The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.
Identifieur interne : 001140 ( PubMed/Corpus ); précédent : 001139; suivant : 001141The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.
Auteurs : Carlo Ercoli ; Alessandro Geminiani ; Changyong Feng ; Heeje LeeSource :
- Clinical implant dentistry and related research [ 1708-8208 ] ; 2012.
English descriptors
- KwdEn :
- Acrylic Resins (chemistry), Aged, Computer-Aided Design, Dental Alloys (chemistry), Dental Casting Investment (chemistry), Dental Implant-Abutment Design, Dental Implants, Dental Impression Materials (chemistry), Dental Impression Technique (instrumentation), Dental Marginal Adaptation, Dental Materials (chemistry), Dental Prosthesis, Implant-Supported, Denture Design (instrumentation), Denture, Complete, Elastomers (chemistry), Humans, Jaw, Edentulous (rehabilitation), Middle Aged, Polyvinyls (chemistry), Retrospective Studies, Siloxanes (chemistry), Titanium (chemistry).
- MESH :
- chemical , chemistry : Acrylic Resins, Dental Alloys, Dental Casting Investment, Dental Impression Materials, Dental Materials, Elastomers, Polyvinyls, Siloxanes, Titanium.
- instrumentation : Dental Impression Technique, Denture Design.
- rehabilitation : Jaw, Edentulous.
- Aged, Computer-Aided Design, Dental Implant-Abutment Design, Dental Implants, Dental Marginal Adaptation, Dental Prosthesis, Implant-Supported, Denture, Complete, Humans, Middle Aged, Retrospective Studies.
Abstract
The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig.
DOI: 10.1111/j.1708-8208.2011.00425.x
PubMed: 22176765
Links to Exploration step
pubmed:22176765Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.</title>
<author><name sortKey="Ercoli, Carlo" sort="Ercoli, Carlo" uniqKey="Ercoli C" first="Carlo" last="Ercoli">Carlo Ercoli</name>
<affiliation><nlm:affiliation>Division of Prosthodontics, Eastman Institute for Oral Health, School of Medicine and Dentistry, University of Rochester, Rochester, NY 14620, USA. carlo_ercoli@urmc.rochester.edu</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Geminiani, Alessandro" sort="Geminiani, Alessandro" uniqKey="Geminiani A" first="Alessandro" last="Geminiani">Alessandro Geminiani</name>
</author>
<author><name sortKey="Feng, Changyong" sort="Feng, Changyong" uniqKey="Feng C" first="Changyong" last="Feng">Changyong Feng</name>
</author>
<author><name sortKey="Lee, Heeje" sort="Lee, Heeje" uniqKey="Lee H" first="Heeje" last="Lee">Heeje Lee</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:22176765</idno>
<idno type="pmid">22176765</idno>
<idno type="doi">10.1111/j.1708-8208.2011.00425.x</idno>
<idno type="wicri:Area/PubMed/Corpus">001140</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001140</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.</title>
<author><name sortKey="Ercoli, Carlo" sort="Ercoli, Carlo" uniqKey="Ercoli C" first="Carlo" last="Ercoli">Carlo Ercoli</name>
<affiliation><nlm:affiliation>Division of Prosthodontics, Eastman Institute for Oral Health, School of Medicine and Dentistry, University of Rochester, Rochester, NY 14620, USA. carlo_ercoli@urmc.rochester.edu</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Geminiani, Alessandro" sort="Geminiani, Alessandro" uniqKey="Geminiani A" first="Alessandro" last="Geminiani">Alessandro Geminiani</name>
</author>
<author><name sortKey="Feng, Changyong" sort="Feng, Changyong" uniqKey="Feng C" first="Changyong" last="Feng">Changyong Feng</name>
</author>
<author><name sortKey="Lee, Heeje" sort="Lee, Heeje" uniqKey="Lee H" first="Heeje" last="Lee">Heeje Lee</name>
</author>
</analytic>
<series><title level="j">Clinical implant dentistry and related research</title>
<idno type="eISSN">1708-8208</idno>
<imprint><date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins (chemistry)</term>
<term>Aged</term>
<term>Computer-Aided Design</term>
<term>Dental Alloys (chemistry)</term>
<term>Dental Casting Investment (chemistry)</term>
<term>Dental Implant-Abutment Design</term>
<term>Dental Implants</term>
<term>Dental Impression Materials (chemistry)</term>
<term>Dental Impression Technique (instrumentation)</term>
<term>Dental Marginal Adaptation</term>
<term>Dental Materials (chemistry)</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture Design (instrumentation)</term>
<term>Denture, Complete</term>
<term>Elastomers (chemistry)</term>
<term>Humans</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Middle Aged</term>
<term>Polyvinyls (chemistry)</term>
<term>Retrospective Studies</term>
<term>Siloxanes (chemistry)</term>
<term>Titanium (chemistry)</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en"><term>Acrylic Resins</term>
<term>Dental Alloys</term>
<term>Dental Casting Investment</term>
<term>Dental Impression Materials</term>
<term>Dental Materials</term>
<term>Elastomers</term>
<term>Polyvinyls</term>
<term>Siloxanes</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Dental Impression Technique</term>
<term>Denture Design</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Computer-Aided Design</term>
<term>Dental Implant-Abutment Design</term>
<term>Dental Implants</term>
<term>Dental Marginal Adaptation</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Complete</term>
<term>Humans</term>
<term>Middle Aged</term>
<term>Retrospective Studies</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">22176765</PMID>
<DateCompleted><Year>2012</Year>
<Month>10</Month>
<Day>24</Day>
</DateCompleted>
<DateRevised><Year>2014</Year>
<Month>07</Month>
<Day>31</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1708-8208</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>14 Suppl 1</Volume>
<PubDate><Year>2012</Year>
<Month>May</Month>
</PubDate>
</JournalIssue>
<Title>Clinical implant dentistry and related research</Title>
<ISOAbbreviation>Clin Implant Dent Relat Res</ISOAbbreviation>
</Journal>
<ArticleTitle>The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.</ArticleTitle>
<Pagination><MedlinePgn>e188-95</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/j.1708-8208.2011.00425.x</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture.</AbstractText>
<CopyrightInformation>© 2011 Wiley Periodicals, Inc.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Ercoli</LastName>
<ForeName>Carlo</ForeName>
<Initials>C</Initials>
<AffiliationInfo><Affiliation>Division of Prosthodontics, Eastman Institute for Oral Health, School of Medicine and Dentistry, University of Rochester, Rochester, NY 14620, USA. carlo_ercoli@urmc.rochester.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Geminiani</LastName>
<ForeName>Alessandro</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y"><LastName>Feng</LastName>
<ForeName>Changyong</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y"><LastName>Lee</LastName>
<ForeName>Heeje</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2011</Year>
<Month>12</Month>
<Day>16</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Clin Implant Dent Relat Res</MedlineTA>
<NlmUniqueID>100888977</NlmUniqueID>
<ISSNLinking>1523-0899</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003722">Dental Alloys</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003734">Dental Casting Investment</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003760">Dental Impression Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003764">Dental Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D020724">Elastomers</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C495447">Permadyne</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011145">Polyvinyls</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D012833">Siloxanes</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C034183">vinyl polysiloxane</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>12743-70-3</RegistryNumber>
<NameOfSubstance UI="C031462">titanium alloy (TiAl6V4)</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003722" MajorTopicYN="N">Dental Alloys</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003734" MajorTopicYN="N">Dental Casting Investment</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D059605" MajorTopicYN="N">Dental Implant-Abutment Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003760" MajorTopicYN="N">Dental Impression Materials</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003761" MajorTopicYN="N">Dental Impression Technique</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D018772" MajorTopicYN="Y">Dental Marginal Adaptation</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003764" MajorTopicYN="N">Dental Materials</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003824" MajorTopicYN="Y">Denture, Complete</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D020724" MajorTopicYN="N">Elastomers</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011145" MajorTopicYN="N">Polyvinyls</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012189" MajorTopicYN="N">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012833" MajorTopicYN="N">Siloxanes</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2011</Year>
<Month>12</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2011</Year>
<Month>12</Month>
<Day>20</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2012</Year>
<Month>10</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">22176765</ArticleId>
<ArticleId IdType="doi">10.1111/j.1708-8208.2011.00425.x</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001140 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001140 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:22176765 |texte= The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:22176765" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |