Area/PubMed/Corpus">004503</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004503</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.</title>
<author>
<name sortKey="Mericske Stern, R" sort="Mericske Stern, R" uniqKey="Mericske Stern R" first="R" last="Mericske-Stern">R. Mericske-Stern</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, School of Dental Medicine, University of Bern, Switzerland.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="ISSN">0882-2786</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Dental Implants</term>
<term>Dental Occlusion</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous</term>
<term>Male</term>
<term>Mandible</term>
<term>Mechanoreceptors (physiology)</term>
<term>Middle Aged</term>
<term>Periodontal Ligament (innervation)</term>
<term>Sensory Thresholds</term>
<term>Tooth Root (physiology)</term>
<term>Touch (physiology)</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="innervation" xml:lang="en">
<term>Periodontal Ligament</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Mechanoreceptors</term>
<term>Tooth Root</term>
<term>Touch</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Dental Occlusion</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous</term>
<term>Male</term>
<term>Mandible</term>
<term>Middle Aged</term>
<term>Sensory Thresholds</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The capacity of dentate subjects to discriminate the thickness of objects placed between the teeth seems to depend on receptors in the periodontal ligament and muscles. The compensatory mechanism of ankylotic implants for the function of missing periodontal ligaments is not yet known. To investigate this question in overdenture wearers, 26 patients with ITI implants and 20 patients with natural roots were selected. According to the experimental protocol, the discriminatory ability was recorded with 10 steel foils (thickness ranging from 10 to 100 microns) placed between the premolars. Each thickness was tested 10 times and the test subjects were required to distinguish whether foil was positioned between the teeth. A maximum of 100 correct or 100 incorrect answers was possible. The average number of incorrect answers was significantly higher in test subjects with implants. The 50% limit (ie, the tested thickness recorded with at least 5 wrong answers) was established, but no statistically significant difference was found. In both groups, the critical tactile threshold of perceived thickness was 30 to 40 microns, with 2 being the average number of incorrect assessments. When comparing the minimal thickness, which was recorded without incorrect assessment, a significantly lower threshold was observed on patients with natural roots. Thus, active tactile sensibility appears to depend on the receptors in the periodontal ligament. However, wearing of removable prostheses is a modifying factor and may influence the oral tactile sensibility for both groups.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">8150514</PMID>
<DateCompleted>
<Year>1994</Year>
<Month>05</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0882-2786</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>9</Volume>
<Issue>1</Issue>
<PubDate>
<MedlineDate>1994 Jan-Feb</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of oral & maxillofacial implants</Title>
<ISOAbbreviation>Int J Oral Maxillofac Implants</ISOAbbreviation>
</Journal>
<ArticleTitle>Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.</ArticleTitle>
<Pagination>
<MedlinePgn>63-70</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The capacity of dentate subjects to discriminate the thickness of objects placed between the teeth seems to depend on receptors in the periodontal ligament and muscles. The compensatory mechanism of ankylotic implants for the function of missing periodontal ligaments is not yet known. To investigate this question in overdenture wearers, 26 patients with ITI implants and 20 patients with natural roots were selected. According to the experimental protocol, the discriminatory ability was recorded with 10 steel foils (thickness ranging from 10 to 100 microns) placed between the premolars. Each thickness was tested 10 times and the test subjects were required to distinguish whether foil was positioned between the teeth. A maximum of 100 correct or 100 incorrect answers was possible. The average number of incorrect answers was significantly higher in test subjects with implants. The 50% limit (ie, the tested thickness recorded with at least 5 wrong answers) was established, but no statistically significant difference was found. In both groups, the critical tactile threshold of perceived thickness was 30 to 40 microns, with 2 being the average number of incorrect assessments. When comparing the minimal thickness, which was recorded without incorrect assessment, a significantly lower threshold was observed on patients with natural roots. Thus, active tactile sensibility appears to depend on the receptors in the periodontal ligament. However, wearing of removable prostheses is a modifying factor and may influence the oral tactile sensibility for both groups.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Mericske-Stern</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
<AffiliationInfo>
<Affiliation>Department of Removable Prosthodontics, School of Dental Medicine, University of Bern, Switzerland.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Int J Oral Maxillofac Implants</MedlineTA>
<NlmUniqueID>8611905</NlmUniqueID>
<ISSNLinking>0882-2786</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<CitationSubset>S</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003766" MajorTopicYN="N">Dental Occlusion</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008465" MajorTopicYN="N">Mechanoreceptors</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010513" MajorTopicYN="N">Periodontal Ligament</DescriptorName>
<QualifierName UI="Q000294" MajorTopicYN="N">innervation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012684" MajorTopicYN="N">Sensory Thresholds</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014092" MajorTopicYN="N">Tooth Root</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014110" MajorTopicYN="N">Touch</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1994</Year>
<Month>1</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1994</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1994</Year>
<Month>1</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8150514</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004503 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 004503 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:8150514
   |texte=   Oral tactile sensibility recorded in overdenture wearers with implants or natural roots: a comparative study. Part 2.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:8150514" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022