Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.
Identifieur interne : 000523 ( PubMed/Corpus ); précédent : 000522; suivant : 000524Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.
Auteurs : Christoph Vasak ; Georg D. Strbac ; Christian D. Huber ; Stefan Lettner ; André Gahleitner ; Werner ZechnerSource :
- Clinical implant dentistry and related research [ 1708-8208 ] ; 2015.
English descriptors
- KwdEn :
- MESH :
- chemical : Dental Implants, Polyurethanes.
- methods : Dental Implantation, Endosseous.
- rehabilitation : Jaw, Edentulous.
- Computer-Aided Design, Dental Prosthesis Design, In Vitro Techniques, Mandible, Software, Surgery, Computer-Assisted, Treatment Outcome.
Abstract
The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method.
DOI: 10.1111/cid.12085
PubMed: 23679124
Links to Exploration step
pubmed:23679124Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.</title>
<author><name sortKey="Vasak, Christoph" sort="Vasak, Christoph" uniqKey="Vasak C" first="Christoph" last="Vasak">Christoph Vasak</name>
<affiliation><nlm:affiliation>Department of Oral Surgery, Bernhard Gottlieb University School of Dentistry, Medical University of Vienna, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Strbac, Georg D" sort="Strbac, Georg D" uniqKey="Strbac G" first="Georg D" last="Strbac">Georg D. Strbac</name>
</author>
<author><name sortKey="Huber, Christian D" sort="Huber, Christian D" uniqKey="Huber C" first="Christian D" last="Huber">Christian D. Huber</name>
</author>
<author><name sortKey="Lettner, Stefan" sort="Lettner, Stefan" uniqKey="Lettner S" first="Stefan" last="Lettner">Stefan Lettner</name>
</author>
<author><name sortKey="Gahleitner, Andre" sort="Gahleitner, Andre" uniqKey="Gahleitner A" first="André" last="Gahleitner">André Gahleitner</name>
</author>
<author><name sortKey="Zechner, Werner" sort="Zechner, Werner" uniqKey="Zechner W" first="Werner" last="Zechner">Werner Zechner</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="RBID">pubmed:23679124</idno>
<idno type="pmid">23679124</idno>
<idno type="doi">10.1111/cid.12085</idno>
<idno type="wicri:Area/PubMed/Corpus">000523</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000523</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.</title>
<author><name sortKey="Vasak, Christoph" sort="Vasak, Christoph" uniqKey="Vasak C" first="Christoph" last="Vasak">Christoph Vasak</name>
<affiliation><nlm:affiliation>Department of Oral Surgery, Bernhard Gottlieb University School of Dentistry, Medical University of Vienna, Vienna, Austria.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Strbac, Georg D" sort="Strbac, Georg D" uniqKey="Strbac G" first="Georg D" last="Strbac">Georg D. Strbac</name>
</author>
<author><name sortKey="Huber, Christian D" sort="Huber, Christian D" uniqKey="Huber C" first="Christian D" last="Huber">Christian D. Huber</name>
</author>
<author><name sortKey="Lettner, Stefan" sort="Lettner, Stefan" uniqKey="Lettner S" first="Stefan" last="Lettner">Stefan Lettner</name>
</author>
<author><name sortKey="Gahleitner, Andre" sort="Gahleitner, Andre" uniqKey="Gahleitner A" first="André" last="Gahleitner">André Gahleitner</name>
</author>
<author><name sortKey="Zechner, Werner" sort="Zechner, Werner" uniqKey="Zechner W" first="Werner" last="Zechner">Werner Zechner</name>
</author>
</analytic>
<series><title level="j">Clinical implant dentistry and related research</title>
<idno type="eISSN">1708-8208</idno>
<imprint><date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Implants</term>
<term>Dental Prosthesis Design</term>
<term>In Vitro Techniques</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Mandible</term>
<term>Polyurethanes</term>
<term>Software</term>
<term>Surgery, Computer-Assisted</term>
<term>Treatment Outcome</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Dental Implants</term>
<term>Polyurethanes</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Computer-Aided Design</term>
<term>Dental Prosthesis Design</term>
<term>In Vitro Techniques</term>
<term>Mandible</term>
<term>Software</term>
<term>Surgery, Computer-Assisted</term>
<term>Treatment Outcome</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">23679124</PMID>
<DateCompleted><Year>2016</Year>
<Month>12</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised><Year>2016</Year>
<Month>12</Month>
<Day>30</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">1708-8208</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>17</Volume>
<Issue>1</Issue>
<PubDate><Year>2015</Year>
<Month>Feb</Month>
</PubDate>
</JournalIssue>
<Title>Clinical implant dentistry and related research</Title>
<ISOAbbreviation>Clin Implant Dent Relat Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study.</ArticleTitle>
<Pagination><MedlinePgn>142-9</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1111/cid.12085</ELocationID>
<Abstract><AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">Overall, 60 implants were placed in 10 artificial edentulous mandibles according to the NobelGuide™ protocol. For merging the pre- and postoperative DICOM data sets, three different fusion methods (Triple Scan Technique, NobelGuide™ Validation software, and AMIRA® software [VSG - Visualization Sciences Group, Burlington, MA, USA] as reference) were applied. Discrepancies between the virtual and the actual implant positions were measured.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The mean deviations measured with AMIRA® were 0.49 mm (implant shoulder), 0.69 mm (implant apex), and 1.98°mm (implant axis). The Triple Scan Technique as well as the NobelGuide™ Validation software revealed similar deviations compared with the reference method. A significant correlation between angular and apical deviations was seen (r = 0.53; p < .001). A greater implant diameter was associated with greater deviations (p = .03).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">The Triple Scan Technique as a system-independent validation procedure as well as the NobelGuide™ Validation software are in accordance with the AMIRA® software. The NobelGuide™ system showed similar or less spatial and angular deviations compared with others.</AbstractText>
<CopyrightInformation>© 2013 Wiley Periodicals, Inc.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Vasak</LastName>
<ForeName>Christoph</ForeName>
<Initials>C</Initials>
<AffiliationInfo><Affiliation>Department of Oral Surgery, Bernhard Gottlieb University School of Dentistry, Medical University of Vienna, Vienna, Austria.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Strbac</LastName>
<ForeName>Georg D</ForeName>
<Initials>GD</Initials>
</Author>
<Author ValidYN="Y"><LastName>Huber</LastName>
<ForeName>Christian D</ForeName>
<Initials>CD</Initials>
</Author>
<Author ValidYN="Y"><LastName>Lettner</LastName>
<ForeName>Stefan</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y"><LastName>Gahleitner</LastName>
<ForeName>André</ForeName>
<Initials>A</Initials>
</Author>
<Author ValidYN="Y"><LastName>Zechner</LastName>
<ForeName>Werner</ForeName>
<Initials>W</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D023361">Validation Studies</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2013</Year>
<Month>05</Month>
<Day>16</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>United States</Country>
<MedlineTA>Clin Implant Dent Relat Res</MedlineTA>
<NlmUniqueID>100888977</NlmUniqueID>
<ISSNLinking>1523-0899</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D011140">Polyurethanes</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017267" MajorTopicYN="N">Dental Prosthesis Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D066298" MajorTopicYN="N">In Vitro Techniques</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D011140" MajorTopicYN="N">Polyurethanes</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D012984" MajorTopicYN="N">Software</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D025321" MajorTopicYN="Y">Surgery, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D016896" MajorTopicYN="N">Treatment Outcome</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM"><Keyword MajorTopicYN="N">computer-assisted</Keyword>
<Keyword MajorTopicYN="N">computerized tomography</Keyword>
<Keyword MajorTopicYN="N">flapless implant surgery</Keyword>
<Keyword MajorTopicYN="N">precision</Keyword>
<Keyword MajorTopicYN="N">stereo lithography</Keyword>
<Keyword MajorTopicYN="N">surgical guides</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="entrez"><Year>2013</Year>
<Month>5</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2013</Year>
<Month>5</Month>
<Day>18</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2016</Year>
<Month>12</Month>
<Day>15</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">23679124</ArticleId>
<ArticleId IdType="doi">10.1111/cid.12085</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000523 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000523 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:23679124 |texte= Evaluation of three different validation procedures regarding the accuracy of template-guided implant placement: an in vitro study. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:23679124" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |