Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Assessing the feasibility and accuracy of digitizing edentulous jaws.

Identifieur interne : 000B99 ( PubMed/Corpus ); précédent : 000B98; suivant : 000C00

Assessing the feasibility and accuracy of digitizing edentulous jaws.

Auteurs : Sebastian B M. Patzelt ; Sebastian Vonau ; Susanne Stampf ; Wael Att

Source :

RBID : pubmed:23904578

English descriptors

Abstract

Despite the accuracy of intraoral scanners (IOSs) in producing single-unit scans and the possibility of generating complete dentures digitally, little is known about their feasibility and accuracy in digitizing edentulous jaws. The purpose of this in vitro investigation was to evaluate the feasibility and accuracy of digitizing edentulous jaw models with IOSs.

PubMed: 23904578

Links to Exploration step

pubmed:23904578

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Assessing the feasibility and accuracy of digitizing edentulous jaws.</title>
<author>
<name sortKey="Patzelt, Sebastian B M" sort="Patzelt, Sebastian B M" uniqKey="Patzelt S" first="Sebastian B M" last="Patzelt">Sebastian B M. Patzelt</name>
<affiliation>
<nlm:affiliation>Department of Periodontics, School of Dentistry, University of Maryland, Baltimore, MD 21201, USA. spatzelt@umaryland.edu</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vonau, Sebastian" sort="Vonau, Sebastian" uniqKey="Vonau S" first="Sebastian" last="Vonau">Sebastian Vonau</name>
</author>
<author>
<name sortKey="Stampf, Susanne" sort="Stampf, Susanne" uniqKey="Stampf S" first="Susanne" last="Stampf">Susanne Stampf</name>
</author>
<author>
<name sortKey="Att, Wael" sort="Att, Wael" uniqKey="Att W" first="Wael" last="Att">Wael Att</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:23904578</idno>
<idno type="pmid">23904578</idno>
<idno type="wicri:Area/PubMed/Corpus">000B99</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000B99</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Assessing the feasibility and accuracy of digitizing edentulous jaws.</title>
<author>
<name sortKey="Patzelt, Sebastian B M" sort="Patzelt, Sebastian B M" uniqKey="Patzelt S" first="Sebastian B M" last="Patzelt">Sebastian B M. Patzelt</name>
<affiliation>
<nlm:affiliation>Department of Periodontics, School of Dentistry, University of Maryland, Baltimore, MD 21201, USA. spatzelt@umaryland.edu</nlm:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Vonau, Sebastian" sort="Vonau, Sebastian" uniqKey="Vonau S" first="Sebastian" last="Vonau">Sebastian Vonau</name>
</author>
<author>
<name sortKey="Stampf, Susanne" sort="Stampf, Susanne" uniqKey="Stampf S" first="Susanne" last="Stampf">Susanne Stampf</name>
</author>
<author>
<name sortKey="Att, Wael" sort="Att, Wael" uniqKey="Att W" first="Wael" last="Att">Wael Att</name>
</author>
</analytic>
<series>
<title level="j">Journal of the American Dental Association (1939)</title>
<idno type="eISSN">1943-4723</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer-Aided Design (instrumentation)</term>
<term>Computer-Aided Design (statistics & numerical data)</term>
<term>Dental Impression Technique (instrumentation)</term>
<term>Dental Impression Technique (statistics & numerical data)</term>
<term>Dental Models</term>
<term>Feasibility Studies</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted (statistics & numerical data)</term>
<term>Imaging, Three-Dimensional (statistics & numerical data)</term>
<term>Jaw, Edentulous (pathology)</term>
<term>Lasers</term>
<term>Mandible (pathology)</term>
<term>Maxilla (pathology)</term>
<term>Software (statistics & numerical data)</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Impression Technique</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
<term>Maxilla</term>
</keywords>
<keywords scheme="MESH" qualifier="statistics & numerical data" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Impression Technique</term>
<term>Image Processing, Computer-Assisted</term>
<term>Imaging, Three-Dimensional</term>
<term>Software</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Dental Models</term>
<term>Feasibility Studies</term>
<term>Humans</term>
<term>Lasers</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Despite the accuracy of intraoral scanners (IOSs) in producing single-unit scans and the possibility of generating complete dentures digitally, little is known about their feasibility and accuracy in digitizing edentulous jaws. The purpose of this in vitro investigation was to evaluate the feasibility and accuracy of digitizing edentulous jaw models with IOSs.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23904578</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>04</Month>
<Day>08</Day>
</DateCompleted>
<DateRevised>
<Year>2013</Year>
<Month>08</Month>
<Day>01</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1943-4723</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>144</Volume>
<Issue>8</Issue>
<PubDate>
<Year>2013</Year>
<Month>Aug</Month>
</PubDate>
</JournalIssue>
<Title>Journal of the American Dental Association (1939)</Title>
<ISOAbbreviation>J Am Dent Assoc</ISOAbbreviation>
</Journal>
<ArticleTitle>Assessing the feasibility and accuracy of digitizing edentulous jaws.</ArticleTitle>
<Pagination>
<MedlinePgn>914-20</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">Despite the accuracy of intraoral scanners (IOSs) in producing single-unit scans and the possibility of generating complete dentures digitally, little is known about their feasibility and accuracy in digitizing edentulous jaws. The purpose of this in vitro investigation was to evaluate the feasibility and accuracy of digitizing edentulous jaw models with IOSs.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">The authors used an industrial laser scanner (reference scanner) and four IOSs to digitize two representative edentulous jaw models. They loaded the data sets obtained into three-dimensional evaluation software, superimposed the data sets and compared them for accuracy. The authors used a one-way analysis of variance to compute differences within groups (precision), as well as to compare values with those of the reference scanner (trueness) (statistical significance, P < .05).</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Mean trueness values ranged from 44.1 to 591.8 micrometers. Data analysis yielded statistically significant differences in trueness between all scanners (P < .05). Mean precision values ranged from 21.6 to 698.0 μm. The study results showed statistically significant differences in precision between all scanners (P < .05), except for the CEREC AC Bluecam (Sirona, Bensheim, Germany) and the Zfx IntraScan (manufactured by MHT Italy, Negrar, Italy/ MHT Optic Research, Niederhasli, Switzerland; distributed by Zfx, Dachau, Germany) (P > .05).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Digitizing edentulous jaw models with the use of IOSs appears to be feasible, although the accuracy of the scanners differs significantly. The results of this study showed that only one scanner was sufficiently accurate to warrant further intraoral investigations. Further enhancements are necessary to recommend these IOSs for this particular indication. Practical Implications. On the basis of the results of this study, the authors cannot recommend these four IOSs for digitization of edentulous jaws in vivo.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Patzelt</LastName>
<ForeName>Sebastian B M</ForeName>
<Initials>SB</Initials>
<AffiliationInfo>
<Affiliation>Department of Periodontics, School of Dentistry, University of Maryland, Baltimore, MD 21201, USA. spatzelt@umaryland.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Vonau</LastName>
<ForeName>Sebastian</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Stampf</LastName>
<ForeName>Susanne</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Att</LastName>
<ForeName>Wael</ForeName>
<Initials>W</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>J Am Dent Assoc</MedlineTA>
<NlmUniqueID>7503060</NlmUniqueID>
<ISSNLinking>0002-8177</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003761" MajorTopicYN="N">Dental Impression Technique</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005240" MajorTopicYN="N">Feasibility Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007091" MajorTopicYN="N">Image Processing, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="Y">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D021621" MajorTopicYN="N">Imaging, Three-Dimensional</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007834" MajorTopicYN="N">Lasers</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="N">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012984" MajorTopicYN="N">Software</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM">
<Keyword MajorTopicYN="N">Intraoral scanner</Keyword>
<Keyword MajorTopicYN="N">accuracy</Keyword>
<Keyword MajorTopicYN="N">digital impression</Keyword>
<Keyword MajorTopicYN="N">edentulous jaws</Keyword>
<Keyword MajorTopicYN="N">precision</Keyword>
<Keyword MajorTopicYN="N">trueness</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>8</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>8</Month>
<Day>2</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>4</Month>
<Day>9</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23904578</ArticleId>
<ArticleId IdType="pii">S0002-8177(14)60511-0</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B99 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000B99 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:23904578
   |texte=   Assessing the feasibility and accuracy of digitizing edentulous jaws.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:23904578" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022