Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report.
Identifieur interne : 004394 ( PubMed/Corpus ); précédent : 004393; suivant : 004395Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report.
Auteurs : T. JemtSource :
- Clinical oral implants research [ 0905-7161 ] ; 1994.
English descriptors
- KwdEn :
- Adult, Aged, Alveolar Bone Loss (etiology), Dental Implantation, Endosseous, Dental Implants (adverse effects), Dental Prosthesis, Dental Prosthesis Design, Female, Follow-Up Studies, Humans, Jaw, Edentulous (rehabilitation), Male, Maxilla, Middle Aged, Prosthesis Failure, Speech Disorders (etiology), Treatment Outcome.
- MESH :
- chemical , adverse effects : Dental Implants.
- etiology : Alveolar Bone Loss, Speech Disorders.
- rehabilitation : Jaw, Edentulous.
- Adult, Aged, Dental Implantation, Endosseous, Dental Prosthesis, Dental Prosthesis Design, Female, Follow-Up Studies, Humans, Male, Maxilla, Middle Aged, Prosthesis Failure, Treatment Outcome.
Abstract
Seventy-six patients were consecutively treated with fixed prostheses supported by osseointegrated implants in the edentulous maxilla and followed up for 5 years. The mean bone quality and resorption indices were 3.1 and 2.7 at the time of implant placement, respectively. Altogether, 449 standard Brånemark implants were placed. Two patients resumed to complete dentures, and the cumulative implant and prosthesis survival rates were 92.1% and 95.9% for 5 years, respectively. The mean marginal bone level was 0.6 mm below the reference point at the time of placement and 1.2 mm below the same point 5 years later. Speech problems was the most frequent complaint during the first year of function, while resin fractures caused most adjustments during the follow-up period. No implant, abutment or gold alloy screws were found to be fractured, and only 4 patients had their prostheses re-tightened due to loose gold alloy screws.
PubMed: 7827228
Links to Exploration step
pubmed:7827228Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report.</title>
<author><name sortKey="Jemt, T" sort="Jemt, T" uniqKey="Jemt T" first="T" last="Jemt">T. Jemt</name>
<affiliation><nlm:affiliation>The Brånemark Clinic, Public Dental Health and Faculty of Odontology, University of Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1994">1994</date>
<idno type="RBID">pubmed:7827228</idno>
<idno type="pmid">7827228</idno>
<idno type="wicri:Area/PubMed/Corpus">004394</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004394</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report.</title>
<author><name sortKey="Jemt, T" sort="Jemt, T" uniqKey="Jemt T" first="T" last="Jemt">T. Jemt</name>
<affiliation><nlm:affiliation>The Brånemark Clinic, Public Dental Health and Faculty of Odontology, University of Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series><title level="j">Clinical oral implants research</title>
<idno type="ISSN">0905-7161</idno>
<imprint><date when="1994" type="published">1994</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Aged</term>
<term>Alveolar Bone Loss (etiology)</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Implants (adverse effects)</term>
<term>Dental Prosthesis</term>
<term>Dental Prosthesis Design</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Male</term>
<term>Maxilla</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Speech Disorders (etiology)</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="adverse effects" xml:lang="en"><term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Alveolar Bone Loss</term>
<term>Speech Disorders</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Aged</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis</term>
<term>Dental Prosthesis Design</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Male</term>
<term>Maxilla</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Seventy-six patients were consecutively treated with fixed prostheses supported by osseointegrated implants in the edentulous maxilla and followed up for 5 years. The mean bone quality and resorption indices were 3.1 and 2.7 at the time of implant placement, respectively. Altogether, 449 standard Brånemark implants were placed. Two patients resumed to complete dentures, and the cumulative implant and prosthesis survival rates were 92.1% and 95.9% for 5 years, respectively. The mean marginal bone level was 0.6 mm below the reference point at the time of placement and 1.2 mm below the same point 5 years later. Speech problems was the most frequent complaint during the first year of function, while resin fractures caused most adjustments during the follow-up period. No implant, abutment or gold alloy screws were found to be fractured, and only 4 patients had their prostheses re-tightened due to loose gold alloy screws.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">7827228</PMID>
<DateCompleted><Year>1995</Year>
<Month>02</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised><Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0905-7161</ISSN>
<JournalIssue CitedMedium="Print"><Volume>5</Volume>
<Issue>3</Issue>
<PubDate><Year>1994</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report.</ArticleTitle>
<Pagination><MedlinePgn>142-7</MedlinePgn>
</Pagination>
<Abstract><AbstractText>Seventy-six patients were consecutively treated with fixed prostheses supported by osseointegrated implants in the edentulous maxilla and followed up for 5 years. The mean bone quality and resorption indices were 3.1 and 2.7 at the time of implant placement, respectively. Altogether, 449 standard Brånemark implants were placed. Two patients resumed to complete dentures, and the cumulative implant and prosthesis survival rates were 92.1% and 95.9% for 5 years, respectively. The mean marginal bone level was 0.6 mm below the reference point at the time of placement and 1.2 mm below the same point 5 years later. Speech problems was the most frequent complaint during the first year of function, while resin fractures caused most adjustments during the follow-up period. No implant, abutment or gold alloy screws were found to be fractured, and only 4 patients had their prostheses re-tightened due to loose gold alloy screws.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Jemt</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
<AffiliationInfo><Affiliation>The Brånemark Clinic, Public Dental Health and Faculty of Odontology, University of Göteborg, Sweden.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D016301" MajorTopicYN="N">Alveolar Bone Loss</DescriptorName>
<QualifierName UI="Q000209" MajorTopicYN="Y">etiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017266" MajorTopicYN="Y">Dental Prosthesis</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="Y">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011475" MajorTopicYN="N">Prosthesis Failure</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D013064" MajorTopicYN="N">Speech Disorders</DescriptorName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D016896" MajorTopicYN="N">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>1994</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>1994</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>1994</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">7827228</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004394 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 004394 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:7827228 |texte= Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:7827228" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |