Fit of implant frameworks fabricated by different techniques.

Identifieur interne : 003C88 ( PubMed/Corpus ); précédent : 003C87; suivant : 003C89

Fit of implant frameworks fabricated by different techniques.

Auteurs : S J Riedy ; B R Lang ; B E Lang

Source :

RBID : pubmed:9421789

English descriptors

Abstract

This study evaluated the precision of fit between an implant framework and a patient simulation model that consisted of five implant abutments located in the mandibular symphysis area. One-piece cast frameworks were compared with Procera machined and laser-welded frameworks with laser videography.

PubMed: 9421789

Links to Exploration step

pubmed:9421789

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Fit of implant frameworks fabricated by different techniques.</title>
<author>
<name sortKey="Riedy, S J" sort="Riedy, S J" uniqKey="Riedy S" first="S J" last="Riedy">S J Riedy</name>
<affiliation>
<nlm:affiliation>Department of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lang, B R" sort="Lang, B R" uniqKey="Lang B" first="B R" last="Lang">B R Lang</name>
</author>
<author>
<name sortKey="Lang, B E" sort="Lang, B E" uniqKey="Lang B" first="B E" last="Lang">B E Lang</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1997">1997</date>
<idno type="RBID">pubmed:9421789</idno>
<idno type="pmid">9421789</idno>
<idno type="wicri:Area/PubMed/Corpus">003C88</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003C88</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Fit of implant frameworks fabricated by different techniques.</title>
<author>
<name sortKey="Riedy, S J" sort="Riedy, S J" uniqKey="Riedy S" first="S J" last="Riedy">S J Riedy</name>
<affiliation>
<nlm:affiliation>Department of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Lang, B R" sort="Lang, B R" uniqKey="Lang B" first="B R" last="Lang">B R Lang</name>
</author>
<author>
<name sortKey="Lang, B E" sort="Lang, B E" uniqKey="Lang B" first="B E" last="Lang">B E Lang</name>
</author>
</analytic>
<series>
<title level="j">The Journal of prosthetic dentistry</title>
<idno type="ISSN">0022-3913</idno>
<imprint>
<date when="1997" type="published">1997</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer Graphics</term>
<term>Dental Abutments</term>
<term>Dental Casting Technique</term>
<term>Dental Implants</term>
<term>Dental Models</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Soldering</term>
<term>Denture Bases</term>
<term>Denture Design (methods)</term>
<term>Evaluation Studies as Topic</term>
<term>Humans</term>
<term>Jaw, Edentulous</term>
<term>Laboratories, Dental</term>
<term>Lasers</term>
<term>Mandible</term>
<term>Surface Properties</term>
<term>Titanium</term>
<term>Video Recording</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Denture Design</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer Graphics</term>
<term>Dental Abutments</term>
<term>Dental Casting Technique</term>
<term>Dental Models</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Soldering</term>
<term>Denture Bases</term>
<term>Evaluation Studies as Topic</term>
<term>Humans</term>
<term>Jaw, Edentulous</term>
<term>Laboratories, Dental</term>
<term>Lasers</term>
<term>Mandible</term>
<term>Surface Properties</term>
<term>Video Recording</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This study evaluated the precision of fit between an implant framework and a patient simulation model that consisted of five implant abutments located in the mandibular symphysis area. One-piece cast frameworks were compared with Procera machined and laser-welded frameworks with laser videography.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">9421789</PMID>
<DateCompleted>
<Year>1998</Year>
<Month>02</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0022-3913</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>78</Volume>
<Issue>6</Issue>
<PubDate>
<Year>1997</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>The Journal of prosthetic dentistry</Title>
<ISOAbbreviation>J Prosthet Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Fit of implant frameworks fabricated by different techniques.</ArticleTitle>
<Pagination>
<MedlinePgn>596-604</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">This study evaluated the precision of fit between an implant framework and a patient simulation model that consisted of five implant abutments located in the mandibular symphysis area. One-piece cast frameworks were compared with Procera machined and laser-welded frameworks with laser videography.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">Five frameworks of each type were measured with a laser digitizer and a graphics computer program to determine a single point represented as the "Centroid" for each framework component and each implant abutment. Differences between the paired centroids for each framework/abutment interface are reported as x- and y-axis displacements, and z-axis gaps. The direction of the x- and y-axis displacements was determined.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There were significant differences (p < 0.05) in the precision of fit between both the one-piece cast frameworks and the Procera frameworks, when compared with the abutments in the patient simulation model. The laser-welded framework exhibited a more precise fit than the one-piece casting, with significant differences at four of the five prosthodontic interfaces, when evaluated by the mean z-axis gap at the centroid points.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Riedy</LastName>
<ForeName>S J</ForeName>
<Initials>SJ</Initials>
<AffiliationInfo>
<Affiliation>Department of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Lang</LastName>
<ForeName>B R</ForeName>
<Initials>BR</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lang</LastName>
<ForeName>B E</ForeName>
<Initials>BE</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Prosthet Dent</MedlineTA>
<NlmUniqueID>0376364</NlmUniqueID>
<ISSNLinking>0022-3913</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D003196" MajorTopicYN="N">Computer Graphics</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003735" MajorTopicYN="N">Dental Casting Technique</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012994" MajorTopicYN="N">Dental Soldering</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003819" MajorTopicYN="Y">Denture Bases</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005069" MajorTopicYN="N">Evaluation Studies as Topic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007754" MajorTopicYN="N">Laboratories, Dental</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007834" MajorTopicYN="N">Lasers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014741" MajorTopicYN="N">Video Recording</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1998</Year>
<Month>1</Month>
<Day>9</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1998</Year>
<Month>1</Month>
<Day>9</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1998</Year>
<Month>1</Month>
<Day>9</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">9421789</ArticleId>
<ArticleId IdType="pii">S0022-3913(97)70011-8</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003C88 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 003C88 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:9421789
   |texte=   Fit of implant frameworks fabricated by different techniques.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:9421789" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022