Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.

Identifieur interne : 001F96 ( PubMed/Corpus ); précédent : 001F95; suivant : 001F97

Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.

Auteurs : Loong Tee Yong ; Peter K. Moy

Source :

RBID : pubmed:18241215

English descriptors

Abstract

The aim of this study was to evaluate early clinical results of computer-aided design (CAD)/computer-aided machining (CAM)-guided surgical implant placement (NobelGuide, Nobel Biocare, Yorba Linda, CA, USA) with focus on surgical and/or prosthetic complications, management, and prevention.

DOI: 10.1111/j.1708-8208.2007.00082.x
PubMed: 18241215

Links to Exploration step

pubmed:18241215

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.</title>
<author>
<name sortKey="Yong, Loong Tee" sort="Yong, Loong Tee" uniqKey="Yong L" first="Loong Tee" last="Yong">Loong Tee Yong</name>
<affiliation>
<nlm:affiliation>Oral and Maxillofacial Surgery, UCLA, USA. yongloongtee@yahoo.com.sg</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Moy, Peter K" sort="Moy, Peter K" uniqKey="Moy P" first="Peter K" last="Moy">Peter K. Moy</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2008">2008</date>
<idno type="RBID">pubmed:18241215</idno>
<idno type="pmid">18241215</idno>
<idno type="doi">10.1111/j.1708-8208.2007.00082.x</idno>
<idno type="wicri:Area/PubMed/Corpus">001F96</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001F96</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.</title>
<author>
<name sortKey="Yong, Loong Tee" sort="Yong, Loong Tee" uniqKey="Yong L" first="Loong Tee" last="Yong">Loong Tee Yong</name>
<affiliation>
<nlm:affiliation>Oral and Maxillofacial Surgery, UCLA, USA. yongloongtee@yahoo.com.sg</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Moy, Peter K" sort="Moy, Peter K" uniqKey="Moy P" first="Peter K" last="Moy">Peter K. Moy</name>
</author>
</analytic>
<series>
<title level="j">Clinical implant dentistry and related research</title>
<idno type="eISSN">1708-8208</idno>
<imprint>
<date when="2008" type="published">2008</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (adverse effects)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design (adverse effects)</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted</term>
<term>Time Factors</term>
<term>Weight-Bearing</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis Design</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Dental Restoration Failure</term>
<term>Humans</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted</term>
<term>Time Factors</term>
<term>Weight-Bearing</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to evaluate early clinical results of computer-aided design (CAD)/computer-aided machining (CAM)-guided surgical implant placement (NobelGuide, Nobel Biocare, Yorba Linda, CA, USA) with focus on surgical and/or prosthetic complications, management, and prevention.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">18241215</PMID>
<DateCompleted>
<Year>2008</Year>
<Month>11</Month>
<Day>17</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>24</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1708-8208</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>10</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2008</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>Clinical implant dentistry and related research</Title>
<ISOAbbreviation>Clin Implant Dent Relat Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.</ArticleTitle>
<Pagination>
<MedlinePgn>123-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/j.1708-8208.2007.00082.x</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The aim of this study was to evaluate early clinical results of computer-aided design (CAD)/computer-aided machining (CAM)-guided surgical implant placement (NobelGuide, Nobel Biocare, Yorba Linda, CA, USA) with focus on surgical and/or prosthetic complications, management, and prevention.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Thirteen patients rehabilitated between March 2003 and October 2006 with CAD/CAM-guided dental implants and immediate loading (NobelGuide, Nobel Biocare) were evaluated. The treatment planning and procedures were carried out in accordance to the system protocol. The complications encountered in this case series were classified and assessed according to early (planning and procedural - surgical; prosthetic) and late complications (surgical; prosthetic).</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The prosthetic complications outnumbered surgical complications both in the early and late treatment phases. The main early surgical complication was bony interference that prevented complete seating of the prostheses. Most of the late surgical complications were implant failures with an overall failure rate of 9%. Fracture of the carbon fiber framework prosthesis was the main late prosthetic complication.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">The NobelGuide system is a reliable treatment modality, but not without its complications. Strict adherence to the system protocol is the key prevention of complications.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Yong</LastName>
<ForeName>Loong Tee</ForeName>
<Initials>LT</Initials>
<AffiliationInfo>
<Affiliation>Oral and Maxillofacial Surgery, UCLA, USA. yongloongtee@yahoo.com.sg</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Moy</LastName>
<ForeName>Peter K</ForeName>
<Initials>PK</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2008</Year>
<Month>01</Month>
<Day>30</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Clin Implant Dent Relat Res</MedlineTA>
<NlmUniqueID>100888977</NlmUniqueID>
<ISSNLinking>1523-0899</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="Y">adverse effects</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
<QualifierName UI="Q000009" MajorTopicYN="Y">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="Y">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013997" MajorTopicYN="N">Time Factors</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D016474" MajorTopicYN="N">Weight-Bearing</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2008</Year>
<Month>2</Month>
<Day>5</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2008</Year>
<Month>11</Month>
<Day>18</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2008</Year>
<Month>2</Month>
<Day>5</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">18241215</ArticleId>
<ArticleId IdType="pii">CID082</ArticleId>
<ArticleId IdType="doi">10.1111/j.1708-8208.2007.00082.x</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001F96 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001F96 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:18241215
   |texte=   Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:18241215" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022