The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.

Identifieur interne : 000890 ( PubMed/Checkpoint ); précédent : 000889; suivant : 000891

The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.

Auteurs : Mohammad Hossein Dashti [États-Unis] ; Parsa Atashrazm ; Mehdi Imani Emadi ; Shiva Mishaeel ; Sepideh Banava

Source :

RBID : pubmed:23757462

Descripteurs français

English descriptors

Abstract

Two commonly used attachment systems for implant-retained overdentures are bar and ball systems. The aim of this study was to compare these two types of attachments on the basis of the stresses introduced to the mandibular posterior residual ridge by an overdenture retained by two implants.

DOI: 10.3290/j.qi.a29753
PubMed: 23757462


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:23757462

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.</title>
<author>
<name sortKey="Dashti, Mohammad Hossein" sort="Dashti, Mohammad Hossein" uniqKey="Dashti M" first="Mohammad Hossein" last="Dashti">Mohammad Hossein Dashti</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department Prosthodontics, Boston University School of Dental Medicine, Boston, MA 02118, USA. mhdashti@bu.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department Prosthodontics, Boston University School of Dental Medicine, Boston, MA 02118</wicri:regionArea>
<wicri:noRegion>MA 02118</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Atashrazm, Parsa" sort="Atashrazm, Parsa" uniqKey="Atashrazm P" first="Parsa" last="Atashrazm">Parsa Atashrazm</name>
</author>
<author>
<name sortKey="Emadi, Mehdi Imani" sort="Emadi, Mehdi Imani" uniqKey="Emadi M" first="Mehdi Imani" last="Emadi">Mehdi Imani Emadi</name>
</author>
<author>
<name sortKey="Mishaeel, Shiva" sort="Mishaeel, Shiva" uniqKey="Mishaeel S" first="Shiva" last="Mishaeel">Shiva Mishaeel</name>
</author>
<author>
<name sortKey="Banava, Sepideh" sort="Banava, Sepideh" uniqKey="Banava S" first="Sepideh" last="Banava">Sepideh Banava</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2013">2013</date>
<idno type="RBID">pubmed:23757462</idno>
<idno type="pmid">23757462</idno>
<idno type="doi">10.3290/j.qi.a29753</idno>
<idno type="wicri:Area/PubMed/Corpus">000E26</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Corpus" wicri:corpus="PubMed">000E26</idno>
<idno type="wicri:Area/PubMed/Curation">000E26</idno>
<idno type="wicri:explorRef" wicri:stream="PubMed" wicri:step="Curation">000E26</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000E26</idno>
<idno type="wicri:explorRef" wicri:stream="Checkpoint" wicri:step="PubMed">000E26</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.</title>
<author>
<name sortKey="Dashti, Mohammad Hossein" sort="Dashti, Mohammad Hossein" uniqKey="Dashti M" first="Mohammad Hossein" last="Dashti">Mohammad Hossein Dashti</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department Prosthodontics, Boston University School of Dental Medicine, Boston, MA 02118, USA. mhdashti@bu.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department Prosthodontics, Boston University School of Dental Medicine, Boston, MA 02118</wicri:regionArea>
<wicri:noRegion>MA 02118</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Atashrazm, Parsa" sort="Atashrazm, Parsa" uniqKey="Atashrazm P" first="Parsa" last="Atashrazm">Parsa Atashrazm</name>
</author>
<author>
<name sortKey="Emadi, Mehdi Imani" sort="Emadi, Mehdi Imani" uniqKey="Emadi M" first="Mehdi Imani" last="Emadi">Mehdi Imani Emadi</name>
</author>
<author>
<name sortKey="Mishaeel, Shiva" sort="Mishaeel, Shiva" uniqKey="Mishaeel S" first="Shiva" last="Mishaeel">Shiva Mishaeel</name>
</author>
<author>
<name sortKey="Banava, Sepideh" sort="Banava, Sepideh" uniqKey="Banava S" first="Sepideh" last="Banava">Sepideh Banava</name>
</author>
</analytic>
<series>
<title level="j">Quintessence international (Berlin, Germany : 1985)</title>
<idno type="eISSN">1936-7163</idno>
<imprint>
<date when="2013" type="published">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic Resins (chemistry)</term>
<term>Biomechanical Phenomena</term>
<term>Bite Force</term>
<term>Computer Simulation</term>
<term>Dental Abutments</term>
<term>Dental Arch (physiology)</term>
<term>Dental Implants</term>
<term>Dental Materials (chemistry)</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture Retention (instrumentation)</term>
<term>Denture, Complete, Lower</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Finite Element Analysis</term>
<term>Gold Alloys (chemistry)</term>
<term>Humans</term>
<term>Imaging, Three-Dimensional (methods)</term>
<term>Jaw, Edentulous (diagnostic imaging)</term>
<term>Jaw, Edentulous (physiopathology)</term>
<term>Mandible (diagnostic imaging)</term>
<term>Mandible (physiology)</term>
<term>Middle Aged</term>
<term>Models, Biological</term>
<term>Stress, Mechanical</term>
<term>Titanium (chemistry)</term>
<term>Tomography, X-Ray Computed (methods)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Alliages d'or ()</term>
<term>Analyse des éléments finis</term>
<term>Arcade dentaire (physiologie)</term>
<term>Contrainte mécanique</term>
<term>Femelle</term>
<term>Force occlusale</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle ()</term>
<term>Implants dentaires</term>
<term>Mandibule (imagerie diagnostique)</term>
<term>Mandibule (physiologie)</term>
<term>Matériaux dentaires ()</term>
<term>Modèles biologiques</term>
<term>Mâchoire édentée (imagerie diagnostique)</term>
<term>Mâchoire édentée (physiopathologie)</term>
<term>Overdenture</term>
<term>Phénomènes biomécaniques</term>
<term>Piliers dentaires</term>
<term>Prothèse dentaire complète inférieure</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Résines acryliques ()</term>
<term>Rétention d'appareil de prothèse dentaire (instrumentation)</term>
<term>Simulation numérique</term>
<term>Titane ()</term>
<term>Tomodensitométrie ()</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="chemistry" xml:lang="en">
<term>Acrylic Resins</term>
<term>Dental Materials</term>
<term>Gold Alloys</term>
<term>Titanium</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw, Edentulous</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mandibule</term>
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Denture Retention</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Imaging, Three-Dimensional</term>
<term>Tomography, X-Ray Computed</term>
</keywords>
<keywords scheme="MESH" qualifier="physiologie" xml:lang="fr">
<term>Arcade dentaire</term>
<term>Mandibule</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Dental Arch</term>
<term>Mandible</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Mâchoire édentée</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Jaw, Edentulous</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Biomechanical Phenomena</term>
<term>Bite Force</term>
<term>Computer Simulation</term>
<term>Dental Abutments</term>
<term>Dental Implants</term>
<term>Dental Prosthesis, Implant-Supported</term>
<term>Denture, Complete, Lower</term>
<term>Denture, Overlay</term>
<term>Female</term>
<term>Finite Element Analysis</term>
<term>Humans</term>
<term>Middle Aged</term>
<term>Models, Biological</term>
<term>Stress, Mechanical</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte d'âge moyen</term>
<term>Alliages d'or</term>
<term>Analyse des éléments finis</term>
<term>Contrainte mécanique</term>
<term>Femelle</term>
<term>Force occlusale</term>
<term>Humains</term>
<term>Imagerie tridimensionnelle</term>
<term>Implants dentaires</term>
<term>Matériaux dentaires</term>
<term>Modèles biologiques</term>
<term>Overdenture</term>
<term>Phénomènes biomécaniques</term>
<term>Piliers dentaires</term>
<term>Prothèse dentaire complète inférieure</term>
<term>Prothèse dentaire implanto-portée</term>
<term>Résines acryliques</term>
<term>Rétention d'appareil de prothèse dentaire</term>
<term>Simulation numérique</term>
<term>Titane</term>
<term>Tomodensitométrie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Two commonly used attachment systems for implant-retained overdentures are bar and ball systems. The aim of this study was to compare these two types of attachments on the basis of the stresses introduced to the mandibular posterior residual ridge by an overdenture retained by two implants.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">23757462</PMID>
<DateCompleted>
<Year>2015</Year>
<Month>04</Month>
<Day>02</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>25</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1936-7163</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>44</Volume>
<Issue>8</Issue>
<PubDate>
<Year>2013</Year>
</PubDate>
</JournalIssue>
<Title>Quintessence international (Berlin, Germany : 1985)</Title>
<ISOAbbreviation>Quintessence Int</ISOAbbreviation>
</Journal>
<ArticleTitle>The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.</ArticleTitle>
<Pagination>
<MedlinePgn>585-90</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.3290/j.qi.a29753</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">Two commonly used attachment systems for implant-retained overdentures are bar and ball systems. The aim of this study was to compare these two types of attachments on the basis of the stresses introduced to the mandibular posterior residual ridge by an overdenture retained by two implants.</AbstractText>
<AbstractText Label="METHOD AND MATERIALS" NlmCategory="METHODS">A basic model was generated from the data provided by a CT scan of a patient's mandible, the diagnostic casts, and the existing overdenture. Two root-form implants were placed in the anterior mandible. Models were used to simulate two situations: The first model represented an edentulous mandible supporting an overdenture retained by two implants connected with a bar and plastic clip system, and in the second model two ball attachments with nylon caps were used as the retention mechanism. A 35 N vertical load was introduced to the first molar region of each group to simulate the occlusal forces of the maxillary complete denture. The stresses in the mandibular residual ridges under the first molar region were measured using Ansys software.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">The bar-retained overdenture introduced higher stresses to the posterior mandibular residual ridge compared to the ball-retained overdenture (0.4 MPa and 0.1 MPa, respectively).</AbstractText>
<AbstractText Label="CONCLUSION" NlmCategory="CONCLUSIONS">Within the limitations of this study, the ball system was shown to introduce a lower amount of stress to the posterior mandibular residual ridge compared to a bar and clip system.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Dashti</LastName>
<ForeName>Mohammad Hossein</ForeName>
<Initials>MH</Initials>
<AffiliationInfo>
<Affiliation>Department Prosthodontics, Boston University School of Dental Medicine, Boston, MA 02118, USA. mhdashti@bu.edu</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Atashrazm</LastName>
<ForeName>Parsa</ForeName>
<Initials>P</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Emadi</LastName>
<ForeName>Mehdi Imani</ForeName>
<Initials>MI</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Mishaeel</LastName>
<ForeName>Shiva</ForeName>
<Initials>S</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Banava</LastName>
<ForeName>Sepideh</ForeName>
<Initials>S</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D003160">Comparative Study</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Germany</Country>
<MedlineTA>Quintessence Int</MedlineTA>
<NlmUniqueID>0342677</NlmUniqueID>
<ISSNLinking>0033-6572</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D015921">Dental Implants</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D003764">Dental Materials</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D006047">Gold Alloys</NameOfSubstance>
</Chemical>
<Chemical>
<RegistryNumber>D1JT611TNE</RegistryNumber>
<NameOfSubstance UI="D014025">Titanium</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>D</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000180" MajorTopicYN="N">Acrylic Resins</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001696" MajorTopicYN="N">Biomechanical Phenomena</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D001732" MajorTopicYN="N">Bite Force</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003198" MajorTopicYN="N">Computer Simulation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D000044" MajorTopicYN="N">Dental Abutments</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003724" MajorTopicYN="N">Dental Arch</DescriptorName>
<QualifierName UI="Q000502" MajorTopicYN="N">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D015921" MajorTopicYN="Y">Dental Implants</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003764" MajorTopicYN="N">Dental Materials</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019094" MajorTopicYN="Y">Dental Prosthesis, Implant-Supported</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003781" MajorTopicYN="N">Denture Retention</DescriptorName>
<QualifierName UI="Q000295" MajorTopicYN="Y">instrumentation</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003826" MajorTopicYN="N">Denture, Complete, Lower</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D003828" MajorTopicYN="Y">Denture, Overlay</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D020342" MajorTopicYN="Y">Finite Element Analysis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006047" MajorTopicYN="N">Gold Alloys</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D021621" MajorTopicYN="N">Imaging, Three-Dimensional</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="Y">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007575" MajorTopicYN="N">Jaw, Edentulous</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008334" MajorTopicYN="N">Mandible</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="N">diagnostic imaging</QualifierName>
<QualifierName UI="Q000502" MajorTopicYN="Y">physiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008954" MajorTopicYN="N">Models, Biological</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013314" MajorTopicYN="N">Stress, Mechanical</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014025" MajorTopicYN="N">Titanium</DescriptorName>
<QualifierName UI="Q000737" MajorTopicYN="N">chemistry</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D014057" MajorTopicYN="N">Tomography, X-Ray Computed</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="entrez">
<Year>2013</Year>
<Month>6</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2013</Year>
<Month>6</Month>
<Day>13</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2015</Year>
<Month>4</Month>
<Day>4</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">23757462</ArticleId>
<ArticleId IdType="pii">29753</ArticleId>
<ArticleId IdType="doi">10.3290/j.qi.a29753</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Atashrazm, Parsa" sort="Atashrazm, Parsa" uniqKey="Atashrazm P" first="Parsa" last="Atashrazm">Parsa Atashrazm</name>
<name sortKey="Banava, Sepideh" sort="Banava, Sepideh" uniqKey="Banava S" first="Sepideh" last="Banava">Sepideh Banava</name>
<name sortKey="Emadi, Mehdi Imani" sort="Emadi, Mehdi Imani" uniqKey="Emadi M" first="Mehdi Imani" last="Emadi">Mehdi Imani Emadi</name>
<name sortKey="Mishaeel, Shiva" sort="Mishaeel, Shiva" uniqKey="Mishaeel S" first="Shiva" last="Mishaeel">Shiva Mishaeel</name>
</noCountry>
<country name="États-Unis">
<noRegion>
<name sortKey="Dashti, Mohammad Hossein" sort="Dashti, Mohammad Hossein" uniqKey="Dashti M" first="Mohammad Hossein" last="Dashti">Mohammad Hossein Dashti</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Santé/explor/EdenteV2/Data/PubMed/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000890 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd -nk 000890 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Santé
   |area=    EdenteV2
   |flux=    PubMed
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:23757462
   |texte=   The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/PubMed/Checkpoint/RBID.i   -Sk "pubmed:23757462" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/PubMed/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a EdenteV2 

Wicri

This area was generated with Dilib version V0.6.32.
Data generation: Thu Nov 30 15:26:48 2017. Site generation: Tue Mar 8 16:36:20 2022