Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.

Identifieur interne : 003555 ( PubMed/Corpus ); précédent : 003554; suivant : 003556

Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.

Auteurs : K. Akça ; H. Iplikçio Lu

Source :

RBID : pubmed:11813664

English descriptors

Abstract

Buccolingual angulation of the mandibular posterior edentulous region may affect the prosthetic load conditions, so as to cause high stress concentrated areas that may easily lead to failure. The aim of this study was to evaluate the effect of various predetermined buccolingual angulation values on stress distribution in the mandibular posterior edentulous region restored with implant-supported fixed partial dentures, using three-dimensional finite element analysis. Stress analyses were performed applying 400N oblique force to implant-supported fixed prosthesis. Stress analyses indicated tensile stress values on the buccal surface and compressive stress values on the lingual surface of cortical bone were increased as the angulation of the edentulous bone increased (especially corresponding to the cervical region of the implants). Compressive stress values, observed where two implants were placed at the second premolar and second molar regions (5-7 design) and first and second molar regions (6-7 design), respectively, were very close to or even exceeded the ultimate compressive strength of bone. It is concluded that when a definite buccolingual angulation is added to other existing risk factors such as bruxism, placing an implant for every missing tooth might reduce the high stress concentration areas.

PubMed: 11813664

Links to Exploration step

pubmed:11813664

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.</title>
<author>
<name sortKey="Akca, K" sort="Akca, K" uniqKey="Akca K" first="K" last="Akça">K. Akça</name>
<affiliation>
<nlm:affiliation>Hacettepe University, Faculty of Dentistry, Department of Prosthodontics, 06100 Slhhiye Ankara, Turkey. kivanc.akca@veezy.com</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Iplikcio Lu, H" sort="Iplikcio Lu, H" uniqKey="Iplikcio Lu H" first="H" last="Iplikçio Lu">H. Iplikçio Lu</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2001">2001</date>
<idno type="RBID">pubmed:11813664</idno>
<idno type="pmid">11813664</idno>
<idno type="wicri:Area/PubMed/Corpus">003555</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">003555</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.</title>
<author>
<name sortKey="Akca, K" sort="Akca, K" uniqKey="Akca K" first="K" last="Akça">K. Akça</name>
<affiliation>
<nlm:affiliation>Hacettepe University, Faculty of Dentistry, Department of Prosthodontics, 06100 Slhhiye Ankara, Turkey. kivanc.akca@veezy.com</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Iplikcio Lu, H" sort="Iplikcio Lu, H" uniqKey="Iplikcio Lu H" first="H" last="Iplikçio Lu">H. Iplikçio Lu</name>
</author>
</analytic>
<series>
<title level="j">Implant dentistry</title>
<idno type="ISSN">1056-6163</idno>
<imprint>
<date when="2001" type="published">2001</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Bicuspid</term>
<term>Bite Force</term>
<term>Computer Simulation</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Denture Design</term>
<term>Denture, Partial, Fixed</term>
<term>Finite Element Analysis</term>
<term>Humans</term>
<term>Jaw, Edentulous, Partially (pathology)</term>
<term>Jaw, Edentulous, Partially (physiopathology)</term>
<term>Jaw, Edentulous, Partially (surgery)</term>
<term>Mandible (pathology)</term>
<term>Mandible (physiopathology)</term>
<term>Mandible (surgery)</term>
<term>Models, Biological</term>
<term>Molar</term>
<term>Stress, Mechanical</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Bicuspid</term>
<term>Bite Force</term>
<term>Computer Simulation</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Denture Design</term>
<term>Denture, Partial, Fixed</term>
<term>Finite Element Analysis</term>
<term>Humans</term>
<term>Models, Biological</term>
<term>Molar</term>
<term>Stress, Mechanical</term>
<term>Surface Properties</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Buccolingual angulation of the mandibular posterior edentulous region may affect the prosthetic load conditions, so as to cause high stress concentrated areas that may easily lead to failure. The aim of this study was to evaluate the effect of various predetermined buccolingual angulation values on stress distribution in the mandibular posterior edentulous region restored with implant-supported fixed partial dentures, using three-dimensional finite element analysis. Stress analyses were performed applying 400N oblique force to implant-supported fixed prosthesis. Stress analyses indicated tensile stress values on the buccal surface and compressive stress values on the lingual surface of cortical bone were increased as the angulation of the edentulous bone increased (especially corresponding to the cervical region of the implants). Compressive stress values, observed where two implants were placed at the second premolar and second molar regions (5-7 design) and first and second molar regions (6-7 design), respectively, were very close to or even exceeded the ultimate compressive strength of bone. It is concluded that when a definite buccolingual angulation is added to other existing risk factors such as bruxism, placing an implant for every missing tooth might reduce the high stress concentration areas.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">11813664</PMID>
<DateCompleted>
<Year>2002</Year>
<Month>02</Month>
<Day>21</Day>
</DateCompleted>
<DateRevised>
<Year>2004</Year>
<Month>11</Month>
<Day>17</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">1056-6163</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>10</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2001</Year>
</PubDate>
</JournalIssue>
<Title>Implant dentistry</Title>
<ISOAbbreviation>Implant Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.</ArticleTitle>
<Pagination>
<MedlinePgn>238-45</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Buccolingual angulation of the mandibular posterior edentulous region may affect the prosthetic load conditions, so as to cause high stress concentrated areas that may easily lead to failure. The aim of this study was to evaluate the effect of various predetermined buccolingual angulation values on stress distribution in the mandibular posterior edentulous region restored with implant-supported fixed partial dentures, using three-dimensional finite element analysis. Stress analyses were performed applying 400N oblique force to implant-supported fixed prosthesis. Stress analyses indicated tensile stress values on the buccal surface and compressive stress values on the lingual surface of cortical bone were increased as the angulation of the edentulous bone increased (especially corresponding to the cervical region of the implants). Compressive stress values, observed where two implants were placed at the second premolar and second molar regions (5-7 design) and first and second molar regions (6-7 design), respectively, were very close to or even exceeded the ultimate compressive strength of bone. It is concluded that when a definite buccolingual angulation is added to other existing risk factors such as bruxism, placing an implant for every missing tooth might reduce the high stress concentration areas.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Akça</LastName>
<ForeName>K</ForeName>
<Initials>K</Initials>
<AffiliationInfo>
<Affiliation>Hacettepe University, Faculty of Dentistry, Department of Prosthodontics, 06100 Slhhiye Ankara, Turkey. kivanc.akca@veezy.com</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Iplikçioğlu</LastName>
<ForeName>H</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Implant Dent</MedlineTA>
<NlmUniqueID>9206481</NlmUniqueID>
<ISSNLinking>1056-6163</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D001641" MajorTopicYN="N">Bicuspid</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001732" MajorTopicYN="N">Bite Force</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003198" MajorTopicYN="N">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="N">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003830" MajorTopicYN="Y">Denture, Partial, Fixed</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D020342" MajorTopicYN="Y">Finite Element Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008954" MajorTopicYN="N">Models, Biological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008963" MajorTopicYN="N">Molar</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013314" MajorTopicYN="N">Stress, Mechanical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2002</Year>
<Month>1</Month>
<Day>30</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2002</Year>
<Month>2</Month>
<Day>22</Day>
<Hour>10</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2002</Year>
<Month>1</Month>
<Day>30</Day>
<Hour>10</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">11813664</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003555 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 003555 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:11813664
   |texte=   Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:11813664" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022