Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.

Identifieur interne : 000006 ( PubMed/Corpus ); précédent : 000005; suivant : 000007

Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.

Auteurs : Su-Jung Park ; Richard Leesungbok ; Taixing Cui ; Suk Won Lee ; Su-Jin Ahn

Source :

RBID : pubmed:28697207

English descriptors

Abstract

This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site.

PubMed: 28697207

Links to Exploration step

pubmed:28697207

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.</title>
<author>
<name sortKey="Park, Su Jung" sort="Park, Su Jung" uniqKey="Park S" first="Su-Jung" last="Park">Su-Jung Park</name>
</author>
<author>
<name sortKey="Leesungbok, Richard" sort="Leesungbok, Richard" uniqKey="Leesungbok R" first="Richard" last="Leesungbok">Richard Leesungbok</name>
</author>
<author>
<name sortKey="Cui, Taixing" sort="Cui, Taixing" uniqKey="Cui T" first="Taixing" last="Cui">Taixing Cui</name>
</author>
<author>
<name sortKey="Lee, Suk Won" sort="Lee, Suk Won" uniqKey="Lee S" first="Suk Won" last="Lee">Suk Won Lee</name>
</author>
<author>
<name sortKey="Ahn, Su Jin" sort="Ahn, Su Jin" uniqKey="Ahn S" first="Su-Jin" last="Ahn">Su-Jin Ahn</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2017 Jul/Aug</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:28697207</idno>
<idno type="pmid">28697207</idno>
<idno type="wicri:Area/PubMed/Corpus">000006</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000006</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.</title>
<author>
<name sortKey="Park, Su Jung" sort="Park, Su Jung" uniqKey="Park S" first="Su-Jung" last="Park">Su-Jung Park</name>
</author>
<author>
<name sortKey="Leesungbok, Richard" sort="Leesungbok, Richard" uniqKey="Leesungbok R" first="Richard" last="Leesungbok">Richard Leesungbok</name>
</author>
<author>
<name sortKey="Cui, Taixing" sort="Cui, Taixing" uniqKey="Cui T" first="Taixing" last="Cui">Taixing Cui</name>
</author>
<author>
<name sortKey="Lee, Suk Won" sort="Lee, Suk Won" uniqKey="Lee S" first="Suk Won" last="Lee">Suk Won Lee</name>
</author>
<author>
<name sortKey="Ahn, Su Jin" sort="Ahn, Su Jin" uniqKey="Ahn S" first="Su-Jin" last="Ahn">Su-Jin Ahn</name>
</author>
</analytic>
<series>
<title level="j">The International journal of prosthodontics</title>
<idno type="ISSN">0893-2174</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Clinical Competence</term>
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Jaw, Edentulous, Partially (surgery)</term>
<term>Mandible (surgery)</term>
<term>Patient Care Planning</term>
<term>Reproducibility of Results</term>
<term>Surgery, Computer-Assisted (methods)</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
<term>Surgery, Computer-Assisted</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Jaw, Edentulous, Partially</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Clinical Competence</term>
<term>Computer-Aided Design</term>
<term>Humans</term>
<term>In Vitro Techniques</term>
<term>Patient Care Planning</term>
<term>Reproducibility of Results</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">28697207</PMID>
<DateCompleted>
<Year>2017</Year>
<Month>09</Month>
<Day>13</Day>
</DateCompleted>
<DateRevised>
<Year>2017</Year>
<Month>09</Month>
<Day>13</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0893-2174</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>30</Volume>
<Issue>4</Issue>
<PubDate>
<MedlineDate>2017 Jul/Aug</MedlineDate>
</PubDate>
</JournalIssue>
<Title>The International journal of prosthodontics</Title>
<ISOAbbreviation>Int J Prosthodont</ISOAbbreviation>
</Journal>
<ArticleTitle>Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.</ArticleTitle>
<Pagination>
<MedlinePgn>367-169</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.11607/ijp.5179</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site.</AbstractText>
<AbstractText Label="MATERIALS AND METHODS" NlmCategory="METHODS">A stereolithographic surgical guide for epoxy resin mandibles with three edentulous molar sites was produced using a computer-aided design/computer-assisted manufacture (CAD/CAM) system. Two surgeons with and two surgeons without implant surgery experience placed implants in a model either using or not using the CAD/CAM surgical guide. Four groups were created: inexperienced surgeon without the guide (group 1); experienced surgeon without the guide (group 2); inexperienced surgeon with the guide (group 3); and experienced surgeon with the guide (group 4). Planned implants and placed implants were superimposed using digital software, and deviation parameters were calculated.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">There were no significant differences in any of the deviation parameters between the groups when using the surgical guide. With respect to the implant sites, there were no significant differences among the groups in any parameter.</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Use of the CAD/CAM surgical guide reduced discrepancies among operators performing implant surgery regardless of their level of experience. Whether or not the guide was used, differences in the anterior-posterior implant site in the molar area did not affect the accuracy of implant placement.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Park</LastName>
<ForeName>Su-Jung</ForeName>
<Initials>SJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Leesungbok</LastName>
<ForeName>Richard</ForeName>
<Initials>R</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Cui</LastName>
<ForeName>Taixing</ForeName>
<Initials>T</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lee</LastName>
<ForeName>Suk Won</ForeName>
<Initials>SW</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Ahn</LastName>
<ForeName>Su-Jin</ForeName>
<Initials>SJ</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>Int J Prosthodont</MedlineTA>
<NlmUniqueID>8900938</NlmUniqueID>
<ISSNLinking>0893-2174</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D002983" MajorTopicYN="Y">Clinical Competence</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="Y">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D066298" MajorTopicYN="N">In Vitro Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007576" MajorTopicYN="N">Jaw, Edentulous, Partially</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D010347" MajorTopicYN="N">Patient Care Planning</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="N">Surgery, Computer-Assisted</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2017</Year>
<Month>7</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2017</Year>
<Month>7</Month>
<Day>12</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2017</Year>
<Month>9</Month>
<Day>14</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">28697207</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000006 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd -nk 000006 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Corpus
   |type=    RBID
   |clé=     pubmed:28697207
   |texte=   Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Corpus/RBID.i   -Sk "pubmed:28697207" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022