Radiographic follow-up analysis of Brånemark dental implants.

Identifieur interne : 002297 ( PubMed/Corpus ); précédent : 002296; suivant : 002298

Radiographic follow-up analysis of Brånemark dental implants.

Auteurs : Solweig Sundén Pikner

Source :

RBID : pubmed:18652086

English descriptors

Abstract

Radiography plays an important role in clinical routine practice and in research projects evaluating dental implants, among them Brånemark System. Presence of a peri-implant radiolucency has been used in studies as a criterion for implant failure without knowledge of its diagnostic accuracy. More precise determination, whether implants are osseointegrated or not, can be achieved if prosthetic constructions are detached to test implant stability. Such an approach is time-consuming and cumbersome. Hence, the accuracy in radiographic diagnosis of clinical instability has to be evaluated. Further, radiography is a commonly used diagnostic tool for monitoring marginal bone loss. Little is known about the observer variation. Long-term follow-up studies have shown conventional implant therapy to be a reliable procedure with few complications and minor average bone loss. Lately, studies have shown progressive bone loss in higher frequencies. When testing accuracy in diagnosis of clinical instability in intra-oral radiographs, it was found to be as good as of many other radiographic procedures, e.g. caries diagnosis. Possibility of predicting instability, however, can be low in populations with low prevalence of implants showing loss of osseointegration. Intra-observer variation was found to be the largest source of the total variation when studying inter- and intra-observer variability in radiographic bone level assessments. The number of radiographs in which individual implants were displayed had an influenced on intra-observer variation, while radiographic density and increased bone loss influenced the total inter-observer variation. Reliability can be improved by multiple readings by one observer or, even better, by letting several observers make several, independent readings, this limits the effect of a single observer who may be an outlier. Marginal bone level was assessed in 640 patients with a radiographic follow-up of > or = 5 years. The number of implants with a mean bone level of > or = 3 mm below the fixture-abutment connection increased from 2.8% at prosthesis insertion to 17.2% after 15 years. Implant-based bone loss was as a mean 0.8 mm (SD 0.8) after 5 years, followed by only minor average changes. Mean bone loss on patient level followed a similar pattern. Disregarding of follow-up time, altogether 183 implants showed a bone loss > or = 3 mm from prosthesis insertion to last examination, most of them in totally edentulous patients. Seventy of the 183 implants were found in 19 of the 107 patients. Hence, there seems to be a clustering effect. For the entire group of patients significantly larger bone loss was found the older the patient was at surgery and for lower jaw implants. Placement of the implant within the prosthetic construction, regardless of jaw-type, was found to be a predictor of a bone loss > or = 2 mm with minor bone loss around implants placed in an end position. Other predictors were age and jaw-type. The number of intra-oral radiographs per examination, and more importantly, radiographic examinations can be reduced without jeopardizing good clinical management, a statement valid also for Brånemark implants with advanced bone loss. To conclude, conventional implant treatment can still be regarded as a reliable and safe procedure.

PubMed: 18652086

Links to Exploration step

pubmed:18652086

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Radiographic follow-up analysis of Brånemark dental implants.</title>
<author>
<name sortKey="Pikner, Solweig Sunden" sort="Pikner, Solweig Sunden" uniqKey="Pikner S" first="Solweig Sundén" last="Pikner">Solweig Sundén Pikner</name>
<affiliation>
<nlm:affiliation>Department of Oral and Maxillofacial Radiology, Institute of Odontology, University of Gothenburg. solweig.sunden.pikner@orebroll.se</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="RBID">pubmed:18652086</idno>
<idno type="pmid">18652086</idno>
<idno type="wicri:Area/PubMed/Corpus">002297</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">002297</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Radiographic follow-up analysis of Brånemark dental implants.</title>
<author>
<name sortKey="Pikner, Solweig Sunden" sort="Pikner, Solweig Sunden" uniqKey="Pikner S" first="Solweig Sundén" last="Pikner">Solweig Sundén Pikner</name>
<affiliation>
<nlm:affiliation>Department of Oral and Maxillofacial Radiology, Institute of Odontology, University of Gothenburg. solweig.sunden.pikner@orebroll.se</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Swedish dental journal. Supplement</title>
<idno type="ISSN">0348-6672</idno>
<imprint>
<date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Alveolar Bone Loss (diagnostic imaging)</term>
<term>Alveolar Bone Loss (etiology)</term>
<term>Dental Implantation, Endosseous (adverse effects)</term>
<term>Dental Implants (adverse effects)</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Observer Variation</term>
<term>Osseointegration</term>
<term>Radiography</term>
<term>Reproducibility of Results</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="adverse effects" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Alveolar Bone Loss</term>
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Alveolar Bone Loss</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Dental Restoration Failure</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Observer Variation</term>
<term>Osseointegration</term>
<term>Radiography</term>
<term>Reproducibility of Results</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Radiography plays an important role in clinical routine practice and in research projects evaluating dental implants, among them Brånemark System. Presence of a peri-implant radiolucency has been used in studies as a criterion for implant failure without knowledge of its diagnostic accuracy. More precise determination, whether implants are osseointegrated or not, can be achieved if prosthetic constructions are detached to test implant stability. Such an approach is time-consuming and cumbersome. Hence, the accuracy in radiographic diagnosis of clinical instability has to be evaluated. Further, radiography is a commonly used diagnostic tool for monitoring marginal bone loss. Little is known about the observer variation. Long-term follow-up studies have shown conventional implant therapy to be a reliable procedure with few complications and minor average bone loss. Lately, studies have shown progressive bone loss in higher frequencies. When testing accuracy in diagnosis of clinical instability in intra-oral radiographs, it was found to be as good as of many other radiographic procedures, e.g. caries diagnosis. Possibility of predicting instability, however, can be low in populations with low prevalence of implants showing loss of osseointegration. Intra-observer variation was found to be the largest source of the total variation when studying inter- and intra-observer variability in radiographic bone level assessments. The number of radiographs in which individual implants were displayed had an influenced on intra-observer variation, while radiographic density and increased bone loss influenced the total inter-observer variation. Reliability can be improved by multiple readings by one observer or, even better, by letting several observers make several, independent readings, this limits the effect of a single observer who may be an outlier. Marginal bone level was assessed in 640 patients with a radiographic follow-up of > or = 5 years. The number of implants with a mean bone level of > or = 3 mm below the fixture-abutment connection increased from 2.8% at prosthesis insertion to 17.2% after 15 years. Implant-based bone loss was as a mean 0.8 mm (SD 0.8) after 5 years, followed by only minor average changes. Mean bone loss on patient level followed a similar pattern. Disregarding of follow-up time, altogether 183 implants showed a bone loss > or = 3 mm from prosthesis insertion to last examination, most of them in totally edentulous patients. Seventy of the 183 implants were found in 19 of the 107 patients. Hence, there seems to be a clustering effect. For the entire group of patients significantly larger bone loss was found the older the patient was at surgery and for lower jaw implants. Placement of the implant within the prosthetic construction, regardless of jaw-type, was found to be a predictor of a bone loss > or = 2 mm with minor bone loss around implants placed in an end position. Other predictors were age and jaw-type. The number of intra-oral radiographs per examination, and more importantly, radiographic examinations can be reduced without jeopardizing good clinical management, a statement valid also for Brånemark implants with advanced bone loss. To conclude, conventional implant treatment can still be regarded as a reliable and safe procedure.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">18652086</PMID>
<DateCompleted>
<Year>2008</Year>
<Month>07</Month>
<Day>31</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>24</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0348-6672</ISSN>
<JournalIssue CitedMedium="Print">
<Issue>194</Issue>
<PubDate>
<Year>2008</Year>
</PubDate>
</JournalIssue>
<Title>Swedish dental journal. Supplement</Title>
<ISOAbbreviation>Swed Dent J Suppl</ISOAbbreviation>
</Journal>
<ArticleTitle>Radiographic follow-up analysis of Brånemark dental implants.</ArticleTitle>
<Pagination>
<MedlinePgn>5-69, 2</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Radiography plays an important role in clinical routine practice and in research projects evaluating dental implants, among them Brånemark System. Presence of a peri-implant radiolucency has been used in studies as a criterion for implant failure without knowledge of its diagnostic accuracy. More precise determination, whether implants are osseointegrated or not, can be achieved if prosthetic constructions are detached to test implant stability. Such an approach is time-consuming and cumbersome. Hence, the accuracy in radiographic diagnosis of clinical instability has to be evaluated. Further, radiography is a commonly used diagnostic tool for monitoring marginal bone loss. Little is known about the observer variation. Long-term follow-up studies have shown conventional implant therapy to be a reliable procedure with few complications and minor average bone loss. Lately, studies have shown progressive bone loss in higher frequencies. When testing accuracy in diagnosis of clinical instability in intra-oral radiographs, it was found to be as good as of many other radiographic procedures, e.g. caries diagnosis. Possibility of predicting instability, however, can be low in populations with low prevalence of implants showing loss of osseointegration. Intra-observer variation was found to be the largest source of the total variation when studying inter- and intra-observer variability in radiographic bone level assessments. The number of radiographs in which individual implants were displayed had an influenced on intra-observer variation, while radiographic density and increased bone loss influenced the total inter-observer variation. Reliability can be improved by multiple readings by one observer or, even better, by letting several observers make several, independent readings, this limits the effect of a single observer who may be an outlier. Marginal bone level was assessed in 640 patients with a radiographic follow-up of > or = 5 years. The number of implants with a mean bone level of > or = 3 mm below the fixture-abutment connection increased from 2.8% at prosthesis insertion to 17.2% after 15 years. Implant-based bone loss was as a mean 0.8 mm (SD 0.8) after 5 years, followed by only minor average changes. Mean bone loss on patient level followed a similar pattern. Disregarding of follow-up time, altogether 183 implants showed a bone loss > or = 3 mm from prosthesis insertion to last examination, most of them in totally edentulous patients. Seventy of the 183 implants were found in 19 of the 107 patients. Hence, there seems to be a clustering effect. For the entire group of patients significantly larger bone loss was found the older the patient was at surgery and for lower jaw implants. Placement of the implant within the prosthetic construction, regardless of jaw-type, was found to be a predictor of a bone loss > or = 2 mm with minor bone loss around implants placed in an end position. Other predictors were age and jaw-type. The number of intra-oral radiographs per examination, and more importantly, radiographic examinations can be reduced without jeopardizing good clinical management, a statement valid also for Brånemark implants with advanced bone loss. To conclude, conventional implant treatment can still be regarded as a reliable and safe procedure.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Pikner</LastName>
<ForeName>Solweig Sundén</ForeName>
<Initials>SS</Initials>
<AffiliationInfo>
<Affiliation>Department of Oral and Maxillofacial Radiology, Institute of Odontology, University of Gothenburg. solweig.sunden.pikner@orebroll.se</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Sweden</Country>
<MedlineTA>Swed Dent J Suppl</MedlineTA>
<NlmUniqueID>7905899</NlmUniqueID>
<ISSNLinking>0348-6672</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016301" MajorTopicYN="N">Alveolar Bone Loss</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
<QualifierName UI="Q000209" MajorTopicYN="N">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="N">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="N">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005500" MajorTopicYN="N">Follow-Up Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015588" MajorTopicYN="N">Observer Variation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016348" MajorTopicYN="N">Osseointegration</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016896" MajorTopicYN="N">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2008</Year>
<Month>7</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>8</Month>
<Day>1</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2008</Year>
<Month>7</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">18652086</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002297 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 002297 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:18652086
   |texte=   Radiographic follow-up analysis of Brånemark dental implants.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:18652086" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022