Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.

Identifieur interne : 004044 ( PubMed/Corpus ); précédent : 004043; suivant : 004045

In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.

Auteurs : R. Mericske-Stern ; G A Zarb

Source :

RBID : pubmed:9002834

English descriptors

Abstract

Maximal occlusal force and oral tactile sensibility were recorded in 21 edentulous patients wearing maxillary complete dentures and mandibular fixed prostheses supported by Brånemark implants. Bite force was measured with a miniature force transducer between antagonistic molars and premolars, and the passive tactile sensibility of the fixtures was recorded in the horizontal and vertical directions with spring balances. The active tactile sensibility was tested using steel foils (100 to 10 microns). The range of maximal occlusal force recorded was from 35 to 330N with highest values observed on the second premolars (mean 143N). Significantly lower forces were found on molars and first premolars (p < 0.01). The detection threshold of minimal pressure was about 330 g in the horizontal, and 388 g in the vertical direction. This difference was not statistically significant. The average number of incorrect assessments when testing steel foils was 16.6 errors, out of 100 recordings. Similar results when using these 3 test modalities had been found on overdentures supported by two mandibular implants and occluding with maxillary complete dentures. The results of this study suggest that mandibular implants supporting fixed prostheses are not likely to improve oral tactile sensibility and maximal occlusal force in the presence of maxillary complete dentures.

PubMed: 9002834

Links to Exploration step

pubmed:9002834

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.</title>
<author>
<name sortKey="Mericske Stern, R" sort="Mericske Stern, R" uniqKey="Mericske Stern R" first="R" last="Mericske-Stern">R. Mericske-Stern</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, University of Bern, Switzerland.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zarb, G A" sort="Zarb, G A" uniqKey="Zarb G" first="G A" last="Zarb">G A Zarb</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1996">1996</date>
<idno type="RBID">pubmed:9002834</idno>
<idno type="pmid">9002834</idno>
<idno type="wicri:Area/PubMed/Corpus">004044</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004044</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.</title>
<author>
<name sortKey="Mericske Stern, R" sort="Mericske Stern, R" uniqKey="Mericske Stern R" first="R" last="Mericske-Stern">R. Mericske-Stern</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, University of Bern, Switzerland.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Zarb, G A" sort="Zarb, G A" uniqKey="Zarb G" first="G A" last="Zarb">G A Zarb</name>
</author>
</analytic>
<series>
<title level="j">Clinical oral implants research</title>
<idno type="ISSN">0905-7161</idno>
<imprint>
<date when="1996" type="published">1996</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Bite Force</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Complete, Upper</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Humans</term>
<term>Jaw, Edentulous (physiopathology)</term>
<term>Male</term>
<term>Mandible (physiopathology)</term>
<term>Middle Aged</term>
<term>Mouth, Edentulous (rehabilitation)</term>
<term>Proprioception</term>
<term>Sensory Thresholds</term>
<term>Statistics, Nonparametric</term>
<term>Touch (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Touch</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Mouth, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Bite Force</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Complete, Upper</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Proprioception</term>
<term>Sensory Thresholds</term>
<term>Statistics, Nonparametric</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Maximal occlusal force and oral tactile sensibility were recorded in 21 edentulous patients wearing maxillary complete dentures and mandibular fixed prostheses supported by Brånemark implants. Bite force was measured with a miniature force transducer between antagonistic molars and premolars, and the passive tactile sensibility of the fixtures was recorded in the horizontal and vertical directions with spring balances. The active tactile sensibility was tested using steel foils (100 to 10 microns). The range of maximal occlusal force recorded was from 35 to 330N with highest values observed on the second premolars (mean 143N). Significantly lower forces were found on molars and first premolars (p < 0.01). The detection threshold of minimal pressure was about 330 g in the horizontal, and 388 g in the vertical direction. This difference was not statistically significant. The average number of incorrect assessments when testing steel foils was 16.6 errors, out of 100 recordings. Similar results when using these 3 test modalities had been found on overdentures supported by two mandibular implants and occluding with maxillary complete dentures. The results of this study suggest that mandibular implants supporting fixed prostheses are not likely to improve oral tactile sensibility and maximal occlusal force in the presence of maxillary complete dentures.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">9002834</PMID>
<DateCompleted>
<Year>1997</Year>
<Month>02</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0905-7161</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>7</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1996</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Clinical oral implants research</Title>
<ISOAbbreviation>Clin Oral Implants Res</ISOAbbreviation>
</Journal>
<ArticleTitle>In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.</ArticleTitle>
<Pagination>
<MedlinePgn>153-61</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Maximal occlusal force and oral tactile sensibility were recorded in 21 edentulous patients wearing maxillary complete dentures and mandibular fixed prostheses supported by Brånemark implants. Bite force was measured with a miniature force transducer between antagonistic molars and premolars, and the passive tactile sensibility of the fixtures was recorded in the horizontal and vertical directions with spring balances. The active tactile sensibility was tested using steel foils (100 to 10 microns). The range of maximal occlusal force recorded was from 35 to 330N with highest values observed on the second premolars (mean 143N). Significantly lower forces were found on molars and first premolars (p < 0.01). The detection threshold of minimal pressure was about 330 g in the horizontal, and 388 g in the vertical direction. This difference was not statistically significant. The average number of incorrect assessments when testing steel foils was 16.6 errors, out of 100 recordings. Similar results when using these 3 test modalities had been found on overdentures supported by two mandibular implants and occluding with maxillary complete dentures. The results of this study suggest that mandibular implants supporting fixed prostheses are not likely to improve oral tactile sensibility and maximal occlusal force in the presence of maxillary complete dentures.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Mericske-Stern</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
<AffiliationInfo>
<Affiliation>Department of Removable Prosthodontics, University of Bern, Switzerland.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Zarb</LastName>
<ForeName>G A</ForeName>
<Initials>GA</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Denmark</Country>
<MedlineTA>Clin Oral Implants Res</MedlineTA>
<NlmUniqueID>9105713</NlmUniqueID>
<ISSNLinking>0905-7161</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001732" MajorTopicYN="Y">Bite Force</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003827" MajorTopicYN="N">Denture, Complete, Upper</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="N">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D009066" MajorTopicYN="N">Mouth, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011434" MajorTopicYN="N">Proprioception</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012684" MajorTopicYN="N">Sensory Thresholds</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D018709" MajorTopicYN="N">Statistics, Nonparametric</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014110" MajorTopicYN="N">Touch</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1996</Year>
<Month>6</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1996</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1996</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">9002834</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004044 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 004044 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:9002834
   |texte=   In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:9002834" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022