Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.

Identifieur interne : 001060 ( PubMed/Corpus ); précédent : 001059; suivant : 001061

Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.

Auteurs : Jan D'Haese ; Tommie Van De Velde ; Ai Komiyama ; Margaretha Hultin ; Hugo De Bruyn

Source :

RBID : pubmed:20491822

English descriptors

Abstract

In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting.

DOI: 10.1111/j.1708-8208.2010.00275.x
PubMed: 20491822

Links to Exploration step

pubmed:20491822

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.</title>
<author>
<name sortKey="D Haese, Jan" sort="D Haese, Jan" uniqKey="D Haese J" first="Jan" last="D'Haese">Jan D'Haese</name>
<affiliation>
<nlm:affiliation>Tandkliniek Sint-Lievens-Houtem, Sint-Lievens-Houtem, Belgium. jdhaese@base.be</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Van De Velde, Tommie" sort="Van De Velde, Tommie" uniqKey="Van De Velde T" first="Tommie" last="Van De Velde">Tommie Van De Velde</name>
</author>
<author>
<name sortKey="Komiyama, Ai" sort="Komiyama, Ai" uniqKey="Komiyama A" first="Ai" last="Komiyama">Ai Komiyama</name>
</author>
<author>
<name sortKey="Hultin, Margaretha" sort="Hultin, Margaretha" uniqKey="Hultin M" first="Margaretha" last="Hultin">Margaretha Hultin</name>
</author>
<author>
<name sortKey="De Bruyn, Hugo" sort="De Bruyn, Hugo" uniqKey="De Bruyn H" first="Hugo" last="De Bruyn">Hugo De Bruyn</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:20491822</idno>
<idno type="pmid">20491822</idno>
<idno type="doi">10.1111/j.1708-8208.2010.00275.x</idno>
<idno type="wicri:Area/PubMed/Corpus">001060</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001060</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.</title>
<author>
<name sortKey="D Haese, Jan" sort="D Haese, Jan" uniqKey="D Haese J" first="Jan" last="D'Haese">Jan D'Haese</name>
<affiliation>
<nlm:affiliation>Tandkliniek Sint-Lievens-Houtem, Sint-Lievens-Houtem, Belgium. jdhaese@base.be</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Van De Velde, Tommie" sort="Van De Velde, Tommie" uniqKey="Van De Velde T" first="Tommie" last="Van De Velde">Tommie Van De Velde</name>
</author>
<author>
<name sortKey="Komiyama, Ai" sort="Komiyama, Ai" uniqKey="Komiyama A" first="Ai" last="Komiyama">Ai Komiyama</name>
</author>
<author>
<name sortKey="Hultin, Margaretha" sort="Hultin, Margaretha" uniqKey="Hultin M" first="Margaretha" last="Hultin">Margaretha Hultin</name>
</author>
<author>
<name sortKey="De Bruyn, Hugo" sort="De Bruyn, Hugo" uniqKey="De Bruyn H" first="Hugo" last="De Bruyn">Hugo De Bruyn</name>
</author>
</analytic>
<series>
<title level="j">Clinical implant dentistry and related research</title>
<idno type="eISSN">1708-8208</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Restoration Failure</term>
<term>Dimensional Measurement Accuracy</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Models, Anatomic</term>
<term>Patient Care Planning</term>
<term>Photography, Dental</term>
<term>Postoperative Complications</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted (instrumentation)</term>
<term>Zygoma (surgery)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Zygoma</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Restoration Failure</term>
<term>Dimensional Measurement Accuracy</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Models, Anatomic</term>
<term>Patient Care Planning</term>
<term>Photography, Dental</term>
<term>Postoperative Complications</term>
<term>Radiography</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">20491822</PMID>
<DateCompleted>
<Year>2012</Year>
<Month>12</Month>
<Day>03</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print-Electronic">
<Journal>
<ISSN IssnType="Electronic">1708-8208</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>14</Volume>
<Issue>3</Issue>
<PubDate>
<Year>2012</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Clinical implant dentistry and related research</Title>
<ISOAbbreviation>Clin Implant Dent Relat Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.</ArticleTitle>
<Pagination>
<MedlinePgn>321-35</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/j.1708-8208.2010.00275.x</ELocationID>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting.</AbstractText>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To review data on accuracy and surgical and prosthodontical complications using stereolithographical surgical guides for implant rehabilitation.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">PubMed database was searched using the following keywords: "three dimensional imaging,"image based surgery,"flapless guided surgery,"customized drill guides,"computer assisted surgery,"surgical template," and "stereolithography." Only papers in English were selected. Additional references found through reading of selected papers completed the list.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">In total 31 papers were selected. Ten reported deviations between the preoperative implant planning and the postoperative implant locations. One in vitro study reported a mean apical deviation of 1.0 mm, three ex vivo studies a mean apical deviation ranging between 0.6 and 1.2 mm. In six in vivo studies an apical deviation between 0.95 and 4.5 mm was found. Six papers reported on complications mounting to 42% of the cases when stereolithographic guided surgery was combined with immediate loading.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Substantial deviations in three-dimensional directions are found between virtual planning and actually obtained implant position. This finding and additionally reported postsurgical complications leads to the conclusion that care should be taken whenever applying this technique on a routine basis.</AbstractText>
<CopyrightInformation>© 2010 Wiley Periodicals, Inc.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>D'haese</LastName>
<ForeName>Jan</ForeName>
<Initials>J</Initials>
<AffiliationInfo>
<Affiliation>Tandkliniek Sint-Lievens-Houtem, Sint-Lievens-Houtem, Belgium. jdhaese@base.be</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Van De Velde</LastName>
<ForeName>Tommie</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Komiyama</LastName>
<ForeName>Ai</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hultin</LastName>
<ForeName>Margaretha</ForeName>
<Initials>M</Initials>
</Author>
<Author ValidYN="Y">
<LastName>De Bruyn</LastName>
<ForeName>Hugo</ForeName>
<Initials>H</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016454">Review</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic">
<Year>2010</Year>
<Month>05</Month>
<Day>11</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Clin Implant Dent Relat Res</MedlineTA>
<NlmUniqueID>100888977</NlmUniqueID>
<ISSNLinking>1523-0899</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019232" MajorTopicYN="N">Dental Restoration Failure</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D061827" MajorTopicYN="N">Dimensional Measurement Accuracy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007091" MajorTopicYN="Y">Image Processing, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008953" MajorTopicYN="Y">Models, Anatomic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D023861" MajorTopicYN="N">Photography, Dental</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011183" MajorTopicYN="N">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015050" MajorTopicYN="N">Zygoma</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="N">surgery</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2010</Year>
<Month>5</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2010</Year>
<Month>5</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2012</Year>
<Month>12</Month>
<Day>10</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">20491822</ArticleId>
<ArticleId IdType="pii">CID275</ArticleId>
<ArticleId IdType="doi">10.1111/j.1708-8208.2010.00275.x</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001060 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 001060 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:20491822
   |texte=   Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:20491822" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022