Prosthesis misfit and marginal bone loss in edentulous implant patients.

Identifieur interne : 003F98 ( PubMed/Corpus ); précédent : 003F97; suivant : 003F99

Prosthesis misfit and marginal bone loss in edentulous implant patients.

Auteurs : T. Jemt ; K. Book

Source :

RBID : pubmed:8908860

English descriptors

Abstract

The objective of this study was to statistically correlate in vivo measurements of prosthesis misfit and change of marginal bone level in implants placed in the edentulous maxilla. Two groups, each comprising seven patients, were followed up either prospectively for 1 year or retrospectively for the last 4 years of the 5-year period after second-stage surgery. Measurements of prosthesis misfit were performed by means of a three-dimensional photogrammetric technique, and marginal bone levels were measured from standard intraoral radiographs. Results showed that none of the prostheses presented a completely passive fit to the implants in vivo. Furthermore, similar distortions of the prostheses were found in the two groups, indicating that the implants seemed to be stable and did not move, even after several years in function. The maximal range of three-dimensional distortion of cylinder center points was about 275 microns for both groups. Mean center point misfit was 111 (SD 59) and 91 (SD 51) microns for the 1-year and 5-year groups, respectively. The corresponding mean marginal bone loss was 0.5 and 0.2 mm for the two follow-up groups. No statistical correlations (P > .05) between change of marginal bone levels and different parameters of prosthesis misfit were observed in the two groups. The study indicated that a certain biologic tolerance for misfit may be present. The degree of misfit reported in the study was clinically acceptable with regard to observed marginal bone loss.

PubMed: 8908860

Links to Exploration step

pubmed:8908860

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Prosthesis misfit and marginal bone loss in edentulous implant patients.</title>
<author>
<name sortKey="Jemt, T" sort="Jemt, T" uniqKey="Jemt T" first="T" last="Jemt">T. Jemt</name>
<affiliation>
<nlm:affiliation>Brånemark Clinic, Public Dental Health, Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Book, K" sort="Book, K" uniqKey="Book K" first="K" last="Book">K. Book</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>1996 Sep-Oct</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:8908860</idno>
<idno type="pmid">8908860</idno>
<idno type="wicri:Area/PubMed/Corpus">003F98</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003F98</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Prosthesis misfit and marginal bone loss in edentulous implant patients.</title>
<author>
<name sortKey="Jemt, T" sort="Jemt, T" uniqKey="Jemt T" first="T" last="Jemt">T. Jemt</name>
<affiliation>
<nlm:affiliation>Brånemark Clinic, Public Dental Health, Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Book, K" sort="Book, K" uniqKey="Book K" first="K" last="Book">K. Book</name>
</author>
</analytic>
<series>
<title level="j">The International journal of oral & maxillofacial implants</title>
<idno type="ISSN">0882-2786</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adaptation, Physiological</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Bone Resorption (diagnostic imaging)</term>
<term>Bone Resorption (etiology)</term>
<term>Dental Implants (adverse effects)</term>
<term>Dental Prosthesis Design</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Male</term>
<term>Maxilla (diagnostic imaging)</term>
<term>Maxilla (surgery)</term>
<term>Maxillary Diseases (diagnostic imaging)</term>
<term>Maxillary Diseases (etiology)</term>
<term>Middle Aged</term>
<term>Osseointegration</term>
<term>Photogrammetry</term>
<term>Prospective Studies</term>
<term>Prosthesis Fitting</term>
<term>Radiography</term>
<term>Retrospective Studies</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="adverse effects" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Bone Resorption</term>
<term>Jaw, Edentulous</term>
<term>Maxilla</term>
<term>Maxillary Diseases</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Bone Resorption</term>
<term>Maxillary Diseases</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adaptation, Physiological</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Dental Prosthesis Design</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Osseointegration</term>
<term>Photogrammetry</term>
<term>Prospective Studies</term>
<term>Prosthesis Fitting</term>
<term>Radiography</term>
<term>Retrospective Studies</term>
<term>Surface Properties</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The objective of this study was to statistically correlate in vivo measurements of prosthesis misfit and change of marginal bone level in implants placed in the edentulous maxilla. Two groups, each comprising seven patients, were followed up either prospectively for 1 year or retrospectively for the last 4 years of the 5-year period after second-stage surgery. Measurements of prosthesis misfit were performed by means of a three-dimensional photogrammetric technique, and marginal bone levels were measured from standard intraoral radiographs. Results showed that none of the prostheses presented a completely passive fit to the implants in vivo. Furthermore, similar distortions of the prostheses were found in the two groups, indicating that the implants seemed to be stable and did not move, even after several years in function. The maximal range of three-dimensional distortion of cylinder center points was about 275 microns for both groups. Mean center point misfit was 111 (SD 59) and 91 (SD 51) microns for the 1-year and 5-year groups, respectively. The corresponding mean marginal bone loss was 0.5 and 0.2 mm for the two follow-up groups. No statistical correlations (P > .05) between change of marginal bone levels and different parameters of prosthesis misfit were observed in the two groups. The study indicated that a certain biologic tolerance for misfit may be present. The degree of misfit reported in the study was clinically acceptable with regard to observed marginal bone loss.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">8908860</PMID>
<DateCompleted>
<Year>1996</Year>
<Month>12</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0882-2786</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>11</Volume>
<Issue>5</Issue>
<PubDate>
<MedlineDate>1996 Sep-Oct</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of oral & maxillofacial implants</Title>
<ISOAbbreviation>Int J Oral Maxillofac Implants</ISOAbbreviation>
</Journal>
<ArticleTitle>Prosthesis misfit and marginal bone loss in edentulous implant patients.</ArticleTitle>
<Pagination>
<MedlinePgn>620-5</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The objective of this study was to statistically correlate in vivo measurements of prosthesis misfit and change of marginal bone level in implants placed in the edentulous maxilla. Two groups, each comprising seven patients, were followed up either prospectively for 1 year or retrospectively for the last 4 years of the 5-year period after second-stage surgery. Measurements of prosthesis misfit were performed by means of a three-dimensional photogrammetric technique, and marginal bone levels were measured from standard intraoral radiographs. Results showed that none of the prostheses presented a completely passive fit to the implants in vivo. Furthermore, similar distortions of the prostheses were found in the two groups, indicating that the implants seemed to be stable and did not move, even after several years in function. The maximal range of three-dimensional distortion of cylinder center points was about 275 microns for both groups. Mean center point misfit was 111 (SD 59) and 91 (SD 51) microns for the 1-year and 5-year groups, respectively. The corresponding mean marginal bone loss was 0.5 and 0.2 mm for the two follow-up groups. No statistical correlations (P > .05) between change of marginal bone levels and different parameters of prosthesis misfit were observed in the two groups. The study indicated that a certain biologic tolerance for misfit may be present. The degree of misfit reported in the study was clinically acceptable with regard to observed marginal bone loss.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Jemt</LastName>
<ForeName>T</ForeName>
<Initials>T</Initials>
<AffiliationInfo>
<Affiliation>Brånemark Clinic, Public Dental Health, Göteborg, Sweden.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Book</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Int J Oral Maxillofac Implants</MedlineTA>
<NlmUniqueID>8611905</NlmUniqueID>
<ISSNLinking>0882-2786</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000222" MajorTopicYN="N">Adaptation, Physiological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000369" MajorTopicYN="N">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001862" MajorTopicYN="N">Bone Resorption</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="Y">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="Y">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008439" MajorTopicYN="N">Maxillary Diseases</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="Y">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016348" MajorTopicYN="N">Osseointegration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010780" MajorTopicYN="N">Photogrammetry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011446" MajorTopicYN="N">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017755" MajorTopicYN="N">Prosthesis Fitting</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012189" MajorTopicYN="N">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1996</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1996</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1996</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8908860</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003F98 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 003F98 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:8908860
   |texte=   Prosthesis misfit and marginal bone loss in edentulous implant patients.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:8908860" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022