Correction of nonparallel implants for an implant-retained overdenture.
Identifieur interne : 001891 ( PubMed/Corpus ); précédent : 001890; suivant : 001892Correction of nonparallel implants for an implant-retained overdenture.
Auteurs : Daniel Becker Nunes ; Paulo Da Silva ; Tatiana Pereira-Cenci ; Cezar Augusto Garbin ; Cristian Schuh ; Noeli BoscatoSource :
- General dentistry [ 0363-6771 ]
English descriptors
- KwdEn :
- Adult, Dental Abutments, Dental Implantation, Endosseous (instrumentation), Dental Implantation, Endosseous (methods), Dental Implants, Dental Prosthesis Design, Dental Prosthesis, Implant-Supported (instrumentation), Denture Retention, Denture, Complete, Lower, Denture, Overlay, Humans, Jaw, Edentulous (rehabilitation), Male, Mandible, Treatment Outcome.
- MESH :
- chemical : Dental Implants.
- instrumentation : Dental Implantation, Endosseous, Dental Prosthesis, Implant-Supported.
- methods : Dental Implantation, Endosseous.
- rehabilitation : Jaw, Edentulous.
- Adult, Dental Abutments, Dental Prosthesis Design, Denture Retention, Denture, Complete, Lower, Denture, Overlay, Humans, Male, Mandible, Treatment Outcome.
Abstract
An implant-retained overdenture is less expensive than a fixed implant-retained prosthesis; however, using ball attachments on abutments that are nonparallel and/or outside the path of insertion may result in loss of retention. As described in this case report, alignment devices can be used as a mandibular overdenture retainer to diminish the lack of parallelism between two implants. The treatment plan involved the use of an alignment device on each implant to ensure correct alignment among ball attachments and its retentive component. These devices can be used to fabricate overdentures retained by implants that are misaligned by as much as 14 degrees.
PubMed: 20591765
Links to Exploration step
pubmed:20591765Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Correction of nonparallel implants for an implant-retained overdenture.</title>
<author><name sortKey="Nunes, Daniel Becker" sort="Nunes, Daniel Becker" uniqKey="Nunes D" first="Daniel Becker" last="Nunes">Daniel Becker Nunes</name>
<affiliation><nlm:affiliation>Department of Prosthodontics, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Da Silva, Paulo" sort="Da Silva, Paulo" uniqKey="Da Silva P" first="Paulo" last="Da Silva">Paulo Da Silva</name>
</author>
<author><name sortKey="Pereira Cenci, Tatiana" sort="Pereira Cenci, Tatiana" uniqKey="Pereira Cenci T" first="Tatiana" last="Pereira-Cenci">Tatiana Pereira-Cenci</name>
</author>
<author><name sortKey="Garbin, Cezar Augusto" sort="Garbin, Cezar Augusto" uniqKey="Garbin C" first="Cezar Augusto" last="Garbin">Cezar Augusto Garbin</name>
</author>
<author><name sortKey="Schuh, Cristian" sort="Schuh, Cristian" uniqKey="Schuh C" first="Cristian" last="Schuh">Cristian Schuh</name>
</author>
<author><name sortKey="Boscato, Noeli" sort="Boscato, Noeli" uniqKey="Boscato N" first="Noeli" last="Boscato">Noeli Boscato</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2010 Jul-Aug</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:20591765</idno>
<idno type="pmid">20591765</idno>
<idno type="wicri:Area/PubMed/Corpus">001891</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001891</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Correction of nonparallel implants for an implant-retained overdenture.</title>
<author><name sortKey="Nunes, Daniel Becker" sort="Nunes, Daniel Becker" uniqKey="Nunes D" first="Daniel Becker" last="Nunes">Daniel Becker Nunes</name>
<affiliation><nlm:affiliation>Department of Prosthodontics, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Da Silva, Paulo" sort="Da Silva, Paulo" uniqKey="Da Silva P" first="Paulo" last="Da Silva">Paulo Da Silva</name>
</author>
<author><name sortKey="Pereira Cenci, Tatiana" sort="Pereira Cenci, Tatiana" uniqKey="Pereira Cenci T" first="Tatiana" last="Pereira-Cenci">Tatiana Pereira-Cenci</name>
</author>
<author><name sortKey="Garbin, Cezar Augusto" sort="Garbin, Cezar Augusto" uniqKey="Garbin C" first="Cezar Augusto" last="Garbin">Cezar Augusto Garbin</name>
</author>
<author><name sortKey="Schuh, Cristian" sort="Schuh, Cristian" uniqKey="Schuh C" first="Cristian" last="Schuh">Cristian Schuh</name>
</author>
<author><name sortKey="Boscato, Noeli" sort="Boscato, Noeli" uniqKey="Boscato N" first="Noeli" last="Boscato">Noeli Boscato</name>
</author>
</analytic>
<series><title level="j">General dentistry</title>
<idno type="ISSN">0363-6771</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Dental Abutments</term>
<term>Dental Implantation, Endosseous (instrumentation)</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>Dental Prosthesis, Implant-Supported (instrumentation)</term>
<term>Denture Retention</term>
<term>Denture, Complete, Lower</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Male</term>
<term>Mandible</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Dental Implantation, Endosseous</term>
<term>Dental Prosthesis, Implant-Supported</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Dental Abutments</term>
<term>Dental Prosthesis Design</term>
<term>Denture Retention</term>
<term>Denture, Complete, Lower</term>
<term>Denture, Overlay</term>
<term>Humans</term>
<term>Male</term>
<term>Mandible</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">An implant-retained overdenture is less expensive than a fixed implant-retained prosthesis; however, using ball attachments on abutments that are nonparallel and/or outside the path of insertion may result in loss of retention. As described in this case report, alignment devices can be used as a mandibular overdenture retainer to diminish the lack of parallelism between two implants. The treatment plan involved the use of an alignment device on each implant to ensure correct alignment among ball attachments and its retentive component. These devices can be used to fabricate overdentures retained by implants that are misaligned by as much as 14 degrees.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">20591765</PMID>
<DateCompleted><Year>2010</Year>
<Month>11</Month>
<Day>12</Day>
</DateCompleted>
<DateRevised><Year>2010</Year>
<Month>07</Month>
<Day>01</Day>
</DateRevised>
<Article PubModel="Print"><Journal><ISSN IssnType="Print">0363-6771</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>58</Volume>
<Issue>4</Issue>
<PubDate><MedlineDate>2010 Jul-Aug</MedlineDate>
</PubDate>
</JournalIssue>
<Title>General dentistry</Title>
<ISOAbbreviation>Gen Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Correction of nonparallel implants for an implant-retained overdenture.</ArticleTitle>
<Pagination><MedlinePgn>e168-71</MedlinePgn>
</Pagination>
<Abstract><AbstractText>An implant-retained overdenture is less expensive than a fixed implant-retained prosthesis; however, using ball attachments on abutments that are nonparallel and/or outside the path of insertion may result in loss of retention. As described in this case report, alignment devices can be used as a mandibular overdenture retainer to diminish the lack of parallelism between two implants. The treatment plan involved the use of an alignment device on each implant to ensure correct alignment among ball attachments and its retentive component. These devices can be used to fabricate overdentures retained by implants that are misaligned by as much as 14 degrees.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Nunes</LastName>
<ForeName>Daniel Becker</ForeName>
<Initials>DB</Initials>
<AffiliationInfo><Affiliation>Department of Prosthodontics, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>da Silva</LastName>
<ForeName>Paulo</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y"><LastName>Pereira-Cenci</LastName>
<ForeName>Tatiana</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y"><LastName>Garbin</LastName>
<ForeName>Cezar Augusto</ForeName>
<Initials>CA</Initials>
</Author>
<Author ValidYN="Y"><LastName>Schuh</LastName>
<ForeName>Cristian</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y"><LastName>Boscato</LastName>
<ForeName>Noeli</ForeName>
<Initials>N</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Gen Dent</MedlineTA>
<NlmUniqueID>7610466</NlmUniqueID>
<ISSNLinking>0363-6771</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="N">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017267" MajorTopicYN="Y">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="N">Dental Prosthesis, Implant-Supported</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003826" MajorTopicYN="Y">Denture, Complete, Lower</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="Y">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D016896" MajorTopicYN="N">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2010</Year>
<Month>7</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2010</Year>
<Month>7</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2010</Year>
<Month>11</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">20591765</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001891 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001891 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:20591765 |texte= Correction of nonparallel implants for an implant-retained overdenture. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:20591765" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |