Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points.
Identifieur interne : 001974 ( PubMed/Corpus ); précédent : 001973; suivant : 001975Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points.
Auteurs : Gerlig Widmann ; Martin Keiler ; Antoniette Zangerl ; Rudolf Stoffner ; Stefano Longato ; Reto Bale ; Wolfgang PuelacherSource :
- Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons [ 1531-5053 ] ; 2010.
English descriptors
- KwdEn :
- Bone Screws, Cadaver, Dental Arch (surgery), Dental Implantation, Endosseous (instrumentation), Dental Implantation, Endosseous (methods), Dental Models, Humans, Image Processing, Computer-Assisted (methods), Jaw Relation Record (instrumentation), Jaw, Edentulous (surgery), Mandible (surgery), Maxilla (surgery), Patient Care Planning, Resins, Synthetic, Surgery, Computer-Assisted (instrumentation), Surgery, Computer-Assisted (methods), Tomography, X-Ray Computed, User-Computer Interface.
- MESH :
- chemical : Resins, Synthetic.
- instrumentation : Dental Implantation, Endosseous, Jaw Relation Record, Surgery, Computer-Assisted.
- methods : Dental Implantation, Endosseous, Image Processing, Computer-Assisted, Surgery, Computer-Assisted.
- surgery : Dental Arch, Jaw, Edentulous, Mandible, Maxilla.
- Bone Screws, Cadaver, Dental Models, Humans, Patient Care Planning, Tomography, X-Ray Computed, User-Computer Interface.
Abstract
In computer-assisted implantation surgery, the transfer of prosthodontic-guided planning to the operative site is usually based on a registration template. The precise repositioning of the registration template is crucial for high accuracy and is compromised in edentulous jaws. The purpose was to determine the in vitro registration and targeting accuracy for surgical navigation in the edentulous jaw based on 3 fixed intraoral reference points.
DOI: 10.1016/j.joms.2009.10.008
PubMed: 20156663
Links to Exploration step
pubmed:20156663Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points.</title>
<author><name sortKey="Widmann, Gerlig" sort="Widmann, Gerlig" uniqKey="Widmann G" first="Gerlig" last="Widmann">Gerlig Widmann</name>
<affiliation><nlm:affiliation>Stereotaxy Intervention Planning, Department for Microinvasive Therapy, Department of Radiology, Innsbruck Medical University, Innsbruck, Austria. gerlig.widmann@i-med.ac.at</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Keiler, Martin" sort="Keiler, Martin" uniqKey="Keiler M" first="Martin" last="Keiler">Martin Keiler</name>
</author>
<author><name sortKey="Zangerl, Antoniette" sort="Zangerl, Antoniette" uniqKey="Zangerl A" first="Antoniette" last="Zangerl">Antoniette Zangerl</name>
</author>
<author><name sortKey="Stoffner, Rudolf" sort="Stoffner, Rudolf" uniqKey="Stoffner R" first="Rudolf" last="Stoffner">Rudolf Stoffner</name>
</author>
<author><name sortKey="Longato, Stefano" sort="Longato, Stefano" uniqKey="Longato S" first="Stefano" last="Longato">Stefano Longato</name>
</author>
<author><name sortKey="Bale, Reto" sort="Bale, Reto" uniqKey="Bale R" first="Reto" last="Bale">Reto Bale</name>
</author>
<author><name sortKey="Puelacher, Wolfgang" sort="Puelacher, Wolfgang" uniqKey="Puelacher W" first="Wolfgang" last="Puelacher">Wolfgang Puelacher</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="RBID">pubmed:20156663</idno>
<idno type="pmid">20156663</idno>
<idno type="doi">10.1016/j.joms.2009.10.008</idno>
<idno type="wicri:Area/PubMed/Corpus">001974</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001974</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points.</title>
<author><name sortKey="Widmann, Gerlig" sort="Widmann, Gerlig" uniqKey="Widmann G" first="Gerlig" last="Widmann">Gerlig Widmann</name>
<affiliation><nlm:affiliation>Stereotaxy Intervention Planning, Department for Microinvasive Therapy, Department of Radiology, Innsbruck Medical University, Innsbruck, Austria. gerlig.widmann@i-med.ac.at</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Keiler, Martin" sort="Keiler, Martin" uniqKey="Keiler M" first="Martin" last="Keiler">Martin Keiler</name>
</author>
<author><name sortKey="Zangerl, Antoniette" sort="Zangerl, Antoniette" uniqKey="Zangerl A" first="Antoniette" last="Zangerl">Antoniette Zangerl</name>
</author>
<author><name sortKey="Stoffner, Rudolf" sort="Stoffner, Rudolf" uniqKey="Stoffner R" first="Rudolf" last="Stoffner">Rudolf Stoffner</name>
</author>
<author><name sortKey="Longato, Stefano" sort="Longato, Stefano" uniqKey="Longato S" first="Stefano" last="Longato">Stefano Longato</name>
</author>
<author><name sortKey="Bale, Reto" sort="Bale, Reto" uniqKey="Bale R" first="Reto" last="Bale">Reto Bale</name>
</author>
<author><name sortKey="Puelacher, Wolfgang" sort="Puelacher, Wolfgang" uniqKey="Puelacher W" first="Wolfgang" last="Puelacher">Wolfgang Puelacher</name>
</author>
</analytic>
<series><title level="j">Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons</title>
<idno type="eISSN">1531-5053</idno>
<imprint><date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Bone Screws</term>
<term>Cadaver</term>
<term>Dental Arch (surgery)</term>
<term>Dental Implantation, Endosseous (instrumentation)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Models</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted (methods)</term>
<term>Jaw Relation Record (instrumentation)</term>
<term>Jaw, Edentulous (surgery)</term>
<term>Mandible (surgery)</term>
<term>Maxilla (surgery)</term>
<term>Patient Care Planning</term>
<term>Resins, Synthetic</term>
<term>Surgery, Computer-Assisted (instrumentation)</term>
<term>Surgery, Computer-Assisted (methods)</term>
<term>Tomography, X-Ray Computed</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Resins, Synthetic</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Jaw Relation Record</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Image Processing, Computer-Assisted</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Dental Arch</term>
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Bone Screws</term>
<term>Cadaver</term>
<term>Dental Models</term>
<term>Humans</term>
<term>Patient Care Planning</term>
<term>Tomography, X-Ray Computed</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">In computer-assisted implantation surgery, the transfer of prosthodontic-guided planning to the operative site is usually based on a registration template. The precise repositioning of the registration template is crucial for high accuracy and is compromised in edentulous jaws. The purpose was to determine the in vitro registration and targeting accuracy for surgical navigation in the edentulous jaw based on 3 fixed intraoral reference points.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">20156663</PMID>
<DateCompleted><Year>2010</Year>
<Month>05</Month>
<Day>04</Day>
</DateCompleted>
<DateRevised><Year>2010</Year>
<Month>04</Month>
<Day>20</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1531-5053</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>68</Volume>
<Issue>5</Issue>
<PubDate><Year>2010</Year>
<Month>May</Month>
</PubDate>
</JournalIssue>
<Title>Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons</Title>
<ISOAbbreviation>J. Oral Maxillofac. Surg.</ISOAbbreviation>
</Journal>
<ArticleTitle>Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points.</ArticleTitle>
<Pagination><MedlinePgn>1140-7</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.joms.2009.10.008</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">In computer-assisted implantation surgery, the transfer of prosthodontic-guided planning to the operative site is usually based on a registration template. The precise repositioning of the registration template is crucial for high accuracy and is compromised in edentulous jaws. The purpose was to determine the in vitro registration and targeting accuracy for surgical navigation in the edentulous jaw based on 3 fixed intraoral reference points.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">Edentulous maxilla and mandible cadaver specimens were provided with 3 fixed reference-point screws. A resin template with matrices for the fixed reference-point screws was produced and connected to a Vogele-Bale-Hohner registration mouthpiece and external registration frame with a snap-lock system. Surgical implants were planned on computed tomographic data and the corresponding dental stone casts were drilled under guidance of an optical navigation system. For evaluation of the registration accuracy, fiducial registration error was recorded and application accuracy was evaluated by fusion of postsurgical computed tomographic scans of the drilled dental stone casts with the presurgical planning computed tomogram.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In 9 maxillas and 5 mandibles, 14 registrations and 104 stone cast drillings were performed. The mean fiducial registration error was 0.49 +/- 0.14 mm (0.37 to 0.9 mm). The mean total error at the tip of the borehole was 0.88 +/- 0.65 mm (0.0 to 4.24 mm). The mean lateral errors were 0.51 +/- 0.49 mm (0.0 to 2.80 mm) at the base and 0.46 +/- 0.34 mm (0.0 to 1.5 mm) at the tip of the borehole, respectively. The mean angular error was 0.83 +/- 0.60 degrees (0.0 to 2.5 degrees ).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Three fixed intraoral reference points successfully support a registration mouthpiece and provide in vitro registration and targeting accuracy that is comparable to tooth-supported registration templates or bone marker registration.</AbstractText>
<CopyrightInformation>Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Widmann</LastName>
<ForeName>Gerlig</ForeName>
<Initials>G</Initials>
<AffiliationInfo><Affiliation>Stereotaxy Intervention Planning, Department for Microinvasive Therapy, Department of Radiology, Innsbruck Medical University, Innsbruck, Austria. gerlig.widmann@i-med.ac.at</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Keiler</LastName>
<ForeName>Martin</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y"><LastName>Zangerl</LastName>
<ForeName>Antoniette</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y"><LastName>Stoffner</LastName>
<ForeName>Rudolf</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y"><LastName>Longato</LastName>
<ForeName>Stefano</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y"><LastName>Bale</LastName>
<ForeName>Reto</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y"><LastName>Puelacher</LastName>
<ForeName>Wolfgang</ForeName>
<Initials>W</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2010</Year>
<Month>02</Month>
<Day>13</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>J Oral Maxillofac Surg</MedlineTA>
<NlmUniqueID>8206428</NlmUniqueID>
<ISSNLinking>0278-2391</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012117">Resins, Synthetic</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>AIM</CitationSubset>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D001863" MajorTopicYN="N">Bone Screws</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D002102" MajorTopicYN="N">Cadaver</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003724" MajorTopicYN="N">Dental Arch</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007091" MajorTopicYN="N">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007574" MajorTopicYN="N">Jaw Relation Record</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012117" MajorTopicYN="N">Resins, Synthetic</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D025321" MajorTopicYN="Y">Surgery, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014057" MajorTopicYN="N">Tomography, X-Ray Computed</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014584" MajorTopicYN="N">User-Computer Interface</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2009</Year>
<Month>08</Month>
<Day>25</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2009</Year>
<Month>10</Month>
<Day>01</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2009</Year>
<Month>10</Month>
<Day>03</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2010</Year>
<Month>2</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2010</Year>
<Month>2</Month>
<Day>17</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2010</Year>
<Month>5</Month>
<Day>5</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">20156663</ArticleId>
<ArticleId IdType="pii">S0278-2391(09)01938-7</ArticleId>
<ArticleId IdType="doi">10.1016/j.joms.2009.10.008</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001974 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001974 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:20156663 |texte= Computer-assisted surgery in the edentulous jaw based on 3 fixed intraoral reference points. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:20156663" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2