Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture.
Identifieur interne : 000087 ( PubMed/Corpus ); précédent : 000086; suivant : 000088Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture.
Auteurs : Yoshiyuki Hagiwara ; Kiyoshi NakajimaSource :
- Journal of prosthodontic research [ 2212-4632 ] ; 2016.
English descriptors
- KwdEn :
- Aged, Aluminum Oxide, Cerium, Computer-Aided Design, Dental Materials, Dental Prosthesis, Implant-Supported (methods), Denture Design (methods), Denture, Complete, Humans, Jaw, Edentulous (psychology), Jaw, Edentulous (rehabilitation), Male, Mandible, Maxilla, Nanocomposites, Patient Satisfaction, Zirconium.
- MESH :
- chemical : Aluminum Oxide, Cerium, Dental Materials, Zirconium.
- methods : Dental Prosthesis, Implant-Supported, Denture Design.
- psychology : Jaw, Edentulous.
- rehabilitation : Jaw, Edentulous.
- Aged, Computer-Aided Design, Denture, Complete, Humans, Male, Mandible, Maxilla, Nanocomposites, Patient Satisfaction.
Abstract
A 69-year-old Japanese male visited Nihon University Dental Hospital for refabrication of his mandibular implant-supported complete fixed prosthesis (ISCFPD) and maxillary complete denture, which had been fabricated 15 years previously. In this case, Ce-TZP/Al2O3 nanocomposite (Ce-TZP/A) was applied to the framework of the mandibular ISCFPD and maxillary complete denture. Three years after deliver of the framework, no particularly notable biological or prosthetic complications were observed, and a high level of patient satisfaction had been achieved.
DOI: 10.1016/j.jpor.2016.02.002
PubMed: 26944223
Links to Exploration step
pubmed:26944223Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture.</title>
<author><name sortKey="Hagiwara, Yoshiyuki" sort="Hagiwara, Yoshiyuki" uniqKey="Hagiwara Y" first="Yoshiyuki" last="Hagiwara">Yoshiyuki Hagiwara</name>
<affiliation><nlm:affiliation>Department of Fixed Prosthodontics, Nihon University School of Dentistry, Toyo, Japan. Electronic address: hagiwara.yoshiyuki@nihon-u.ac.jp.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Nakajima, Kiyoshi" sort="Nakajima, Kiyoshi" uniqKey="Nakajima K" first="Kiyoshi" last="Nakajima">Kiyoshi Nakajima</name>
<affiliation><nlm:affiliation>KN Dental Laboratory, Hitachi City, Japan. Electronic address: knd-knd@memoad.jp.</nlm:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2016">2016</date>
<idno type="RBID">pubmed:26944223</idno>
<idno type="pmid">26944223</idno>
<idno type="doi">10.1016/j.jpor.2016.02.002</idno>
<idno type="wicri:Area/PubMed/Corpus">000087</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000087</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture.</title>
<author><name sortKey="Hagiwara, Yoshiyuki" sort="Hagiwara, Yoshiyuki" uniqKey="Hagiwara Y" first="Yoshiyuki" last="Hagiwara">Yoshiyuki Hagiwara</name>
<affiliation><nlm:affiliation>Department of Fixed Prosthodontics, Nihon University School of Dentistry, Toyo, Japan. Electronic address: hagiwara.yoshiyuki@nihon-u.ac.jp.</nlm:affiliation>
</affiliation>
</author>
<author><name sortKey="Nakajima, Kiyoshi" sort="Nakajima, Kiyoshi" uniqKey="Nakajima K" first="Kiyoshi" last="Nakajima">Kiyoshi Nakajima</name>
<affiliation><nlm:affiliation>KN Dental Laboratory, Hitachi City, Japan. Electronic address: knd-knd@memoad.jp.</nlm:affiliation>
</affiliation>
</author>
</analytic>
<series><title level="j">Journal of prosthodontic research</title>
<idno type="eISSN">2212-4632</idno>
<imprint><date when="2016" type="published">2016</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Aluminum Oxide</term>
<term>Cerium</term>
<term>Computer-Aided Design</term>
<term>Dental Materials</term>
<term>Dental Prosthesis, Implant-Supported (methods)</term>
<term>Denture Design (methods)</term>
<term>Denture, Complete</term>
<term>Humans</term>
<term>Jaw, Edentulous (psychology)</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Male</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Nanocomposites</term>
<term>Patient Satisfaction</term>
<term>Zirconium</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Aluminum Oxide</term>
<term>Cerium</term>
<term>Dental Materials</term>
<term>Zirconium</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Dental Prosthesis, Implant-Supported</term>
<term>Denture Design</term>
</keywords>
<keywords scheme="MESH" qualifier="psychology" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en"><term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Computer-Aided Design</term>
<term>Denture, Complete</term>
<term>Humans</term>
<term>Male</term>
<term>Mandible</term>
<term>Maxilla</term>
<term>Nanocomposites</term>
<term>Patient Satisfaction</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A 69-year-old Japanese male visited Nihon University Dental Hospital for refabrication of his mandibular implant-supported complete fixed prosthesis (ISCFPD) and maxillary complete denture, which had been fabricated 15 years previously. In this case, Ce-TZP/Al2O3 nanocomposite (Ce-TZP/A) was applied to the framework of the mandibular ISCFPD and maxillary complete denture. Three years after deliver of the framework, no particularly notable biological or prosthetic complications were observed, and a high level of patient satisfaction had been achieved.</div>
</front>
</TEI>
<pubmed><MedlineCitation Status="MEDLINE" Owner="NLM"><PMID Version="1">26944223</PMID>
<DateCompleted><Year>2017</Year>
<Month>07</Month>
<Day>28</Day>
</DateCompleted>
<DateRevised><Year>2017</Year>
<Month>07</Month>
<Day>28</Day>
</DateRevised>
<Article PubModel="Print-Electronic"><Journal><ISSN IssnType="Electronic">2212-4632</ISSN>
<JournalIssue CitedMedium="Internet"><Volume>60</Volume>
<Issue>4</Issue>
<PubDate><Year>2016</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Journal of prosthodontic research</Title>
<ISOAbbreviation>J Prosthodont Res</ISOAbbreviation>
</Journal>
<ArticleTitle>Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture.</ArticleTitle>
<Pagination><MedlinePgn>337-343</MedlinePgn>
</Pagination>
<ELocationID EIdType="pii" ValidYN="Y">S1883-1958(16)00018-9</ELocationID>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jpor.2016.02.002</ELocationID>
<Abstract><AbstractText Label="PATIENT" NlmCategory="METHODS">A 69-year-old Japanese male visited Nihon University Dental Hospital for refabrication of his mandibular implant-supported complete fixed prosthesis (ISCFPD) and maxillary complete denture, which had been fabricated 15 years previously. In this case, Ce-TZP/Al2O3 nanocomposite (Ce-TZP/A) was applied to the framework of the mandibular ISCFPD and maxillary complete denture. Three years after deliver of the framework, no particularly notable biological or prosthetic complications were observed, and a high level of patient satisfaction had been achieved.</AbstractText>
<AbstractText Label="DISCUSSION" NlmCategory="CONCLUSIONS">Conventional ISCFPD frameworks were fabricated by casting gold alloys; however, with the recent advancement of CAD/CAM technology, titanium (Ti) or yttria tetragonal zirconia polycrystal (Y-TZP) frameworks have become more common. In contrast, the main fabrication method for Ti or Co-Cr frameworks of removable dental prostheses has shifted from the conventional casting method to CAD/CAM fabrication. Ce-TZP/A, which was chosen as the framework material this time, shows higher strength and greater toughness than Y-TZP. However, since it has a low light-transmitting property and exhibits an opaque white color, the range of its application in fixed prostheses, particularly in the esthetic area, is limited.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">We described a case in which Ce-TZP/A was applied to the frameworks of a mandibular ISCFPD and a maxillary complete denture. No particularly notable biological or prosthetic complications were observed in the mandibular ISCFPD or the maxillary complete denture, and a high level of patient satisfaction was achieved. Medium- and long-term observations with a greater number of cases are essential to obtain information concerning various phenomena related to this procedure.</AbstractText>
<CopyrightInformation>Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.</CopyrightInformation>
</Abstract>
<AuthorList CompleteYN="Y"><Author ValidYN="Y"><LastName>Hagiwara</LastName>
<ForeName>Yoshiyuki</ForeName>
<Initials>Y</Initials>
<AffiliationInfo><Affiliation>Department of Fixed Prosthodontics, Nihon University School of Dentistry, Toyo, Japan. Electronic address: hagiwara.yoshiyuki@nihon-u.ac.jp.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y"><LastName>Nakajima</LastName>
<ForeName>Kiyoshi</ForeName>
<Initials>K</Initials>
<AffiliationInfo><Affiliation>KN Dental Laboratory, Hitachi City, Japan. Electronic address: knd-knd@memoad.jp.</Affiliation>
</AffiliationInfo>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList><PublicationType UI="D002363">Case Reports</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
<ArticleDate DateType="Electronic"><Year>2016</Year>
<Month>03</Month>
<Day>02</Day>
</ArticleDate>
</Article>
<MedlineJournalInfo><Country>Netherlands</Country>
<MedlineTA>J Prosthodont Res</MedlineTA>
<NlmUniqueID>101490359</NlmUniqueID>
<ISSNLinking>1883-1958</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList><Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="C475766">Ce-TZP-Al2O3</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003764">Dental Materials</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>30K4522N6T</RegistryNumber>
<NameOfSubstance UI="D002563">Cerium</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>C6V6S92N3C</RegistryNumber>
<NameOfSubstance UI="D015040">Zirconium</NameOfSubstance>
</Chemical>
<Chemical><RegistryNumber>LMI26O6933</RegistryNumber>
<NameOfSubstance UI="D000537">Aluminum Oxide</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList><MeshHeading><DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D000537" MajorTopicYN="Y">Aluminum Oxide</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D002563" MajorTopicYN="Y">Cerium</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017076" MajorTopicYN="Y">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003764" MajorTopicYN="Y">Dental Materials</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D019094" MajorTopicYN="N">Dental Prosthesis, Implant-Supported</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D003824" MajorTopicYN="Y">Denture, Complete</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000523" MajorTopicYN="N">psychology</QualifierName>
<QualifierName UI="Q000534" MajorTopicYN="Y">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D008437" MajorTopicYN="N">Maxilla</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D053761" MajorTopicYN="Y">Nanocomposites</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D017060" MajorTopicYN="N">Patient Satisfaction</DescriptorName>
</MeshHeading>
<MeshHeading><DescriptorName UI="D015040" MajorTopicYN="Y">Zirconium</DescriptorName>
</MeshHeading>
</MeshHeadingList>
<KeywordList Owner="NOTNLM"><Keyword MajorTopicYN="N">Ceria-stabilized zirconia/alumina nanocomposite</Keyword>
<Keyword MajorTopicYN="N">Complete denture framework</Keyword>
<Keyword MajorTopicYN="N">Computer-aided design/computer-aided manufacturing</Keyword>
<Keyword MajorTopicYN="N">Implant-supported complete fixed prostheses</Keyword>
<Keyword MajorTopicYN="N">Implant-supported complete fixed prostheses removable dental prosthesis</Keyword>
<Keyword MajorTopicYN="N">Removable dental prosthesis</Keyword>
</KeywordList>
</MedlineCitation>
<PubmedData><History><PubMedPubDate PubStatus="received"><Year>2015</Year>
<Month>11</Month>
<Day>26</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised"><Year>2016</Year>
<Month>01</Month>
<Day>29</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted"><Year>2016</Year>
<Month>02</Month>
<Day>12</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed"><Year>2016</Year>
<Month>10</Month>
<Day>25</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline"><Year>2017</Year>
<Month>7</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez"><Year>2016</Year>
<Month>3</Month>
<Day>6</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList><ArticleId IdType="pubmed">26944223</ArticleId>
<ArticleId IdType="pii">S1883-1958(16)00018-9</ArticleId>
<ArticleId IdType="doi">10.1016/j.jpor.2016.02.002</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000087 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000087 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Santé |area= EdenteV2 |flux= PubMed |étape= Corpus |type= RBID |clé= pubmed:26944223 |texte= Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i -Sk "pubmed:26944223" \ | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd \ | NlmPubMed2Wicri -a EdenteV2
This area was generated with Dilib version V0.6.32. |