Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.

Identifieur interne : 003688 ( PubMed/Checkpoint ); précédent : 003687; suivant : 003689

Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.

Auteurs : R. Jacobs [Belgique] ; D. Van Steenberghe ; I. Naert

Source :

RBID : pubmed:7760279

Descripteurs français

English descriptors

Abstract

To establish whether different implant-supported prosthetic reconstructions influence jaw muscle resistance to clenching efforts, sustained submaximal (50%) clenching was performed in two groups of patients who were edentulous in one or both jaws. One group consisted of patients who were rehabilitated by means of an overdenture on two to four implants connected by a bar; the other group consisted of patients who were rehabilitated with an implant-supported fixed prosthesis on four to seven implants in either the maxilla or the mandible. Results indicated that after rehabilitation with implant-supported fixed reconstructions, the myoelectric output level increased over time, which was parallel to a higher bite force level. For the other group, such a time-dependent change in electromyographic amplitude did not occur. On the other hand, power spectrum analysis revealed a significant downward shift of the mean power frequency during sustained clenching after rehabilitation with implant-supported overdentures but not with implant-supported fixed prostheses. The absence of a spectral shift in the latter group probably expressed a fear of biting too hard and fracturing the prosthesis.

PubMed: 7760279


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:7760279

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.</title>
<author>
<name sortKey="Jacobs, R" sort="Jacobs, R" uniqKey="Jacobs R" first="R" last="Jacobs">R. Jacobs</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Periodontology, Faculty of Medicine, Catholic University of Leuven, Belgium.</nlm:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Department of Periodontology, Faculty of Medicine, Catholic University of Leuven</wicri:regionArea>
<wicri:noRegion>Catholic University of Leuven</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D" last="Van Steenberghe">D. Van Steenberghe</name>
</author>
<author>
<name sortKey="Naert, I" sort="Naert, I" uniqKey="Naert I" first="I" last="Naert">I. Naert</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:7760279</idno>
<idno type="pmid">7760279</idno>
<idno type="wicri:Area/PubMed/Corpus">004294</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">004294</idno>
<idno type="wicri:Area/PubMed/Curation">004294</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">004294</idno>
<idno type="wicri:Area/PubMed/Checkpoint">004294</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">004294</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.</title>
<author>
<name sortKey="Jacobs, R" sort="Jacobs, R" uniqKey="Jacobs R" first="R" last="Jacobs">R. Jacobs</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Periodontology, Faculty of Medicine, Catholic University of Leuven, Belgium.</nlm:affiliation>
<country xml:lang="fr">Belgique</country>
<wicri:regionArea>Department of Periodontology, Faculty of Medicine, Catholic University of Leuven</wicri:regionArea>
<wicri:noRegion>Catholic University of Leuven</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D" last="Van Steenberghe">D. Van Steenberghe</name>
</author>
<author>
<name sortKey="Naert, I" sort="Naert, I" uniqKey="Naert I" first="I" last="Naert">I. Naert</name>
</author>
</analytic>
<series>
<title level="j">The Journal of prosthetic dentistry</title>
<idno type="ISSN">0022-3913</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Bite Force</term>
<term>Dental Implants</term>
<term>Denture, Overlay</term>
<term>Denture, Partial, Fixed</term>
<term>Electromyography</term>
<term>Female</term>
<term>Humans</term>
<term>Infant, Newborn</term>
<term>Isometric Contraction</term>
<term>Jaw, Edentulous (rehabilitation)</term>
<term>Masseter Muscle (physiopathology)</term>
<term>Middle Aged</term>
<term>Muscle Fatigue</term>
<term>Regression Analysis</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Analyse de régression</term>
<term>Contraction isométrique</term>
<term>Fatigue musculaire</term>
<term>Femelle</term>
<term>Force occlusale</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Muscle masséter (physiopathologie)</term>
<term>Mâchoire édentée (rééducation et réadaptation)</term>
<term>Nouveau-né</term>
<term>Overdenture</term>
<term>Prothèse partielle fixe</term>
<term>Sujet âgé</term>
<term>Électromyographie</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Dental Implants</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Muscle masséter</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Masseter Muscle</term>
</keywords>
<keywords scheme="MESH" qualifier="rehabilitation" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="rééducation et réadaptation" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Bite Force</term>
<term>Denture, Overlay</term>
<term>Denture, Partial, Fixed</term>
<term>Electromyography</term>
<term>Female</term>
<term>Humans</term>
<term>Infant, Newborn</term>
<term>Isometric Contraction</term>
<term>Middle Aged</term>
<term>Muscle Fatigue</term>
<term>Regression Analysis</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Analyse de régression</term>
<term>Contraction isométrique</term>
<term>Fatigue musculaire</term>
<term>Femelle</term>
<term>Force occlusale</term>
<term>Humains</term>
<term>Implants dentaires</term>
<term>Nouveau-né</term>
<term>Overdenture</term>
<term>Prothèse partielle fixe</term>
<term>Sujet âgé</term>
<term>Électromyographie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To establish whether different implant-supported prosthetic reconstructions influence jaw muscle resistance to clenching efforts, sustained submaximal (50%) clenching was performed in two groups of patients who were edentulous in one or both jaws. One group consisted of patients who were rehabilitated by means of an overdenture on two to four implants connected by a bar; the other group consisted of patients who were rehabilitated with an implant-supported fixed prosthesis on four to seven implants in either the maxilla or the mandible. Results indicated that after rehabilitation with implant-supported fixed reconstructions, the myoelectric output level increased over time, which was parallel to a higher bite force level. For the other group, such a time-dependent change in electromyographic amplitude did not occur. On the other hand, power spectrum analysis revealed a significant downward shift of the mean power frequency during sustained clenching after rehabilitation with implant-supported overdentures but not with implant-supported fixed prostheses. The absence of a spectral shift in the latter group probably expressed a fear of biting too hard and fracturing the prosthesis.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">7760279</PMID>
<DateCompleted>
<Year>1995</Year>
<Month>06</Month>
<Day>27</Day>
</DateCompleted>
<DateRevised>
<Year>2006</Year>
<Month>11</Month>
<Day>15</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0022-3913</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>73</Volume>
<Issue>3</Issue>
<PubDate>
<Year>1995</Year>
<Month>Mar</Month>
</PubDate>
</JournalIssue>
<Title>The Journal of prosthetic dentistry</Title>
<ISOAbbreviation>J Prosthet Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.</ArticleTitle>
<Pagination>
<MedlinePgn>284-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>To establish whether different implant-supported prosthetic reconstructions influence jaw muscle resistance to clenching efforts, sustained submaximal (50%) clenching was performed in two groups of patients who were edentulous in one or both jaws. One group consisted of patients who were rehabilitated by means of an overdenture on two to four implants connected by a bar; the other group consisted of patients who were rehabilitated with an implant-supported fixed prosthesis on four to seven implants in either the maxilla or the mandible. Results indicated that after rehabilitation with implant-supported fixed reconstructions, the myoelectric output level increased over time, which was parallel to a higher bite force level. For the other group, such a time-dependent change in electromyographic amplitude did not occur. On the other hand, power spectrum analysis revealed a significant downward shift of the mean power frequency during sustained clenching after rehabilitation with implant-supported overdentures but not with implant-supported fixed prostheses. The absence of a spectral shift in the latter group probably expressed a fear of biting too hard and fracturing the prosthesis.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Jacobs</LastName>
<ForeName>R</ForeName>
<Initials>R</Initials>
<AffiliationInfo>
<Affiliation>Department of Periodontology, Faculty of Medicine, Catholic University of Leuven, Belgium.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>van Steenberghe</LastName>
<ForeName>D</ForeName>
<Initials>D</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Naert</LastName>
<ForeName>I</ForeName>
<Initials>I</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Prosthet Dent</MedlineTA>
<NlmUniqueID>0376364</NlmUniqueID>
<ISSNLinking>0022-3913</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000368" MajorTopicYN="N">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001732" MajorTopicYN="Y">Bite Force</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003830" MajorTopicYN="Y">Denture, Partial, Fixed</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004576" MajorTopicYN="N">Electromyography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007231" MajorTopicYN="N">Infant, Newborn</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007537" MajorTopicYN="N">Isometric Contraction</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000534" MajorTopicYN="N">rehabilitation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008406" MajorTopicYN="N">Masseter Muscle</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="Y">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D018763" MajorTopicYN="N">Muscle Fatigue</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D012044" MajorTopicYN="N">Regression Analysis</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>3</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>3</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">7760279</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Belgique</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Naert, I" sort="Naert, I" uniqKey="Naert I" first="I" last="Naert">I. Naert</name>
<name sortKey="Van Steenberghe, D" sort="Van Steenberghe, D" uniqKey="Van Steenberghe D" first="D" last="Van Steenberghe">D. Van Steenberghe</name>
</noCountry>
<country name="Belgique">
<noRegion>
<name sortKey="Jacobs, R" sort="Jacobs, R" uniqKey="Jacobs R" first="R" last="Jacobs">R. Jacobs</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003688 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 003688 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:7760279
   |texte=   Masseter muscle fatigue before and after rehabilitation with implant-supported prostheses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:7760279" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022