Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.

Identifieur interne : 003795 ( PubMed/Corpus ); précédent : 003794; suivant : 003796

A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.

Auteurs : Y. Sato ; N. Shindoi ; R. Hosokawa ; K. Tsuga ; Y. Akagawa

Source :

RBID : pubmed:10632839

English descriptors

Abstract

To prevent loosening or fracture of screws retaining the prosthesis to the implants in the posterior partially edentulous region, the use of staggered buccal and lingual offset placement or wide implants is suggested. However, it is not known how this usage compensates for the torque produced by lateral occlusal forces. This study evaluated the effectiveness of offset placement of three implants and a wide implant placement at the most posterior site. Three-dimensional geometric analysis was used to calculate the tensile force applied to gold screws in clinical situations with buccal or lingual loading perpendicular to cuspal inclination (10 or 20 degrees ). Four variations of the placement of three implants (3.75 mm) are: (1) straight; (2) buccal offset of the second implant; (3) lingual offset of the second implant; (4) a wide implant (5 mm) placement at most posterior site. The offset placement did not always decrease tensile force at the gold screw, but wide implant placement and decrease in cuspal inclination did.

PubMed: 10632839

Links to Exploration step

pubmed:10632839

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.</title>
<author>
<name sortKey="Sato, Y" sort="Sato, Y" uniqKey="Sato Y" first="Y" last="Sato">Y. Sato</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, Hiroshima University School of Dentistry, Hiroshima, Japan. sato@ipc.hiroshima-u.ac.jp</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Shindoi, N" sort="Shindoi, N" uniqKey="Shindoi N" first="N" last="Shindoi">N. Shindoi</name>
</author>
<author>
<name sortKey="Hosokawa, R" sort="Hosokawa, R" uniqKey="Hosokawa R" first="R" last="Hosokawa">R. Hosokawa</name>
</author>
<author>
<name sortKey="Tsuga, K" sort="Tsuga, K" uniqKey="Tsuga K" first="K" last="Tsuga">K. Tsuga</name>
</author>
<author>
<name sortKey="Akagawa, Y" sort="Akagawa, Y" uniqKey="Akagawa Y" first="Y" last="Akagawa">Y. Akagawa</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2000">2000</date>
<idno type="RBID">pubmed:10632839</idno>
<idno type="pmid">10632839</idno>
<idno type="wicri:Area/PubMed/Corpus">003795</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003795</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.</title>
<author>
<name sortKey="Sato, Y" sort="Sato, Y" uniqKey="Sato Y" first="Y" last="Sato">Y. Sato</name>
<affiliation>
<nlm:affiliation>Department of Removable Prosthodontics, Hiroshima University School of Dentistry, Hiroshima, Japan. sato@ipc.hiroshima-u.ac.jp</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Shindoi, N" sort="Shindoi, N" uniqKey="Shindoi N" first="N" last="Shindoi">N. Shindoi</name>
</author>
<author>
<name sortKey="Hosokawa, R" sort="Hosokawa, R" uniqKey="Hosokawa R" first="R" last="Hosokawa">R. Hosokawa</name>
</author>
<author>
<name sortKey="Tsuga, K" sort="Tsuga, K" uniqKey="Tsuga K" first="K" last="Tsuga">K. Tsuga</name>
</author>
<author>
<name sortKey="Akagawa, Y" sort="Akagawa, Y" uniqKey="Akagawa Y" first="Y" last="Akagawa">Y. Akagawa</name>
</author>
</analytic>
<series>
<title level="j">Journal of oral rehabilitation</title>
<idno type="ISSN">0305-182X</idno>
<imprint>
<date when="2000" type="published">2000</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Bicuspid</term>
<term>Biomechanical Phenomena</term>
<term>Dental Abutments (statistics & numerical data)</term>
<term>Dental Implantation, Endosseous (instrumentation)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implantation, Endosseous (statistics & numerical data)</term>
<term>Dental Prosthesis Design (methods)</term>
<term>Dental Prosthesis Design (statistics & numerical data)</term>
<term>Dental Prosthesis Retention (instrumentation)</term>
<term>Dental Prosthesis Retention (methods)</term>
<term>Dental Prosthesis Retention (statistics & numerical data)</term>
<term>Dental Stress Analysis (methods)</term>
<term>Dental Stress Analysis (statistics & numerical data)</term>
<term>Finite Element Analysis (statistics & numerical data)</term>
<term>Gold Alloys</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (physiopathology)</term>
<term>Jaw, Edentulous, Partially (rehabilitation)</term>
<term>Mandible</term>
<term>Molar</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Gold Alloys</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Retention</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis Retention</term>
<term>Dental Stress Analysis</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
</keywords>
<keywords scheme="MESH" qualifier="statistics & numerical data" xml:lang="en">
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis Retention</term>
<term>Dental Stress Analysis</term>
<term>Finite Element Analysis</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Bicuspid</term>
<term>Biomechanical Phenomena</term>
<term>Humans</term>
<term>Mandible</term>
<term>Molar</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To prevent loosening or fracture of screws retaining the prosthesis to the implants in the posterior partially edentulous region, the use of staggered buccal and lingual offset placement or wide implants is suggested. However, it is not known how this usage compensates for the torque produced by lateral occlusal forces. This study evaluated the effectiveness of offset placement of three implants and a wide implant placement at the most posterior site. Three-dimensional geometric analysis was used to calculate the tensile force applied to gold screws in clinical situations with buccal or lingual loading perpendicular to cuspal inclination (10 or 20 degrees ). Four variations of the placement of three implants (3.75 mm) are: (1) straight; (2) buccal offset of the second implant; (3) lingual offset of the second implant; (4) a wide implant (5 mm) placement at most posterior site. The offset placement did not always decrease tensile force at the gold screw, but wide implant placement and decrease in cuspal inclination did.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">10632839</PMID>
<DateCompleted>
<Year>2000</Year>
<Month>02</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0305-182X</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>27</Volume>
<Issue>1</Issue>
<PubDate>
<Year>2000</Year>
<Month>Jan</Month>
</PubDate>
</JournalIssue>
<Title>Journal of oral rehabilitation</Title>
<ISOAbbreviation>J Oral Rehabil</ISOAbbreviation>
</Journal>
<ArticleTitle>A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.</ArticleTitle>
<Pagination>
<MedlinePgn>15-21</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>To prevent loosening or fracture of screws retaining the prosthesis to the implants in the posterior partially edentulous region, the use of staggered buccal and lingual offset placement or wide implants is suggested. However, it is not known how this usage compensates for the torque produced by lateral occlusal forces. This study evaluated the effectiveness of offset placement of three implants and a wide implant placement at the most posterior site. Three-dimensional geometric analysis was used to calculate the tensile force applied to gold screws in clinical situations with buccal or lingual loading perpendicular to cuspal inclination (10 or 20 degrees ). Four variations of the placement of three implants (3.75 mm) are: (1) straight; (2) buccal offset of the second implant; (3) lingual offset of the second implant; (4) a wide implant (5 mm) placement at most posterior site. The offset placement did not always decrease tensile force at the gold screw, but wide implant placement and decrease in cuspal inclination did.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Sato</LastName>
<ForeName>Y</ForeName>
<Initials>Y</Initials>
<AffiliationInfo>
<Affiliation>Department of Removable Prosthodontics, Hiroshima University School of Dentistry, Hiroshima, Japan. sato@ipc.hiroshima-u.ac.jp</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Shindoi</LastName>
<ForeName>N</ForeName>
<Initials>N</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hosokawa</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Tsuga</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Akagawa</LastName>
<ForeName>Y</ForeName>
<Initials>Y</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>J Oral Rehabil</MedlineTA>
<NlmUniqueID>0433604</NlmUniqueID>
<ISSNLinking>0305-182X</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D006047">Gold Alloys</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D001641" MajorTopicYN="N">Bicuspid</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001696" MajorTopicYN="N">Biomechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017268" MajorTopicYN="N">Dental Prosthesis Retention</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003799" MajorTopicYN="N">Dental Stress Analysis</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D020342" MajorTopicYN="N">Finite Element Analysis</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006047" MajorTopicYN="N">Gold Alloys</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="Y">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008963" MajorTopicYN="N">Molar</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2000</Year>
<Month>1</Month>
<Day>13</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2000</Year>
<Month>2</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2000</Year>
<Month>1</Month>
<Day>13</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">10632839</ArticleId>
<ArticleId IdType="pii">jor475</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003795 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 003795 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:10632839
   |texte=   A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:10632839" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022