How some ridge shapes affect the fit of denture bases.

Identifieur interne : 000E42 ( PubMed/Corpus ); précédent : 000E41; suivant : 000E43

How some ridge shapes affect the fit of denture bases.

Auteurs : Y. Altarakemah ; K J Soderholm

Source :

RBID : pubmed:23495561

English descriptors

Abstract

Polymerization shrinkage can result in poor denture fit. The aim of this study was to determine the accuracy of heat-polymerized acrylic bases on simulated edentulous metal ridges having simplified and standardized geometric configurations. Analysis of variance was used to explore the relationship between fit and ridge-slope/ridge-convergences. The outcome of that analysis revealed that the discrepancies between the base plates decreased significantly (p < 0.05) as both the ridge slope decreased and the anterior-sagital convergence increased. These geometric correlations can help clinicians to anticipate potential areas of sore spots on residual ridges when delivering complete dentures.

PubMed: 23495561

Links to Exploration step

pubmed:23495561

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">How some ridge shapes affect the fit of denture bases.</title>
<author>
<name sortKey="Altarakemah, Y" sort="Altarakemah, Y" uniqKey="Altarakemah Y" first="Y" last="Altarakemah">Y. Altarakemah</name>
<affiliation>
<nlm:affiliation>Department of Restorative Sciences, College of Dentistry-Kuwait University, Kuwait City, Kuwait. Yacoub@hsc.edu.kw</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Soderholm, K J" sort="Soderholm, K J" uniqKey="Soderholm K" first="K J" last="Soderholm">K J Soderholm</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="RBID">pubmed:23495561</idno>
<idno type="pmid">23495561</idno>
<idno type="wicri:Area/PubMed/Corpus">000E42</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000E42</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">How some ridge shapes affect the fit of denture bases.</title>
<author>
<name sortKey="Altarakemah, Y" sort="Altarakemah, Y" uniqKey="Altarakemah Y" first="Y" last="Altarakemah">Y. Altarakemah</name>
<affiliation>
<nlm:affiliation>Department of Restorative Sciences, College of Dentistry-Kuwait University, Kuwait City, Kuwait. Yacoub@hsc.edu.kw</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Soderholm, K J" sort="Soderholm, K J" uniqKey="Soderholm K" first="K J" last="Soderholm">K J Soderholm</name>
</author>
</analytic>
<series>
<title level="j">The European journal of prosthodontics and restorative dentistry</title>
<idno type="ISSN">0965-7452</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic Resins (chemistry)</term>
<term>Aluminum (chemistry)</term>
<term>Alveolar Process (pathology)</term>
<term>Cephalometry</term>
<term>Dental Arch (pathology)</term>
<term>Dental Materials (chemistry)</term>
<term>Denture Bases</term>
<term>Denture Design</term>
<term>Denture Retention</term>
<term>Humans</term>
<term>Jaw, Edentulous (pathology)</term>
<term>Maxilla (pathology)</term>
<term>Models, Anatomic</term>
<term>Polymerization</term>
<term>Prosthesis Fitting</term>
<term>Surface Properties</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Acrylic Resins</term>
<term>Aluminum</term>
<term>Dental Materials</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Alveolar Process</term>
<term>Dental Arch</term>
<term>Jaw, Edentulous</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Cephalometry</term>
<term>Denture Bases</term>
<term>Denture Design</term>
<term>Denture Retention</term>
<term>Humans</term>
<term>Models, Anatomic</term>
<term>Polymerization</term>
<term>Prosthesis Fitting</term>
<term>Surface Properties</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Polymerization shrinkage can result in poor denture fit. The aim of this study was to determine the accuracy of heat-polymerized acrylic bases on simulated edentulous metal ridges having simplified and standardized geometric configurations. Analysis of variance was used to explore the relationship between fit and ridge-slope/ridge-convergences. The outcome of that analysis revealed that the discrepancies between the base plates decreased significantly (p < 0.05) as both the ridge slope decreased and the anterior-sagital convergence increased. These geometric correlations can help clinicians to anticipate potential areas of sore spots on residual ridges when delivering complete dentures.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23495561</PMID>
<DateCompleted>
<Year>2013</Year>
<Month>04</Month>
<Day>09</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0965-7452</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>20</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2012</Year>
<Month>Dec</Month>
</PubDate>
</JournalIssue>
<Title>The European journal of prosthodontics and restorative dentistry</Title>
<ISOAbbreviation>Eur J Prosthodont Restor Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>How some ridge shapes affect the fit of denture bases.</ArticleTitle>
<Pagination>
<MedlinePgn>184-90</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Polymerization shrinkage can result in poor denture fit. The aim of this study was to determine the accuracy of heat-polymerized acrylic bases on simulated edentulous metal ridges having simplified and standardized geometric configurations. Analysis of variance was used to explore the relationship between fit and ridge-slope/ridge-convergences. The outcome of that analysis revealed that the discrepancies between the base plates decreased significantly (p < 0.05) as both the ridge slope decreased and the anterior-sagital convergence increased. These geometric correlations can help clinicians to anticipate potential areas of sore spots on residual ridges when delivering complete dentures.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>AlTarakemah</LastName>
<ForeName>Y</ForeName>
<Initials>Y</Initials>
<AffiliationInfo>
<Affiliation>Department of Restorative Sciences, College of Dentistry-Kuwait University, Kuwait City, Kuwait. Yacoub@hsc.edu.kw</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Soderholm</LastName>
<ForeName>K J</ForeName>
<Initials>KJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Eur J Prosthodont Restor Dent</MedlineTA>
<NlmUniqueID>9314899</NlmUniqueID>
<ISSNLinking>0965-7452</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003764">Dental Materials</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>CPD4NFA903</RegistryNumber>
<NameOfSubstance UI="D000535">Aluminum</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000535" MajorTopicYN="N">Aluminum</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000539" MajorTopicYN="N">Alveolar Process</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D002508" MajorTopicYN="N">Cephalometry</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003724" MajorTopicYN="N">Dental Arch</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003764" MajorTopicYN="N">Dental Materials</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003819" MajorTopicYN="Y">Denture Bases</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008953" MajorTopicYN="N">Models, Anatomic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D058105" MajorTopicYN="N">Polymerization</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017755" MajorTopicYN="Y">Prosthesis Fitting</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013499" MajorTopicYN="N">Surface Properties</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>3</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>3</Month>
<Day>19</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2013</Year>
<Month>4</Month>
<Day>10</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23495561</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E42 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000E42 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:23495561
   |texte=   How some ridge shapes affect the fit of denture bases.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:23495561" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022