Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.
Identifieur interne : 002F67 ( PubMed/Corpus ); précédent : 002F66; suivant : 002F68Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.
Auteurs : Anders Ortorp ; Torsten Jemt ; Tomas B Ck ; Tord J LevikSource :
- The International journal of prosthodontics [ 0893-2174 ]
English descriptors
- KwdEn :
- Acrylic Resins (chemistry), Computer-Aided Design, Dental Abutments, Dental Casting Investment (chemistry), Dental Casting Technique, Dental Implants, Dental Porcelain (chemistry), Dental Prosthesis, Implant-Supported, Dental Veneers, Denture Design, Gold Alloys (chemistry), Humans, Jaw, Edentulous (rehabilitation), Mandible, Reproducibility of Results, Surface Properties, Titanium (chemistry).
- MESH :
- chemical , chemistry : Acrylic Resins, Dental Casting Investment, Dental Porcelain, Gold Alloys, Titanium.
- rehabilitation : Jaw, Edentulous.
- Computer-Aided Design, Dental Abutments, Dental Casting Technique, Dental Implants, Dental Prosthesis, Implant-Supported, Dental Veneers, Denture Design, Humans, Mandible, Reproducibility of Results, Surface Properties.
Abstract
The purpose of this study was to investigate and compare the precision of fabrication in repeatqdly produced computer numeric controlled (CNC)-milled frameworks with consventional castings, and to analyze the distortion from application of different veneering materials.
PubMed: 12737254
Links to Exploration step
pubmed:12737254Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.</title>
<author><name sortKey="Ortorp, Anders" sort="Ortorp, Anders" uniqKey="Ortorp A" first="Anders" last="Ortorp">Anders Ortorp</name>
<affiliation><nlm:affiliation>The Brånemark Clinic, Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Jemt, Torsten" sort="Jemt, Torsten" uniqKey="Jemt T" first="Torsten" last="Jemt">Torsten Jemt</name>
</author>
<author><name sortKey="B Ck, Tomas" sort="B Ck, Tomas" uniqKey="B Ck T" first="Tomas" last="B Ck">Tomas B Ck</name>
</author>
<author><name sortKey="J Levik, Tord" sort="J Levik, Tord" uniqKey="J Levik T" first="Tord" last="J Levik">Tord J Levik</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2003 Mar-Apr</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:12737254</idno>
<idno type="pmid">12737254</idno>
<idno type="wicri:Area/PubMed/Corpus">002F67</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002F67</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.</title>
<author><name sortKey="Ortorp, Anders" sort="Ortorp, Anders" uniqKey="Ortorp A" first="Anders" last="Ortorp">Anders Ortorp</name>
<affiliation><nlm:affiliation>The Brånemark Clinic, Göteborg, Sweden.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Jemt, Torsten" sort="Jemt, Torsten" uniqKey="Jemt T" first="Torsten" last="Jemt">Torsten Jemt</name>
</author>
<author><name sortKey="B Ck, Tomas" sort="B Ck, Tomas" uniqKey="B Ck T" first="Tomas" last="B Ck">Tomas B Ck</name>
</author>
<author><name sortKey="J Levik, Tord" sort="J Levik, Tord" uniqKey="J Levik T" first="Tord" last="J Levik">Tord J Levik</name>
</author>
</analytic>
<series><title level="j">The International journal of prosthodontics</title>
<idno type="ISSN">0893-2174</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins (chemistry)</term>
<term>Computer-Aided Design</term>
<term>Dental Abutments</term>
<term>Dental Casting Investment (chemistry)</term>
<term>Dental Casting Technique</term>
<term>Dental Implants</term>
<term>Dental Porcelain (chemistry)</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Veneers</term>
<term>Denture Design</term>
<term>Gold Alloys (chemistry)</term>
<term>Humans</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Mandible</term>
<term>Reproducibility of Results</term>
<term>Surface Properties</term>
<term>Titanium (chemistry)</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en"><term>Acrylic Resins</term>
<term>Dental Casting Investment</term>
<term>Dental Porcelain</term>
<term>Gold Alloys</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Computer-Aided Design</term>
<term>Dental Abutments</term>
<term>Dental Casting Technique</term>
<term>Dental Implants</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Veneers</term>
<term>Denture Design</term>
<term>Humans</term>
<term>Mandible</term>
<term>Reproducibility of Results</term>
<term>Surface Properties</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The purpose of this study was to investigate and compare the precision of fabrication in repeatqdly produced computer numeric controlled (CNC)-milled frameworks with consventional castings, and to analyze the distortion from application of different veneering materials.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">12737254</PMID>
<DateCompleted><Year>2003</Year>
<Month>07</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised><Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0893-2174</ISSN>
<JournalIssue CitedMedium="Print"><Volume>16</Volume>
<Issue>2</Issue>
<PubDate><MedlineDate>2003 Mar-Apr</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of prosthodontics</Title>
<ISOAbbreviation>Int J Prosthodont</ISOAbbreviation>
</Journal>
<ArticleTitle>Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.</ArticleTitle>
<Pagination><MedlinePgn>194-200</MedlinePgn>
</Pagination>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The purpose of this study was to investigate and compare the precision of fabrication in repeatqdly produced computer numeric controlled (CNC)-milled frameworks with consventional castings, and to analyze the distortion from application of different veneering materials.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Twenty identical titanium frameworks were fabricated by means of a CNC milling technique for the same master model. Five conventional frameworks were cast as a control group to the same model. The frames were measured with regard to fit in a coordinate measuring machine linked to a computer. Measurements were made during different stages of handling of the titanium framework, and after veneering materials had been applied.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The CNC frameworks showed a statistically better fit and precision of fabrication compared to conventional castings (P < .05). The application of veneering material did not statistically affect the fit of the titanium frameworks (P > .05).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">It is possible to fabricate implant-supported frameworks by means of the present CNC technique with a very high precision and repeatability.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Ortorp</LastName>
<ForeName>Anders</ForeName>
<Initials>A</Initials>
<AffiliationInfo><Affiliation>The Brånemark Clinic, Göteborg, Sweden.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Jemt</LastName>
<ForeName>Torsten</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y"><LastName>Bäck</LastName>
<ForeName>Tomas</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y"><LastName>Jälevik</LastName>
<ForeName>Tord</ForeName>
<Initials>T</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Int J Prosthodont</MedlineTA>
<NlmUniqueID>8900938</NlmUniqueID>
<ISSNLinking>0893-2174</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003734">Dental Casting Investment</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D006047">Gold Alloys</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>12001-21-7</RegistryNumber>
<NameOfSubstance UI="D003776">Dental Porcelain</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017076" MajorTopicYN="Y">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003734" MajorTopicYN="N">Dental Casting Investment</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003735" MajorTopicYN="Y">Dental Casting Technique</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003776" MajorTopicYN="N">Dental Porcelain</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003801" MajorTopicYN="N">Dental Veneers</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003779" MajorTopicYN="Y">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006047" MajorTopicYN="N">Gold Alloys</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014025" MajorTopicYN="Y">Titanium</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="pubmed"><Year>2003</Year>
<Month>5</Month>
<Day>10</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2003</Year>
<Month>7</Month>
<Day>24</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2003</Year>
<Month>5</Month>
<Day>10</Day>
<Hour>5</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">12737254</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002F67 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002F67 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:12737254 |texte= Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:12737254" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |