Serveur d'exploration sur le patient édenté

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.

Identifieur interne : 003867 ( PubMed/Checkpoint ); précédent : 003866; suivant : 003868

Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.

Auteurs : A R Ogden [Royaume-Uni] ; A A Siddiqui ; R M Basker

Source :

RBID : pubmed:8186041

Descripteurs français

English descriptors

Abstract

This study compares the sizes of patients' edentulous arches with the shapes of a range of disposable stock trays from one manufacturer. In many dimensions there is considerable discrepancy between the two. It is concluded that, even with tray modification, it is almost impossible to obtain an accurate impression of the shape of the all-important sulcus regions. Such a conclusion emphasises the importance of obtaining further impressions in special trays which are modified appropriately.

PubMed: 8186041


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:8186041

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.</title>
<author>
<name sortKey="Ogden, A R" sort="Ogden, A R" uniqKey="Ogden A" first="A R" last="Ogden">A R Ogden</name>
<affiliation wicri:level="4">
<nlm:affiliation>Division of Restorative Dentistry, Leeds Dental Institute, University of Leeds.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<settlement type="city">Leeds</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Yorkshire-et-Humber</region>
</placeName>
<orgName type="university">Université de Leeds</orgName>
</affiliation>
</author>
<author>
<name sortKey="Siddiqui, A A" sort="Siddiqui, A A" uniqKey="Siddiqui A" first="A A" last="Siddiqui">A A Siddiqui</name>
</author>
<author>
<name sortKey="Basker, R M" sort="Basker, R M" uniqKey="Basker R" first="R M" last="Basker">R M Basker</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1994">1994</date>
<idno type="RBID">pubmed:8186041</idno>
<idno type="pmid">8186041</idno>
<idno type="wicri:Area/PubMed/Corpus">004455</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004455</idno>
<idno type="wicri:Area/PubMed/Curation">004455</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">004455</idno>
<idno type="wicri:Area/PubMed/Checkpoint">004455</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">004455</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.</title>
<author>
<name sortKey="Ogden, A R" sort="Ogden, A R" uniqKey="Ogden A" first="A R" last="Ogden">A R Ogden</name>
<affiliation wicri:level="4">
<nlm:affiliation>Division of Restorative Dentistry, Leeds Dental Institute, University of Leeds.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<settlement type="city">Leeds</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Yorkshire-et-Humber</region>
</placeName>
<orgName type="university">Université de Leeds</orgName>
</affiliation>
</author>
<author>
<name sortKey="Siddiqui, A A" sort="Siddiqui, A A" uniqKey="Siddiqui A" first="A A" last="Siddiqui">A A Siddiqui</name>
</author>
<author>
<name sortKey="Basker, R M" sort="Basker, R M" uniqKey="Basker R" first="R M" last="Basker">R M Basker</name>
</author>
</analytic>
<series>
<title level="j">British dental journal</title>
<idno type="ISSN">0007-0610</idno>
<imprint>
<date when="1994" type="published">1994</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Dental Impression Technique (instrumentation)</term>
<term>Dental Models (standards)</term>
<term>Denture Design (instrumentation)</term>
<term>Denture Design (standards)</term>
<term>Denture, Complete (standards)</term>
<term>Disposable Equipment</term>
<term>Equipment Design</term>
<term>Humans</term>
<term>Jaw, Edentulous (pathology)</term>
<term>Reproducibility of Results</term>
<term>Technology, Dental (instrumentation)</term>
<term>United Kingdom</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Conception d'appareil de prothèse dentaire (instrumentation)</term>
<term>Conception d'appareil de prothèse dentaire (normes)</term>
<term>Conception d'appareillage</term>
<term>Humains</term>
<term>Matériel jetable</term>
<term>Modèles dentaires (normes)</term>
<term>Mâchoire édentée (anatomopathologie)</term>
<term>Prothèse dentaire complète (normes)</term>
<term>Reproductibilité des résultats</term>
<term>Royaume-Uni</term>
<term>Technique de prise d'empreinte (instrumentation)</term>
<term>Technologie dentaire (instrumentation)</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomopathologie" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Dental Impression Technique</term>
<term>Denture Design</term>
<term>Technology, Dental</term>
</keywords>
<keywords scheme="MESH" qualifier="normes" xml:lang="fr">
<term>Conception d'appareil de prothèse dentaire</term>
<term>Modèles dentaires</term>
<term>Prothèse dentaire complète</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="standards" xml:lang="en">
<term>Dental Models</term>
<term>Denture Design</term>
<term>Denture, Complete</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Disposable Equipment</term>
<term>Equipment Design</term>
<term>Humans</term>
<term>Reproducibility of Results</term>
<term>United Kingdom</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="fr">
<term>Conception d'appareil de prothèse dentaire</term>
<term>Conception d'appareillage</term>
<term>Humains</term>
<term>Matériel jetable</term>
<term>Reproductibilité des résultats</term>
<term>Royaume-Uni</term>
<term>Technique de prise d'empreinte</term>
<term>Technologie dentaire</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This study compares the sizes of patients' edentulous arches with the shapes of a range of disposable stock trays from one manufacturer. In many dimensions there is considerable discrepancy between the two. It is concluded that, even with tray modification, it is almost impossible to obtain an accurate impression of the shape of the all-important sulcus regions. Such a conclusion emphasises the importance of obtaining further impressions in special trays which are modified appropriately.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">8186041</PMID>
<DateCompleted>
<Year>1994</Year>
<Month>06</Month>
<Day>23</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0007-0610</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>176</Volume>
<Issue>8</Issue>
<PubDate>
<Year>1994</Year>
<Month>Apr</Month>
<Day>23</Day>
</PubDate>
</JournalIssue>
<Title>British dental journal</Title>
<ISOAbbreviation>Br Dent J</ISOAbbreviation>
</Journal>
<ArticleTitle>Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.</ArticleTitle>
<Pagination>
<MedlinePgn>303-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>This study compares the sizes of patients' edentulous arches with the shapes of a range of disposable stock trays from one manufacturer. In many dimensions there is considerable discrepancy between the two. It is concluded that, even with tray modification, it is almost impossible to obtain an accurate impression of the shape of the all-important sulcus regions. Such a conclusion emphasises the importance of obtaining further impressions in special trays which are modified appropriately.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Ogden</LastName>
<ForeName>A R</ForeName>
<Initials>AR</Initials>
<AffiliationInfo>
<Affiliation>Division of Restorative Dentistry, Leeds Dental Institute, University of Leeds.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Siddiqui</LastName>
<ForeName>A A</ForeName>
<Initials>AA</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Basker</LastName>
<ForeName>R M</ForeName>
<Initials>RM</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>England</Country>
<MedlineTA>Br Dent J</MedlineTA>
<NlmUniqueID>7513219</NlmUniqueID>
<ISSNLinking>0007-0610</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D003761" MajorTopicYN="N">Dental Impression Technique</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003779" MajorTopicYN="N">Denture Design</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003824" MajorTopicYN="N">Denture, Complete</DescriptorName>
<QualifierName UI="Q000592" MajorTopicYN="Y">standards</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004209" MajorTopicYN="N">Disposable Equipment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004867" MajorTopicYN="N">Equipment Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000473" MajorTopicYN="Y">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015203" MajorTopicYN="N">Reproducibility of Results</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013674" MajorTopicYN="N">Technology, Dental</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="N">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006113" MajorTopicYN="N">United Kingdom</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1994</Year>
<Month>4</Month>
<Day>23</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1994</Year>
<Month>4</Month>
<Day>23</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1994</Year>
<Month>4</Month>
<Day>23</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8186041</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
<region>
<li>Angleterre</li>
<li>Yorkshire-et-Humber</li>
</region>
<settlement>
<li>Leeds</li>
</settlement>
<orgName>
<li>Université de Leeds</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="Basker, R M" sort="Basker, R M" uniqKey="Basker R" first="R M" last="Basker">R M Basker</name>
<name sortKey="Siddiqui, A A" sort="Siddiqui, A A" uniqKey="Siddiqui A" first="A A" last="Siddiqui">A A Siddiqui</name>
</noCountry>
<country name="Royaume-Uni">
<region name="Angleterre">
<name sortKey="Ogden, A R" sort="Ogden, A R" uniqKey="Ogden A" first="A R" last="Ogden">A R Ogden</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003867 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 003867 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:8186041
   |texte=   Disposable trays for complete denture construction: a dimensional study of a type frequently used in the UK and of its suitability for the edentulous population.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:8186041" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022