Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.

Identifieur interne : 001898 ( PubMed/Checkpoint ); précédent : 001897; suivant : 001899

Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.

Auteurs : Chanseop Park [États-Unis] ; Ariel J. Raigrodski ; Jacob Rosen ; Charles Spiekerman ; Robert M. London

Source :

RBID : pubmed:19463664

Descripteurs français

English descriptors

Abstract

Surgical guides may interfere with effective use of surgical instrumentation during implant placement in the posterior segments where interocclusal distance may be limited.

DOI: 10.1016/S0022-3913(09)60080-9
PubMed: 19463664


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:19463664

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.</title>
<author>
<name sortKey="Park, Chanseop" sort="Park, Chanseop" uniqKey="Park C" first="Chanseop" last="Park">Chanseop Park</name>
<affiliation wicri:level="4">
<nlm:affiliation>Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195</wicri:regionArea>
<orgName type="university">Université de Washington</orgName>
<placeName>
<settlement type="city">Seattle</settlement>
<region type="state">Washington (État)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Raigrodski, Ariel J" sort="Raigrodski, Ariel J" uniqKey="Raigrodski A" first="Ariel J" last="Raigrodski">Ariel J. Raigrodski</name>
</author>
<author>
<name sortKey="Rosen, Jacob" sort="Rosen, Jacob" uniqKey="Rosen J" first="Jacob" last="Rosen">Jacob Rosen</name>
</author>
<author>
<name sortKey="Spiekerman, Charles" sort="Spiekerman, Charles" uniqKey="Spiekerman C" first="Charles" last="Spiekerman">Charles Spiekerman</name>
</author>
<author>
<name sortKey="London, Robert M" sort="London, Robert M" uniqKey="London R" first="Robert M" last="London">Robert M. London</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="RBID">pubmed:19463664</idno>
<idno type="pmid">19463664</idno>
<idno type="doi">10.1016/S0022-3913(09)60080-9</idno>
<idno type="wicri:Area/PubMed/Corpus">001D14</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">001D14</idno>
<idno type="wicri:Area/PubMed/Curation">001D14</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">001D14</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001D14</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">001D14</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.</title>
<author>
<name sortKey="Park, Chanseop" sort="Park, Chanseop" uniqKey="Park C" first="Chanseop" last="Park">Chanseop Park</name>
<affiliation wicri:level="4">
<nlm:affiliation>Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195</wicri:regionArea>
<orgName type="university">Université de Washington</orgName>
<placeName>
<settlement type="city">Seattle</settlement>
<region type="state">Washington (État)</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Raigrodski, Ariel J" sort="Raigrodski, Ariel J" uniqKey="Raigrodski A" first="Ariel J" last="Raigrodski">Ariel J. Raigrodski</name>
</author>
<author>
<name sortKey="Rosen, Jacob" sort="Rosen, Jacob" uniqKey="Rosen J" first="Jacob" last="Rosen">Jacob Rosen</name>
</author>
<author>
<name sortKey="Spiekerman, Charles" sort="Spiekerman, Charles" uniqKey="Spiekerman C" first="Charles" last="Spiekerman">Charles Spiekerman</name>
</author>
<author>
<name sortKey="London, Robert M" sort="London, Robert M" uniqKey="London R" first="Robert M" last="London">Robert M. London</name>
</author>
</analytic>
<series>
<title level="j">The Journal of prosthetic dentistry</title>
<idno type="eISSN">1097-6841</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Implantation, Endosseous (methods)</term>
<term>Dental Models</term>
<term>Equipment Design (statistics & numerical data)</term>
<term>Humans</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Mandible (surgery)</term>
<term>Manikins</term>
<term>Models, Anatomic</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted</term>
<term>Torque</term>
<term>User-Computer Interface</term>
<term>Vertical Dimension</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Chirurgie assistée par ordinateur</term>
<term>Conception assistée par ordinateur</term>
<term>Conception d'appareillage ()</term>
<term>Dimension verticale</term>
<term>Humains</term>
<term>Interface utilisateur</term>
<term>Mandibule ()</term>
<term>Mannequins</term>
<term>Modèles anatomiques</term>
<term>Modèles dentaires</term>
<term>Moment de torsion</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Pose d'implant dentaire endo-osseux ()</term>
<term>Radiographie</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Dental Implantation, Endosseous</term>
</keywords>
<keywords scheme="MESH" qualifier="statistics & numerical data" xml:lang="en">
<term>Equipment Design</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer-Aided Design</term>
<term>Dental Models</term>
<term>Humans</term>
<term>Manikins</term>
<term>Models, Anatomic</term>
<term>Radiography</term>
<term>Surgery, Computer-Assisted</term>
<term>Torque</term>
<term>User-Computer Interface</term>
<term>Vertical Dimension</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Chirurgie assistée par ordinateur</term>
<term>Conception assistée par ordinateur</term>
<term>Conception d'appareillage</term>
<term>Dimension verticale</term>
<term>Humains</term>
<term>Interface utilisateur</term>
<term>Mandibule</term>
<term>Mannequins</term>
<term>Modèles anatomiques</term>
<term>Modèles dentaires</term>
<term>Moment de torsion</term>
<term>Pose d'implant dentaire endo-osseux</term>
<term>Radiographie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Surgical guides may interfere with effective use of surgical instrumentation during implant placement in the posterior segments where interocclusal distance may be limited.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">19463664</PMID>
<DateCompleted>
<Year>2009</Year>
<Month>08</Month>
<Day>10</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1097-6841</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>101</Volume>
<Issue>6</Issue>
<PubDate>
<Year>2009</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>The Journal of prosthetic dentistry</Title>
<ISOAbbreviation>J Prosthet Dent</ISOAbbreviation>
</Journal>
<ArticleTitle>Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.</ArticleTitle>
<Pagination>
<MedlinePgn>372-81</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/S0022-3913(09)60080-9</ELocationID>
<Abstract>
<AbstractText Label="STATEMENT OF PROBLEM" NlmCategory="BACKGROUND">Surgical guides may interfere with effective use of surgical instrumentation during implant placement in the posterior segments where interocclusal distance may be limited.</AbstractText>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">The purpose of this study was to measure and compare the accuracy of posterior implant placement using 3 precision surgical guides with varying occlusogingival heights, and to evaluate the difference in accuracy of implant placement through precision guides as compared to freehand placement.</AbstractText>
<AbstractText Label="MATERIAL AND METHODS" NlmCategory="METHODS">Three groups of surgical guides were fabricated with occlusogingival heights of 4, 6, and 8 mm, respectively. A jig was fabricated to allow for accurate positioning in bone substitute blocks. Ninety implants were placed in the mandibular first molar site on a manikin. Thirty implants (Astra Tech AB) were placed for each group, with 15 through the guide and 15 freehand. Distances between a reference implant and each placed implant were measured at both implant and abutment levels using a coordinate measuring machine. Apex position and angular discrepancy were calculated using the coordinates of the centers of the implant platform and of the occlusal aspect of the abutment. Data was assessed using 2-way ANOVA (alpha=.05).</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Two-way ANOVA demonstrated that guide height did not significantly affect the accuracy of the implant position. The distance from the reference point to the point of measurement was significantly smaller for placement through the guide compared to freehand placement at both implant (P<.001) and abutment levels (P<.001). The angular discrepancy was also significantly smaller for placement through the guide (P<.001).</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Precision surgical guides with 4-mm occlusogingival height allow placement as accurate as precision guides with 8-mm height. Placement through the guide reproduced the target position more accurately than freehand insertion.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Park</LastName>
<ForeName>Chanseop</ForeName>
<Initials>C</Initials>
<AffiliationInfo>
<Affiliation>Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195, USA.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Raigrodski</LastName>
<ForeName>Ariel J</ForeName>
<Initials>AJ</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Rosen</LastName>
<ForeName>Jacob</ForeName>
<Initials>J</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Spiekerman</LastName>
<ForeName>Charles</ForeName>
<Initials>C</Initials>
</Author>
<Author ValidYN="Y">
<LastName>London</LastName>
<ForeName>Robert M</ForeName>
<Initials>RM</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D023362">Evaluation Studies</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Prosthet Dent</MedlineTA>
<NlmUniqueID>0376364</NlmUniqueID>
<ISSNLinking>0022-3913</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D017076" MajorTopicYN="N">Computer-Aided Design</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003758" MajorTopicYN="N">Dental Implantation, Endosseous</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003765" MajorTopicYN="N">Dental Models</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D004867" MajorTopicYN="N">Equipment Design</DescriptorName>
<QualifierName UI="Q000706" MajorTopicYN="N">statistics & numerical data</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000601" MajorTopicYN="Y">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008348" MajorTopicYN="N">Manikins</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008953" MajorTopicYN="Y">Models, Anatomic</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D025321" MajorTopicYN="Y">Surgery, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019415" MajorTopicYN="N">Torque</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014584" MajorTopicYN="Y">User-Computer Interface</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014716" MajorTopicYN="N">Vertical Dimension</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2009</Year>
<Month>5</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2009</Year>
<Month>5</Month>
<Day>26</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2009</Year>
<Month>8</Month>
<Day>11</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">19463664</ArticleId>
<ArticleId IdType="pii">S0022-3913(09)60080-9</ArticleId>
<ArticleId IdType="doi">10.1016/S0022-3913(09)60080-9</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Washington (État)</li>
</region>
<settlement>
<li>Seattle</li>
</settlement>
<orgName>
<li>Université de Washington</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="London, Robert M" sort="London, Robert M" uniqKey="London R" first="Robert M" last="London">Robert M. London</name>
<name sortKey="Raigrodski, Ariel J" sort="Raigrodski, Ariel J" uniqKey="Raigrodski A" first="Ariel J" last="Raigrodski">Ariel J. Raigrodski</name>
<name sortKey="Rosen, Jacob" sort="Rosen, Jacob" uniqKey="Rosen J" first="Jacob" last="Rosen">Jacob Rosen</name>
<name sortKey="Spiekerman, Charles" sort="Spiekerman, Charles" uniqKey="Spiekerman C" first="Charles" last="Spiekerman">Charles Spiekerman</name>
</noCountry>
<country name="États-Unis">
<region name="Washington (État)">
<name sortKey="Park, Chanseop" sort="Park, Chanseop" uniqKey="Park C" first="Chanseop" last="Park">Chanseop Park</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001898 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 001898 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:19463664
   |texte=   Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:19463664" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022